10 resultados para motion measurement

em Deakin Research Online - Australia


Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents an original computational approach to extraction of movie tempo for deriving story sections and events that convey high level semantics of stories portrayed in motion pictures, thus enabling better video annotation and interpretation systems. This approach, inspired by the existing cinematic conventions known as film grammar, uses the attributes of motion and shot length to define and compute a novel continuous measure of tempo of a movie. Tempo flow plots are derived for several full-length motion pictures and edge detection is performed to extract dramatic story sections and events occurring in the movie, underlined by their unique tempo. The results confirm reliable detection of actual distinct tempo changes and serve as useful index into the dramatic development and narration of the story in motion pictures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A platform to move gait analysis, which is normally restricted to a clinical environment in a well-equipped gait laboratory, into an ambulatory system, potentially in non-clinical settings is introduced. This novel system can provide functional measurements to guide therapeutic interventions for people requiring rehabilitation with limited access to such gait laboratories. BioKin system consists of three layers: a low-cost wearable wireless motion capture sensor, data collection and storage engine, and the motion analysis and visualisation platform. Moreover, a novel limb orientation estimation algorithm is implemented in the motion analysis platform. The performance of the orientation estimation algorithm is validated against the orientation results from a commercial optical motion analysis system and an instrumented treadmill. The study results demonstrate a root-mean-square error less than 4° and a correlation coefficient more than 0.95 when compared with the industry standard system. These results indicate that the proposed motion analysis platform is a potential addition to existing gait laboratories in order to facilitate gait analysis in remote locations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An accurate and standardised tool to measure the active range of motion (ROM) of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the hand, possibly increasing the risk of transmitting infections. The system proposed in this paper is the first non-contact measurement system utilising Intel Perceptual Technology and a Senz3D Camera for measuring phalangeal joint angles. To enhance the accuracy of the system, we developed a new approach to achieve the total active movement without measuring three joint angles individually. An equation between the actual spacial position and measurement value of the proximal inter-phalangeal joint was established through the measurement values of the total active movement, so that its actual position can be inferred. Verified by computer simulations, experimental results demonstrated a significant improvement in the calculation of the total active movement and successfully recovered the actual position of the proximal inter-phalangeal joint angles. A trial that was conducted to examine the clinical applicability of the system involving 40 healthy subjects confirmed the practicability and consistency in the proposed system. The time efficiency conveyed a stronger argument for this system to replace the current practice of using goniometers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Direct conversion Doppler radar has the capability to remotely monitor human respiratory activity in a non-contact form. However, the motion or movement from the subject will degrade the acquired respiration signal. As the respiration pattern is one of the essential parameters in respiratory medicine intrinsically containing more information about the respiratory function, it is particularly important to suppress or to separate these motion artefacts in order to reconstruct the corresponding patterns. Experiment results show that EMD-ICA algorithm is capable of separating the mixed respiration signal by recovering the useful information of the breathing pattern as well as the motion signatures using only a single channel measurement when using the source separation algorithm. This reduces the complexity and the cost of the sensing system while removing the undesirable artefacts. A high correlation was also observed from the recovered respiration pattern in comparison to the standard respiration strap for both experiments setup (a seated and a supine position).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives
To elicit descriptive data about limited joint range of motion (ROM) in subjects with type II or III spinal muscular atrophy (SMA) and to examine the relation between the number of motions with limited range and both age and functional ability.
Design
Descriptive cross-sectional study.
Setting
Neurologic pediatric outpatient clinic at a hospital in Taiwan.
Participants
Twenty-seven subjects with SMA type II (mean age, 9.8±6.5y) and 17 with SMA type III (mean age, 12.2±8.7y).
Intervention
Measurement with transparent goniometers of joint ROM bilaterally of the shoulder, elbow, wrist, hip, knee, and ankle.
Main outcome measures
The proportion of participants with each ROM limitation compared with all participants with the same SMA type, age distribution of the participants with each ROM limitation, mean range loss of each motion limitation, and the contracture index (risk index of joint contracture).
Results
Eighty-nine percent of the participants with SMA type II experienced knee extension limitation. Approximately 50% of the participants with both types of SMA had ankle dorsiflexion limitation. The motions of knee and hip extension and ankle dorsiflexion also had a relatively high contracture index. The number of motions with limited range positively correlated (P<.001) with age and upper-extremity functional grade (the higher the functional grade, the poorer the functional ability) for SMA type II.
Conclusions
We found varying degrees of joint ROM limitation. Certain motions were noted to be high risks for the development of contractures. This risk was higher mostly in younger children.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To examine the test–retest reliability and construct validity of cervical active range of motion and isometric neck muscle strength as measured by the Multi Cervical Rehabilitation Unit (Hanoun Medical Inc., Ontario).
Design: A cross-sectional study.
Setting: Institutional practice.
Subjects: Twenty-one patients with neck pain and 25 healthy volunteers.
Methods: After a trial-run session, active range of motion (AROM) was measured in the subsequent two sessions, with 2–3 days in between. During each session, three measurements were taken for each direction (flexion, extension, lateral flexions and rotations). The measurement of isometric strength was after a 15-minute break following completion of the measurement of AROM. Three measurements were made for each of the six directions (flexion, extension, lateral flexions, protraction and retraction). The software of the Multi Cervical Rehabilitation Unit automatically recorded and calculated the maximum AROM and isometric strength.
Results: There was a good to high level of reliability in the measurement of AROM for both groups of subjects, with intraclass correlation coefficients (ICCs) ranging from 0.81 to 0.96. Results also demonstrated very good to excellent reliability in isometric strength measurement (ICCs ranged from 0.92 to 0.99). Moreover, there was a significant difference in isometric neck muscle strength (p = 0.001) and in AROM (p = 0.034) between the two groups.
Conclusions: The Multi Cervical Rehabilitation Unit was found to be reliable and valid for testing the cervical active range of motion and isometric neck muscle strength for both normal and patient subjects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

  Remote human activity monitoring is critical and essential in physiotherapy with respect to the skyrocketing healthcare expenditure and the fast aging population. One of frequently used method to monitor human activity is wearing inertial sensors since it is low-cost and accurate. However, the measurements of those sensors are able only to estimate the orientation and rotation angles with respect to actual movement angles, because of differences in the body’s co-ordination system and the sensor’s co-ordination system. There were numerous studies being conducted to improve the accuracy of estimation, though there is potential for further discussions on improving accuracy by replacing heavy algorithms to less complexity. This research is an attempt to propose an adaptive complementary filter for identifying human upper arm movements. Further, this article discusses a feasibility of upper arm rehabilitation using the proposed adaptive complementary filter and inertial measurement sensors. The proposed algorithm is tested with four healthy subjects wearing an inertial sensor against gold standard, which is the VICON system. It demonstrated root mean squared error of 8.77◦ for upper body limb orientation estimation when compared to gold standard VICON optical motion capture system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper introduces a basic frame for rehabilitation motion practice system which detects 3D motion trajectory with the Microsoft Kinect (MSK) sensor system and proposes a cost-effective 3D motion matching algorithm. The rehabilitation motion practice system displays a reference 3D motion in the database system that the player (patient) tries to follow. The player’s motion is traced by the MSK sensor system and then compared with the reference motion to evaluate how well the player follows the reference motion. In this system, 3D motion matching algorithm is a key feature for accurate evaluation for player’s performance. Even though similarity measurement of 3D trajectories is one of the most important tasks in 3D motion analysis, existing methods are still limited. Recent researches focus on the full length 3D trajectory data set. However, it is not true that every point on the trajectory plays the same role and has the same meaning. In this situation, we developed a new cost-effective method that only uses the less number of features called ‘signature’ which is a flexible descriptor computed from the region of ‘elbow points’. Therefore, our proposed method runs faster than other methods which use the full length trajectory information. The similarity of trajectories is measured based on the signature using an alignment method such as dynamic time warping (DTW), continuous dynamic time warping (CDTW) or longest common sub-sequence (LCSS) method. In the experimental studies, we applied the MSK sensor system to detect, trace and match the 3D motion of human body. This application was assumed as a system for guiding a rehabilitation practice which can evaluate how well the motion practice was performed based on comparison of the patient’s practice motion traced by the MSK system with the pre-defined reference motion in a database. In order to evaluate the accuracy of our 3D motion matching algorithm, we compared our method with two other methods using Australian sign word dataset. As a result, our matching algorithm outperforms in matching 3D motion, and it can be exploited for a base framework for various 3D motion-based applications at low cost with high accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, a renewed attention has been drawn into the dart-thrower's motion as the radiocarpal joint is unique to humans and this is believed to have played a pivotal role in human evolution. Considering the importance of the motion and the complexity of the wrist joint, there have been many articles discussing the kinematics behind this movement. CT scan techniques have been used in a number of these research activities. Due to limitations in the speed of the image acquisition, the positions of the wrist were recorded in static postures. To our knowledge, a data acquisition for the motion with realtime capturing has not been reported. This paper presents the use of a 3D vision-based motion capture device. Leap Motion Controller (LMC), for measuring the radiocarpal joint angles during the dart-thrower's motion in a real-time analysis. The practical capability of the LMC in measuring dart-thrower's motion was examined in a trial involving four subjects and the angles were compared to the angles acquired from an inertial measurement unit (IMU). The results confirmed the LMC can successfully be used in the application of measuring radiocarpal kinematics" of dart-thrower's motion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Inertial measurement units (IMU) provide a convenient tool for gait stability assessment. However, it is unclear how various gait characteristics relate to each other and whether gait characteristics can be obtained from resultant acceleration. Therefore, step duration variability was measured in treadmill walking from 39 young ambulant volunteers (age 24.2 [± 2.5] y; height 1.79 [± 0.09] m; mass 71.6 [± 12.0] kg) using motion capture. Accelerations and gyrations were simultaneously recorded with an IMU. Harmonic ratio, maximum Lyapunov exponents, and multiscale sample entropy (MSE) were calculated. Step duration variability was positively associated with MSE with coarseness levels = 3-6 (r = -.33 to -.42, P ≤ .045). Harmonic ratio and MSE with all coarseness levels were negatively associated (r = -.45 to -.57, P ≤ .004). The MSE with coarseness level = 2 was negatively associated with short-term maximum Lyapunov exponents (r = -.32, P = .047). The agreement between resultant and vertical acceleration derived gait characteristics was excellent (ICC = 0.97-0.99). In conclusion, MSE with varying coarseness levels was associated with the other gait characteristics evaluated in the study. Resultant and vertical acceleration derived results had excellent agreement, which suggests that resultant acceleration is a viable alternative to considering the acceleration dimensions independently.