113 resultados para rigenerazione, riqualificazione, comfort, efficienza, sostenibilità, edilizia,

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This note is directed to one major aspect of the comfort of building occupants &ndash; namely, thermal comfort. Even though it may be difficult to isolate thermal sensations from the whole of comfort itself, humans have a strong physiological connection with their thermal environment. Our thermal perceptions and sensations often vary greatly, especially between our indoor and outdoor environments. We may be totally comfortable lounging under a shade cloth on a 35&deg;C day with a stiff breeze enveloping our body, but would never tolerate similar conditions indoors. Such divergent perceptions of the same thermal stimulus across differing contexts raise countless questions about just what the determinants of thermal comfort actually are, and how they may be managed against the demands for an environmentally responsive architecture. <br />

Relevância:

20.00% 20.00%

Publicador:

Resumo:

<b>Study objective: </b>To compare three dressing types in terms of their ability to protect against infection and promote healing, patient comfort, and cost-effectiveness.<br /><br /><b>Design: </b>Prospective, randomized controlled trial.<br /><br /><b>Setting: </b>Major metropolitan, academically affiliated, tertiary referral center.<br /><br /><b>Patients: </b>Seven hundred thirty-seven patients were randomized to receive a dry absorbent dressing (n = 243) [Primapore; Smith &amp; Nephew; Sydney, NSW, Australia], a hydrocolloid dressing (n = 267) [Duoderm Thin ConvaTec; Mulgrave, VIC, Australia], or a hydroactive dressing (n = 227) [Opsite; Smith &amp; Nephew] in the operating theater on skin closure.<br /><br /><b>Results: </b>There was no difference in the rate of wound infection or wound healing between treatment groups. The Primapore dressing was the most comfortable and cost-effective dressing option for the sternotomy wound. Duoderm Thin dressings were associated with increased wound exudate (p &lt; 0.001), poor dressing integrity (p &lt; 0.001), more frequent dressing changes (p &lt; 0.001), more discomfort with removal (p &lt; 0.05), and increased cost (p &lt; 0.001).<br /><br /><b>Conclusions:</b> In the context of no additional benefit for the prevention of wound infection or the rate of wound healing for any of the three dressing products examined, dry absorbent dressings are the most comfortable and cost-effective products for sternotomy wounds following cardiac surgery.<br />

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The topic of &ldquo;comfort letters&rdquo; is an ongoing debate in Australia. There are arguments for and against enforceability of comfort letters, yet little has been said about how the &ldquo;law&rdquo; can be reformed. In support of enforceability, this article provides a comparative perspective on the American and Australian models and suggests that certain principles from the former could be adopted in Australia to eliminate the inconsistency in the treatment of comfort letter cases. The article also analyses Gate Gourmet and Lasalle Bank, two recent cases from Australia and the United States, respectively.<br />

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the concept and a test implementation of a digital representation of the physical world designed to assess comfort quality in<br />future environments. An integrated set of physical phenomena is modeled three-dimensionally to investigate the dynamic behavior of design objects<br />holistically.<br /><br />The formulation supports the integration of computational simulation in the performance-based design process. It employs the principles of<br />geometrical and physical selfcontainedness to avoid that complex geometrical and physical circumstances have to be specified at design time. The concepts of congeneric cells and congeneric conjunctions are<br />introduced to simulate various physical phenomena simultaneously with a uniformly structured set of equations.<br /><br />The concept, the prototype implementation and selected test cases are presented. Although it was not possible to implement all features and model parts completely, the research and the discussion of its achievements make valuable contributions towards more effective integration of computational simulation in the performance-based design process.<br />

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reviews the evolution of Fanger's heat balance equation in regard of adaptive opportunities. Heat balance and adaptive response are integrated into one model as two fundamental aspects of human-environment interaction that define thermal comfort perception, rather than being seen as two concepts of alternative comfort paradigms. The paper suggests to extent Fanger's model with a heat storage term in order to account for comfort perception under transient thermal conditions, and to review Fanger's modelling assumptions in order to allow for a greater variety of adaptive response options. In the presented model heat exchange is modulated through adaptation of physiological, environmental and behavioural parameters in the human-environment system defined through Fanger's heat exchange equations. A computational prototype is implemented to determine 'comfortable' values and ranges of the six comfort dimensions alternatively to Fanger's comfort indices. Thereby values of for example 'comfortable' clothing and metabolic rate are results rather than necessary input parameters, which are difficult to determine. This approach allows generating design advice for physical, organisational and social environments based on heat balance calculation in the six-dimensional opportunity space defined through Fanger's comfort equation. A starting point for the development of a dynamic adaptive comfort model is set.<br />

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the exploration and the development of computational means to investigate the behaviour of design objects before they are available for investigation in the physical world. The motivation is to inform the design process about the design object's performance in order to achieve better--more performance-oriented--design outcomes in the sense of energy efficiency and comfort performance than can be achieved by conventional design techniques. <br />

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A two-storey rammed earth building was built on the Thurgoona Campus of Charles Sturt University in Albury-Wodonga, Australia, in 1999. The building is novel both in the use of materials and equipment for heating and cooling. The climate at Wodonga can be characterised as hot and dry, so the challenge of providing comfortable working conditions with minimal energy consumption is considerable. This paper describes an evaluation of the building in terms of measured thermal comfort and energy use. Measurements, confirmed by a staff questionnaire, found the building was too hot in summer and too cold in winter. Comparison with another office building in the same location found that the rammed earth building used more energy for heating. The thermal performance of three offices in the rammed earth building was investigated further using simulation to predict office temperatures. Comparisons were made with measurements made over typical weeks in summer and winter. The validated model has been used to investigate key building parameters and strategies to improve the thermal comfort and reduce energy consumption in the building. Simulations showed that improvements could be made by design and control strategy changes.<br />

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Humla Province is a remote mountainous region of northwest Nepal. The climate is harsh and the local people are extremely poor. Most people endure a subsistence culture, living in traditional housing. Energy for cooking and heating comes from fuelwood, supplies of which are diminishing. In order to improve the indoor environment and reduce fuelwood use, smokeless stoves are being introduced to replace the open fire in Humli homes. There is some concern, however, that comfort levels may not be as acceptable with these stoves. The aim of this research was therefore to investigate ways in which the comfort levels in traditional Humli housing might be improved using simple and low cost strategies. Temperature data was recorded in four rooms of a traditional Humli home over a 12-day period and used with fuelwood data to validate a TRNSYS simulation model of the house. This model was then used to evaluate the impact on comfort levels in the house of various energy conservation strategies using PMV and PPD indicators. As a single strategy, it was found that reducing infiltration of outside air was likely to be more effective than increasing the insulation level in the ceilings. The most successful strategy, however, was the creation of sunspaces at the entrances to the living rooms. This strategy increased average internal temperatures by 1.7 and 2.3 &deg;C. In combination with increased insulation levels, the sunspaces reduced comfort dissatisfaction levels by over 50%.<br />

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Darwin`s climate is hot and humid and as a result the use of residential air-conditioners is high. Although this technology allows the occupant to achieve thermal comfort, its use contributes directly to an increase in the emission of greenhouse gases. More environmentally-friendly ways of achieving residential thermal comfort in this climate need to be investigated. One method is to improve the home`s passive design. The aim of this research was to increase the thermal comfort of typical Darwin homes without the use of air conditioning. Temperature data from two houses (lightweight elevated and concrete) was recorded over a nine-day period and used to validate a TRNSYS simulation model of each house. Simulations were run using these validated models and three months of climatic data (January&mdash;March) to evaluate various passive design strategies. The success of three strategies was analysed using PMV and PPD indicators. As a single strategy, it was found that ventilation and air velocity by far increased the level of thermal comfort for occupants of both houses. Although the passive design strategies of increased shading and insulation were beneficial, Darwin`s ovemight low temperature and humidity are still too high to reduce these levels within the house significantly without air conditioning.<br />

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Legislation is demanding that our existing building stock be improved to a minimum of 4.0 Star AGBRS (Aust. Green Building Rating Scheme) energy standards. In the 'Green Building Fund' scheme for office buildings and other government incentives, retrofitting our existing building stock makes plain good sense. However, many of the stakeholders (owners, facilities managers, occupants) do not know where to begin to invest, for making these savings. This paperdemonstrates through two case studies, in government related&nbsp; office buildihgs,how real energy savings were approached and obtained. It illustrates a process whereby preliminary and pretesting results lead to solutions of building ventilation, infiltration and comfort improvement. Furthermore, it discusses how post building performance testing results verified improvement as well as provided inputs to energy simulation, indicating where further invested improvements could be made.<br />One case study illustrates how the weatherisation of a building prevented a 1.5 million dollar retrofitting spending, costing the client less than one-tenth of the initial retrofitting cost. Another example demonstrates how over-engineering and incorrect ventilation concepts can cost the client up to 70% of their energy bill. Both papers involve real evidence-based pre and post measurement results in existing occupied buildings.<br />

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analysis was made of the Charles Sturt University Academic Office building at Thurgoona from a thermal comfort and energy viewpoint. It was found that the offices did not meet low energy criteria and some were uncomfortable for 30% to 85% of occupied hours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change (IPCC), the construction sector has the greatest potential for climate change mitigation. This work investigates the potential for climate change mitigation in naturally ventilated and mixed mode office buildings, by evaluating the range of influence of building design and occupants on greenhouse gas emissions as well as thermal and visual comfort.<br /><br />Thermal comfort is evaluated according to the EN 15251 adaptive thermal comfort model, visual comfort is based on daylight autonomy and view. Parametric studies have been conducted based on building simulation for the climate of Athens, Greece. Input data are based on a literature review, and on results from a field study conducted among office occupants and architects in Athens.<br /><br />The results show that the influence of occupants on greenhouse gas emissions is larger than the influence of building design. Energy saving office equipment, as well as active use of building controls for shading and lighting by occupants are crucial parameters regarding the reduction of CO2 emissions. In mixed mode buildings, the coefficient of performance of the cooling system is an important parameter as well. Regarding thermal and visual comfort, the influence of building design is predominant. A green building, well protected against heat from the sun and able to balance solar and internal heat gains, provides higher comfort levels and is less affected by the influence of occupants. In mixed mode buildings, building design is the predominant influence on the magnitude of cooling loads. A hot summer including heat waves can significantly reduce thermal comfort and increase the resulting greenhouse gas emissions. Green buildings are least affected by these influences.<br /><br />The EN 15251 adaptive thermal comfort model provides a thermal comfort evaluation method valid throughout Europe. However, for the Mediterranean climate of Athens, Greece, most of the configurations investigated within this study do not meet the requirements according to this model. EN 15251 refers to an adaptive thermal comfort model for naturally ventilated and to a static model for mechanically ventilated buildings. For mixed mode buildings, the static model is recommended, but literature indicates that occupants in those buildings might be more tolerant towards higher temperatures. The hypothetical application of the EN 15251 adaptive thermal comfort model in mixed mode offices, as investigated in this study, shows potential for greenhouse gas emission savings. However, this influence is small compared to that of building design and occupants. Conclusions are drawn regarding the categorisation and exceeding criteria according to EN 15251 adaptive thermal comfort model for offices in a Mediterranean climate.<br /><br />The results of this work show, that not only green buildings, but also green occupants can significantly contribute to the mitigation of the climate change. Mechanisms of the real estate market as well as the lifestyle of occupants are important influences in this context. Sustainability therefore refers to finding the right balance between occupant&rsquo;s comfort expectations and resulting greenhouse gas emissions for a specific building, rather than optimisation of single parameters<br />