9 resultados para natural ventilation

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the feasibility study on the application of passive and active stack systems to enhance natural ventilation in public housing in Singapore. About 86% of the population is staying in high-rise public housing, known as Housing and Development Board (HDB) flats, which is designed for natural ventilation. The primary objective of this work is to assess the status of natural ventilation in a typical four-room HDB flat using scaled model in the wind tunnel, and to develop an effective passive or active stack system to enhance natural ventilation in the flat. Four numbers of stacks with different sizes were tested at two locations in the flat. The study shows that the passive stack, incorporating the principle of airflow due to buoyancy, does not enhance air velocity in the flat. However, the active stack which operates based on the suction effect induced by a fan fixed at the top of the stack leads to substantial increase in the air velocity at the room and thus meeting the human’s thermal comfort condition. It was noted that the velocities increase along with the increase in the stack size.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

According to IPCC (Intergovernmental Panel on Climate Change), the largest use of energy in commercial buildings is space heating in colder climates and air conditioning in hot climates. In Europe, the Directive on the energy performance of buildings EPBD (European Energy Performance of Buildings Directive) [1] provides a framework for national building performance regulations and calculation procedures. However, there are often large discrepancies between calculated and measured energy performance of buildings. One main reason is the behaviour of occupants, which is often not reflected in calculation models.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

There has been an increasing demand for sports facilities in urban areas recently. As a result of this, more attention is drawn towards not only the energy performance of these building typologies, but also creating a healthy indoor environment for the users. This Study investigates the thermal and ventilation performance of a sports hall within an aquatic centre using computational fluid dynamics (CFD) simulations. IES Virtual Environment software was used to perform the simulations. A number of scenarios were tested by changing the position of extract fans as well as by incorporating natural ventilation strategies. A high level of discomfort was observed in the space. Better comfort condition was achieved by changing the location of exhaust fans ad openings. The results help to recommend some guidelines to inform the proposed refurbishment plans of the site.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A commercial roller-skating centre in southern Australia had condensation problems on both the roof and floor. The building is a typical warehouse-type structure with a high level of natural ventilation due to poor construction and permanently open vents. A computer model of the building, using the thermal simulation software TRNSYS, was calibrated from a sensitivity analysis of three key parameters, namely air exchange rate, roof surface heat transfer coefficient and deep ground temperature. The predicted times of condensation on the roof were compared with site observations. The time of year was predicted with acceptable accuracy, although earlier in the morning than had been observed. The effect of installing foil insulation in the roof was simulated. Under normal winter conditions, this modification was enough to stop the condensation. However, in unusually cold and humid conditions, condensation still occurred on both surfaces. This was overcome by heating the floor (15 W/m 2 ) for approximately eight hours. Subsequent modifications have demonstrated the value of the simulations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article investigates the context dependency of comfort and energy performance in mixed-mode offices in the climate of Athens, Greece. It is based on a parametric study using the simulation software EnergyPlus. Context refers to different building design priorities on the real estate market (prestige, low cost and green), occupant behaviour scenarios (ideal and worst case) and cooling strategies (fixed and adaptive set points). Results are evaluated according to energy consumption and related greenhouse gas emissions, daylight autonomy, view and percentage of working time when heating and cooling are operating. The results indicate that a holistic approach to comfort and energy performance evaluation focused on the specific context of a building and its occupants is necessary to develop appropriate optimization strategies. In early design stages, such specific information is not yet available and ideal/worst-case scenarios can indicate the magnitude of influence of occupants compared to building design.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Strong heat waves in the past decade and resulting legal cases which gave full responsibility for indoor thermal comfort to building professionals lead to an increased uncertainty how to maintain thermal comfort in offices without the use of a cooling system. Adaptive thermal comfort standards such as EN 15251 and Ashrae Standard 55 provide methodologies to evaluate comfort in naturally ventilated spaces. Based on a parametric study for a typical cellular office in the context of Athens, Greece, and using the building simulation software EnergyPlus, this study investigates the potentials for the applicability of natural ventilation in a Mediterranean climate. The Ashrae Standard 55 and EN 15251 adaptive thermal comfort models are compared in this context, and conclusions are drawn how the use of natural ventilation based on adaptive models can be further encourgaged.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Food security is a significant issue in the remote, high altitude areas of Nepal. Malnutrition is common because the harsh climate restricts production and access to fresh food. Humla is a province in north-west Nepal where the severe weather conditions and limited arable land restrict the growing season of vegetables to only 4-5 months a year. Passive solar greenhouses are a technology that can be used to extend the growing period of vegetables. For the greenhouse to be effective in Humla, the design must be appropriate to the climatic conditions, available resources and the social requirements of the community. This paper describes the design and evaluation of a family-sized solar greenhouse proposed for Humla. Three solar greenhouses built in other high altitude areas have initially been reviewed to see what techniques might be replicated in Humla. The thermal performance of the proposed family-sized greenhouse has been predicted using the solar simulation software, TRNSYS, and compared against an existing design in the area. The proposed design was found to be superior and average night-time temperatures in the coldest month were predicted to be approximately 7°C higher. Overheating was controlled in the hottest month by shading and natural ventilation.