33 resultados para photovoltaic system

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to the increasing world energy demand, renewable energy systems have been significantly applied in the power generation sector. Among the renewable energy options, photovoltaic system is one of the most popular resources which has been experiencing a huge attention during recent decades. The remarkable advantages, such as static and movement free characteristics, low maintenance costs, and longevity are the primary factors for the popularity of solar generation in the late years. Nevertheless, the low PV conversion efficiency in one side and high PV material cost in the other side have made PV generation comparably expensive system. Consequently, a capable maximum power point tracking (MPPT) is all important to elicit the maximum energy from the production of PV systems. Different researches have been conducted to design a fast, simple and robust MPPT technique under uniform conditions. However, due to the series and parallel connection of PV modules and according to the use of bypass diodes, in the structure of PV modules, a conventional techniques are unable to track a true MPP. Recently, several studies have been undertaken to modify these conventional methods and enable them to track the global MPP under rapidly changing environments and partial shading (PS) conditions. This report concentrates on the state of the art of these methods and their evolution to apply under PS conditions. The recent developments and modifications are analyzed through a comparison based on design complexity, cost, speed and the ability to track the MPP under rapid environmental variations and PS conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, simulation and hardware implementation of Fuzzy Logic (FL) Maximum Power Point Tracking (MPPT) used in photovoltaic system with a direct control method are presented. In this control system, no proportional or integral control loop exists and an adaptive FL controller generates the control signals. The designed and integrated system is a contribution of different aspects which includes simulation, design and programming and experimental setup. The resultant system is capable and satisfactory in terms of fastness and dynamic performance. The results also indicate that the control system works without steady-state error and has the ability of tracking MPPs rapid and accurate which is useful for the sudden changes in the atmospheric condition. MATLAB/Simulink software is utilized for simulation and also programming the TMS320F2812 Digital Signal Processor (DSP). The whole system designed and implemented to hardware was tested successfully on a laboratory PV array. The obtained experimental results show the functionality and feasibility of the proposed controller.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Partial shading is an unavoidable condition which significantly reduces the efficiency and stability of a photovoltaic (PV) system. When partial shading occurs the system has multiple-peak output power characteristics. In order to track the global maximum power point (GMPP) within an appropriate period a reliable technique is required. Conventional techniques such as hill climbing and perturbation and observation (P&O) are inadequate in tracking the GMPP subject to this condition resulting in a dramatic reduction in the efficiency of the PV system. Recent artificial intelligence methods have been proposed, however they have a higher computational cost, slower processing time and increased oscillations which results in further instability at the output of the PV system. This paper proposes a fast and efficient technique based on Radial Movement Optimization (RMO) for detecting the GMPP under partial shading conditions. The paper begins with a brief description of the behavior of PV systems under partial shading conditions followed by the introduction of the new RMO-based technique for GMPP tracking. Finally, results are presented to demonstration the performance of the proposed technique under different partial shading conditions. The results are compared with those of the PSO method, one of the most widely used methods in the literature. Four factors, namely convergence speed, efficiency (power loss reduction), stability (oscillation reduction) and computational cost, are considered in the comparison with the PSO technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the control and charge management strategy of a photovoltaic system (PV) with plug-in hybrid electric vehicle (PHEV) as energy storage. The hybrid energy storage system (HESS) of PHEV consists of battery and supercapacitor. A simulation model for the PV system with PHEV energy storage has been developed using Matlab/SimpowerSystems. The system consists of PV arrays, SEPIC dc-dc converter with maximum power point tracking (MPPT), hybrid battery-supercapacitor energy storage with bidirectional dc-dc converter and inverter for grid connection. A charge management algorithm for the hybrid energy storage system is proposed to control the power flows among the PV system, energy storage and the grid. Results show that the proposed power management algorithm can control the power flows in an efficient manner.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a μ-Synthesis H∞ Controller for regulating the switching signal of the inverter connected with a three-phase photovoltaic (PV) system. To facilitate the control design, the system is represented in terms of state space realization with uncertainties. The control design involves selecting proper weighting functions and performing synthesis. The controller order is reduced by Henkel-norm method. Simulations are carried out to evaluate the characteristics of the controller under parametric uncertainties. It is found out that the proposed controller is inherently stable, possesses significantly small tracking error, and preserves nominal performance, robust stability and robust performance for the grid-connected three-phase PV system.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A mathematical model of a solar module is presented. This model takes into account solar model temperature and solar radiation. The experimental data of a solar module under natural environment condition (NEC) have been obtained to determine the model parameters. The experimental results are compared with those calculated by using a mathematical model. It shows that the mathematical model accurately simulates the current-voltage characteristics of the solar module under the NEC and therefore is suitable for photovoltaic system design and performance analysis.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

As of today, the considerable influence of select environmental variables, especially irradiance intensity, must still be accounted for whenever discussing the performance of a solar system. Therefore, an extensive, dependable modeling method is required in investigating the most suitable Maximum Power Point Tracking (MPPT) method under different conditions. Following these requirements, MATLAB-programmed modeling and simulation of photovoltaic systems is presented here, by focusing on the effects of partial shading on the output of the photovoltaic (PV) systems. End results prove the reliability of the proposed model in replicating the aforementioned output characteristics in the prescribed setting. The proposed model is chosen because it can, conveniently, simulate the behavior of different ranges of PV systems from a single PV module through the multidimensional PV structure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The impacts on the environment from human activities are of increasing concern. The need to consider the reduction in energy consumption is of particular interest, especially in the construction and operation of buildings, which accounts for between 30 and 40% of Australia's national energy consumption. Much past and more recent emphasis has been placed on methods for reducing the energy consumed in the operation of buildings. With the energy embodied in these buildings having been shown to account for an equally large proportion of a building's life cycle energy consumption, there is a need to look at ways of reducing the embodied energy of buildings and related products. Life cycle assessment (LCA) is considered to be the most appropriate tool for assessing the life cycle energy consumption of buildings and their products. The life cycle inventory analysis (LCIA) step of a LCA, where an inventory of material and energy inputs is gathered, may currently suffer from several limitations, mainly concerned with the use of incomplete and unreliable data sources and LCIA methods. These traditional methods of LCIA include process-based and input-output-based LCIA. Process-based LCIA uses process specific data, whilst input-output-based LCIA uses data produced from an analysis of the flow of goods and services between sectors of the Australian economy, also known as input-output data. With the incompleteness and unreliability of these two respective methods in mind, hybrid LCIA methods have been developed to minimise the errors associated with traditional LCIA methods, combining both process and input-output data. Hybrid LCIA methods based on process data have shown to be incomplete. Hybrid LCIA methods based on input-output data involve substituting available process data into the input-output model minimising the errors associated with process-based hybrid LCIA methods. However, until now, this LCIA method had not been tested for its level of completeness and reliability. The aim of this study was to assess the reliability and completeness of hybrid life cycle inventory analysis, as applied to the Australian construction industry. A range of case studies were selected in order to apply the input-output-based hybrid LCIA method and evaluate the subsequent results as obtained from each case study. These case studies included buildings: two commercial office buildings, two residential buildings, a recreational building; and building related products: a solar hot water system, a building integrated photovoltaic system and a washing machine. The range of building types and products selected assisted in testing the input-output-based hybrid LCIA method for its applicability across a wide range of product types. The input-output-based hybrid LCIA method was applied to each of the selected case studies in order to obtain their respective embodied energy results. These results were then evaluated with the use of a number of evaluation methods. These evaluation methods included an analysis of the difference between the process-based and input-output-based hybrid LCIA results as an evaluation of the completeness of the process-based LCIA method. The second method of evaluation used was a comparison between equivalent process and input-output values used in the input-output-based hybrid LCIA method as a measure of reliability. It was found that the results from a typical process-based LCIA and process-based hybrid LCIA have a large gap when compared to input-output-based hybrid LCIA results (up to 80%). This gap has shown that the currently available quantity of process data in Australia is insufficient. The comparison between equivalent process-based and input-output-based LCIA values showed that the input-output data does not provide a reliable representation of the equivalent process values, for material energy intensities, material inputs and whole products. Therefore, the use of input-output data to account for inadequate or missing process data is not reliable. However, as there is currently no other method for filling the gaps in traditional process-based LCIA, and as input-output data is considered to be more complete than process data, and the errors may be somewhat lower, using input-output data to fill the gaps in traditional process-based LCIA appears to be better than not using any data at all. The input-output-based hybrid LCIA method evaluated in this study has shown to be the most sophisticated and complete currently available LCIA method for assessing the environmental impacts associated with buildings and building related products. This finding is significant as the construction and operation of buildings accounts for a large proportion of national energy consumption. The use of the input-output-based hybrid LCIA method for products other than those related to the Australian construction industry may be appropriate, especially if the material inputs of the product being assessed are similar to those typically used in the construction industry. The input-output-based hybrid LCIA method has been used to correct some of the errors and limitations associated with previous LCIA methods, without the introduction of any new errors. Improvements in current input-output models are also needed, particularly to account for the inclusion of capital equipment inputs (i.e. the energy required to manufacture the machinery and other equipment used in the production of building materials, products etc.). Although further improvements in the quantity of currently available process data are also needed, this study has shown that with the current available embodied energy data for LCIA, the input-output-based hybrid LCIA appears to provide the most reliable and complete method for use in assessing the environmental impacts of the Australian construction industry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Intergovernmental Panel on Climate Change and the McKinsey Greenhouse Gas abatement studies have highlighted reduction of building energy consumption as a primary cost-effective element in the abatement of Global Warming. Nevertheless, the energy investigation in most of our existing building stock remains at a novice level at best. Building sub-metering, by which we mean any secondary, hourly, metering (after the main) of various circuits, provides substantial information on when and where energy is used in specific buildings. Furthermore, combining this information with external weather data provides information beyond basic metering results. This paper discusses three case studies and explains how sub-metering, augmented by external solar and temperature data, benefits energy management and identified problems. It explains how different methods of analysing energy usage allowed: justifiable sizing of a solar photovoltaic system, with a calculated Cooling Degree Unit, identified the absence of savings from a proprietary chiller controller, and the energy variation due to user schedules and external conditions indicated anomalies in energy use. The advantages of wireless access are noted. Extracting information in graphical formats suggests better strategies to understand and control energy use.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a robust nonlinear distributed controller design for islanded operation of microgrids in order to maintain active and reactive power balance. In this paper, microgrids are considered as inverter-dominated networks integrated with renewable energy sources (RESs) and battery energy storage systems (BESSs), where solar photovoltaic generators act as RESs and plug-in hybrid electric vehicles as BESSs to supply power into the grid. The proposed controller is designed by using partial feedback linearization and the robustness of this control scheme is ensured by considering structured uncertainties within the RESs and BESSs. An approach for modeling the uncertainties through the satisfaction of matching conditions is also provided in this paper. The proposed distributed control scheme requires information from local and neighboring generators to communicate with each other and the communication among RESs, BESSs, and control centers is developed by using the concept of the graph theory. Finally, the performance of the proposed robust controller is demonstrated on a test microgrid and simulation results indicate the superiority of the proposed scheme under different operating conditions as compared to a linear-quadratic-regulator-based controller.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Using renewable energy sources for onsite cogeneration from structural building elements is a relatively new concept and is gaining considerable interest. In this study the design, development, manufacturing and testing of a novel building integrated photovoltaic/thermal (BIPVT) solar energy cogeneration system is discussed.

Adhesives (ADH), resistance seam welding (RSW) and autoclaving (ATC) were identified as the most appropriate for fabricating BIPVT roofing panels. Of these manufacturing methods ADH was found to be most suitable for low volume production systems due to its low capital cost.

A prototype panel, fabricated using ADH methods, exhibited good thermal performance. It was also shown that BIPVT performance could be theoretically predicted using a one dimensional heat transfer model and showed excellent agreement with experimental data. The model was used to suggest further design improvements. Finally, a transient simulation of the BIPVT was performed in TRNSYS and is used to illustrate the benefits of the system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Building integrated photovoltaic (BiPV) systems generate electricity, but also heat, which is typically wasted and also reduces the efficiency of generation. A heat recovery unit can be combined with a BiPV system to take advantage of this waste heat, thus providing cogeneration. Two different photovoltaic (PV) cell types were combined with a heat recovery unit and analysed in terms of their life-cycle energy consumption to determine the energy payback period. A net energy analysis of these PV systems has previously been performed, but recent improvements in the data used for this study allow for a more comprehensive assessment of the combined energy used throughout the entire life-cycle of these systems to be performed. Energy payback periods between 4 and 16.5 years were found, depending on the BiPV system. The energy embodied in PV systems is significant, emphasised here due to the innovative use of national average input–output (I–O) data to fill gaps in traditional life-cycle inventories, i.e. hybrid analysis. These findings provide an insight into the net energy savings that are possible with a well-designed and managed BiPV system.