Fe3Al–Al2O3 double-layer coatings (DC), Fe3Al-Fe3Al/50%Al2O3–Al2O3 triple-layer coatings (TC) and Fe3Al-Al2O3 graded coatings (GC) were produced from a series of Fe3Al/Al2O3 composite powders with different compositions on low carbon steel substrate using PLAXAIR plasma spraying equipment. Friction behaviors and wear resistance of the three kinds of coatings have been investigated under different loads. Tests were carried out using an MRH-3 standard machine, in lineal contact sliding under dry condition against hardmetal, at a sliding velocity of about 1.57 ms−1. Wear rates under different loads were measured and the friction coefficients were recorded. SEM analysis was carried out to identify the wear mechanisms. The results show that the GC has higher wear-resistance than DC and TC. The tribological characteristics of graded coating were different along the depth of the coatings, and the surface of coatings with pure Al2O3 does not show the best wear resistance. The wear rate and friction coefficients were also different under different loads. The failure types of plasma-sprayed Fe3Al-Al2O3 graded coatings in lineal contact were: loosening of ceramic particles, crack nucleation and propagation, brittle fracture, plastic deformation, and adhesive wear.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Low temperature diffusion treatments with nitrogen and carbon have been widely used to increase the tribological performance of austenitic stainless steels. These processes produce a layer of supersaturated austenite, usually called expanded austenite or S-phase, which exhibits good corrosion and wear resistance. The novel active screen technology is said to provide benefits over the conventional DC plasma technology. The improvements result from the reduction in the electric potential applied to the treated components, and the elimination of such defects and processing instabilities as edge effects, hollow cathode effects and arcing. In this study, AISI 316 coupon samples were plasma carburised in DC and active screen plasma furnaces. The respective layers of carbon expanded austenite were characterised and their tribological performance was studied and compared. Detailed post-test examinations included SEM observations of the wear tracks and of the wear debris, EDX mapping of the wear track, EBSD crystal orientation mapping of the cross sections of the wear tracks, and cross-sectional TEM. Based on the results of wear tests and post-test examinations, the wear mechanisms involved are discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work employed a commercial nitrocaburising process to diffuse a coating onto M2 grade high speed tool steel. Properties of the nitrocaburised coating (CN) such as thickness, roughness and hardness were characterised using a variety of techniques including Glow-Discharge Optical Emission Spectrometry (GD-OES) and Scanning Electron Microscopy (SEM). A tribological test has been developed in which two nominally identical crossed cylinders slide over each other under selected test conditions. The test has been employed to investigate the wear performance of both CN coated and uncoated M2 specimens and frictional behaviour of the sliding interface between the tool and a AISI 1019 steel workpiece under unlubricated (dry) and lubricated conditions. Fourier Transform Infrared Spectroscopy (FTIR) was used to monitor the formation of chemical species from the oxidation of lubricant during tribological testing.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Nitrocarburised H13 disks were tested in dry, sliding wear against a stationary ruby ball (pin). Three different 4 h nitrocarburising treatments were compared, using N2/NH3/CO2, N2/NH3/natural gas and N2/NH3 gas mixtures, resulting in compound layers of varying thickness, hardness, porosity and oxide morphology. During mild, oxidative wear, with the formation of abrasive wear debris, the most brittle and oxidised surfaces performed poorly. Polishing to a bright, reflective finish greatly reduced wear. However, the N2/NH3/CO2 sample also frequently maintained a 'very mild' wear regime, owing to the formation of a protective film between the wear surfaces, and resulting in a lowering of the friction coefficient. This treated surface was porous and covered in a complex layer of coarse oxide+epsi-carbonitride. Nitrocarburised samples and wear tracks were characterised by optical microscopy, SEM, atomic force microscopy and stylus profilometry.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper discusses our recent research on wear at the die radius in sheet metal stamping. According to wear theory, contact pressure and sliding distance are the two dominant factors in determining sliding wear. We applied the finite element analysis to accurately quantify the contact pressure and sliding distance at the die radius in sheet metal stamping. The results were then applied to analyze sliding wear at the die radius. We found that a typical two-peak steady-state contact pressure response exists during a channel forming process. The steady-state contact pressure response was preceded by an initial transient response, which produced extremely large and localized contact pressures. We proposed a method to numerically quantify the sliding distance, which was applied to examine the contact sliding distance at the die radius. Correlating the contact pressure and sliding distance, a new insight into the wear/galling that occurs at the die radius in sheet metal stamping was gained. The results show that the region close to zero degrees on the die radius is likely to experience the most wear, with the identified transient stage contributing to a large proportion of the total wear.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

AISI H13 tool steel discs were pulsed plasma nitrided during different times at a constant temperature of 400 °C. Wear tests were performed in order to study the acting wear mechanisms. The samples were characterized by X-ray diffraction, scanning electron microscopy and hardness measurements. The results showed that longer nitriding times reduce the wear volumes. The friction coefficient was 0.20 ± 0.05 for all tested conditions and depends strongly on the presence of debris. After wear tests, the wear tracks were characterized by optical and scanning electron microscopy and the wear mechanisms were observed to change from low cycle fatigue or plastic shakedown to long cycle fatigue. These mechanisms were correlated to the microstructure and hardness of the nitrided layer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the current work, two different coatings, nitrocarburised (CN) and titanium carbonitride (TiCN) on M2 grade high speed tool steel, were prepared by commercial diffusion and physical vapour deposition (PVD) techniques, respectively. Properties of the coating were characterised using a variety of techniques such as Glow-Discharge Optical Emission Spectrometry (GD-OES) and Scanning Electron Microscopy (SEM). Three non-commercial, oil-based lubricants with simplified formulations were used for this study. A tribological test was developed in which two nominally geometrically-identical crossed cylinders slide over each other under selected test conditions. This test was used to evaluate the effectiveness of a pre-applied lubricant film and a surface coating for various conditions of sliding wear. Engineered surface coatings can significantly improve wear resistance of the tool surface but their sliding wear performances strongly depend on the type of coating and lubricant combination used. These coating-lubricant interactions can also have a very strong effect on the useful life of the lubricant in a tribological system. Better performance of lubricants during the sliding wear testing was achieved hen used with the nitrocarburised (CN) coating. To understand the nature of the interactions and their possible effects on the coating-lubricant system, several surface analysis techniques were used. The molecular level investigation of Fourier Transform Infrared Spectroscopy (FTIR) revealed that oxidative degradation occurred in all used oil-based lubricants during the sliding wear test but the degradation behaviour of oil-based lubricants varied with the coating-lubricant system and the wear conditions. The main differences in the carbonyl oxidation region of the FTIR spectra (1900-1600 cm-1) between different coating-lubricant systems may relate to the effective lifetime of the lubricant during the sliding wear test. Secondary Ion Mass Spectrometry (SIMS) depth profiling shows that the CN coating has the highest lubricant absorbability among the tested tool surfaces. Diffusion of chlorine (C1), hydrogen (H) and oxygen (O) into the surface of subsurface of the tool suggested that strong interactions occurred between lubricant and tool surface during the sliding wear test. The possible effects of the interactions on the performance of whole tribological system are also discussed. The study of Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS) indicated that the envelope of hydrocarbons (CmHn) of oil lubricant in the positive TOF-SIMS spectra shifted to lower mass fragment after the sliding wear testing due to the breakage of long-chain hydrocarbons to short-chain ones during the degradation of lubricant. The shift of the mass fragment range of the hydrocarbon (CmHn) envelope caries with the type of both tool surface and lubricant, again confirming that variation in the performance of the tool-lubricant system relates to the changes in surface chemistry due to tribochemical interactions at the tool-lubricant interface under sliding wear conditions. The sliding wear conditions resulted in changes not only in topography of the tool surface due to mechanical interactions, as outlined in Chapter 5, but also in surface chemistry due to tribochemical interactions, as discussed in Chapters 6 and 7.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The demand to reduce the use of lubricants and increase tool life in sheet metal stamping has resulted in increased research on the sliding contact between the tool and the sheet materials. Unlubricated sliding wear tests for soft carbon steel sliding on D2 tool steel were performed using a pin-on-disk tribometer. The results revealed that temperature has an influencing role in the wear of tool steel and that material transfer between tool and sheet can be minimized at a certain temperature range in sheet metal stamping.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Surface mechanical attrition treatment (SMAT), a novel surface severe plastic deformation method, was carried out for titanium (Ti) to create a gradient-structured Ti (SMAT Ti). The tribological behaviour was studied under different loads and dry sliding conditions. The results showed that the deformation layer of SMAT Ti was about 160 μm. The friction and wear results showed that the wear resistance of SMAT Ti was enhanced compared to the coarse-grained (CG) counterpart. SMAT Ti showed abrasive wear under 1 and 5 N, and exhibited abrasive and adhesive wear under 2 N. While CG Ti showed abrasive and adhesive wear under 1-2 N, and exhibited abrasive wear under 5 N for the work hardening effects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Titanium and its alloys are excellent candidates for biomedical implant. However, they exhibit relatively poor tribological properties. In this study, a two-step treatment including surface mechanical attrition treatment (SMAT) combined with thermal oxidation process has been developed to improve the tribological properties and biocompatibility of Ti. Ti after two-step treatment shows excellent wear-resistance and biocompatibility among all Ti samples, which can be ascribed to the highest surface energy, well crystallinity of rutile layer on its surface. Overall, the two-step treatment is a prospective method to produce excellent biomedical Ti materials.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper directly examines the contact sliding distance experienced during a typical sheet metal stamping process-an area that has largely been neglected in the literature. A method to numerically quantify the sliding distance is proposed. The sliding distance predicted from this method, and the contact pressure obtained from numerical simulation, allow the recently identified time-dependent contact conditions on the die and blank surfaces to be completely characterized. Consequently, a new insight into the wear/galling that occurs at the die radius in sheet metal stamping is gained. The results show that the region close to zero degrees on the die radius is likely to experience the most wear, with the identified transient stage contributing to a large proportion of the total wear. Additionally, the region on the blank surface often observed to be heavily burnished - the die impact line - is estimated to experience the highest wear severity due to the transient contact conditions. The proposed method to numerically quantify the sliding contact conditions can be applied as a general approach to study any other two-body sliding contact situations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study examines the effect of sliding speed and surface temperature on the wear behavior of an unlubricated mild steel-tool steel contact pair using the pin-on-disc test. The operating conditions and contact pair are of interest to the automotive sheet metal stamping industry and the broader metal forming community, where high contact pressures and moderate forming speeds can result in significant frictional heating and thus affect tool life. It will be shown that, while adhesive wear is dominant at the tool steel surface for all sliding speeds examined, the adhesive wear rate is very sensitive to sliding speed during slow speed conditions but relatively insensitive to sliding speed during higher speed conditions. These higher sliding speeds result in high frictional heating, however, the effect of increasing bulk temperature results in a transition from adhesive wear to material removal-dominated mechanisms. It is concluded that there is a distinct difference in the wear response for comparable surface temperature and bulk temperature conditions, at the low to moderate sliding speeds and temperatures examined in this study. The SEM and profilometry analysis show that the technique of increasing sliding speed to replicate bulk temperature conditions (or vice versa), may not result in equivalent wear rates and mechanisms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The conventional approach ie laboratory life testing to examine the reliability of products takes long time and involves tremendous cost as samples are tested till failures. The accelerated life test (ALT) has recently been used as an alternative method. Although ALT reduces the cost of reliability testing through applying more severe environmental conditions than the normal ones, it is no longer sufficient as it does not describe the process of products’ failure explicitly and it is still highly dependent on physical testing. Consequently, novel practices need to be developed for better understanding of the products’ reliability. A novel Finite Element Analysis (FEA) model incorporating mathematical wear equations is developed in the current work and applied to polymer materials. Wear rate, a key parameter, is calculated by using a combinatorial formula that combines a conventional linear equation with a recently published exponential equation. The local wear is firstly calculated and then integrated over the sliding distance. The FEA simulation works in a loop and performs a series of simulation with updated surface geometries. The simulation is in good agreement with the physical testing result.