40 resultados para lubrication and lubricants

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using a surface force apparatus, we have measured the normal and friction forces between layers of the human glycoprotein lubricin, the major boundary lubricant in articular joints, adsorbed from buffered saline solution on various hydrophilic and hydrophobic surfaces: i), negatively charged mica, ii), positively charged poly-lysine and aminothiol, and iii), hydrophobic alkanethiol monolayers. On all these surfaces lubricin forms dense adsorbed layers of thickness 60–100 nm. The normal force between two surfaces is always repulsive and resembles the steric entropic force measured between layers of end-grafted polymer brushes. This is the microscopic mechanism behind the antiadhesive properties showed by lubricin in clinical tests. For pressures up to ∼6 atm, lubricin lubricates hydrophilic surfaces, in particular negatively charged mica (friction coefficient μ = 0.02–0.04), much better than hydrophobic surfaces (μ > 0.3). At higher pressures, the friction coefficient is higher (μ > 0.2) for all surfaces considered and the lubricin layers rearrange under shear. However, the glycoprotein still protects the underlying substrate from damage up to much higher pressures. These results support recent suggestions that boundary lubrication and wear protection in articular joints are due to the presence of a biological polyelectrolyte on the cartilage surfaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

 The present study aims to undertake research to improve the properties of vegetable oil based biodegradable lubricants for hydraulic oil applications. Different approaches were explored and adopted to investigate the thermo-oxidative stability, tribological property and corrosion behaviour of biodegradable basestocks as per the ISO 15380 specification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High molecular weight hyaluronic acid (HA) is present in articular joints and synovial fluid at high concentrations; yet despite numerous studies, the role of HA in joint lubrication is still not clear. Free HA in solution does not appear to be a good lubricant, being negatively charged and therefore repelled from most biological, including cartilage, surfaces. Recent enzymatic experiments suggested that mechanically or physically (rather than chemically) trapped HA could function as an “adaptive” or “emergency” boundary lubricant to eliminate wear damage in shearing cartilage surfaces. In this work, HA was chemically grafted to a layer of self-assembled amino-propyl-triethoxy-silane (APTES) on mica and then cross-linked. The boundary lubrication behavior of APTES and of chemically grafted and cross-linked HA in both electrolyte and lipid 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC) solutions was tested with a surface forces apparatus (SFA). Despite the high coefficient of friction (COF) of μ ≈ 0.50, the chemically grafted HA gel significantly improved the lubrication behavior of HA, particularly the wear resistance, in comparison to free HA. Adding more DOPC lipid to the solution did not improve the lubrication of the chemically grafted and cross-linked HA layer. Damage of the underlying mica surface became visible at higher loads (pressure >2 MPa) after prolonged sliding times. It has generally been assumed that damage caused by or during sliding, also known as “abrasive friction”, which is the main biomedical/clinical/morphological manifestation of arthritis, is due to a high friction force and, therefore, a large COF, and that to prevent surface damage or wear (abrasion) one should therefore aim to reduce the COF, which has been the traditional focus of basic research in biolubrication, particularly in cartilage and joint lubrication. Here we combine our results with previous ones on grafted and cross-linked HA on lipid bilayers, and lubricin-mediated lubrication, and conclude that for cartilage surfaces, a high COF can be associated with good wear protection, while a low COF can have poor wear resistance. Both of these properties depend on how the lubricating molecules are attached to and organized at the surfaces, as well as the structure and mechanical, viscoelastic, elastic, and physical properties of the surfaces, but the two phenomena are not directly or simply related. We also conclude that to provide both the low COF and good wear protection of joints under physiological conditions, some or all of the four major components of joints—HA, lubricin, lipids, and the cartilage fibrils—must act synergistically in ways (physisorbed, chemisorbed, grafted and/or cross-linked) that are still to be determined.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to investigate age, menopausal status, and the male partner's sexual function on the sexual function of the menopausal woman. Sexual functioning of 304 women (120 premenopausal, 76 perimenopausal, 108 postmenopausal) aged between 35 and 65 years from a community sample was investigated. Multiple regression analyses found that sexual satisfaction within the relationship was better predicted by age group than by menopausal status. Younger women were more likely to be satisfied with their sexual relationship than older women. Age group was also a better predictor than menopausal status of current frequency of intercourse, with younger women being likely to have more frequent intercourse than older women. Whether a female respondent had experienced a sexual dysfunction was better predicted by menopausal status than by age. Women who were menopausal were more likely to report a sexual problem such as lack of sexual interest, poor lubrication, and failure to have an orgasm. However, age group appeared to be a better predictor of whether the male partner had experienced a sexual dysfunction. Older men were more likely to have experienced failure to have an erection, for example. The findings of this study indicate that age and the sexual function of the partner are important factors to take into consideration when investigating the sexual function of the menopausal woman.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Galvanneal steel is considered to be better for automotive applications than its counterpart, galvanized steel, mainly because of its superior coating and surface properties. Galvanneal steel is produced by hot dipping sheet steel in a bath of molten zinc with small, controlled, levels of aluminium, followed by annealing which creates a Fe-Zn intermetallic layer. This intermetallic layer of the coating improves spot weldability and improves subsequent paint appearance. However, if the microstructure of the coating is not properly controlled and forming parameters are not properly selected, wear of the coating could occur during stamping. Frictional sliding of the sheet between the tool surfaces results in considerable amount of coating loss. An Interstitial Free steel with a Galvanneal coating of nominally 60g/m2 was used for the laboratory experiments. Flat Face Friction (FFF) tests were performed with different forming conditions and lubricants to simulate the frictional sliding in stamping. Glow-Discharge Optical Emission Spectrometry (DG-OES) was used to measure the change in the coating thickness during sliding. Optical microscopy was considered for imaging the surfaces as well as an optical method to compare the changes in the coating thickness during the forming. The change to the Galvanneal coating thickness was found to be a function of forming parameters.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Articular cartilage is an example of a highly efficacious water-based, natural lubrication system that is optimized to provide low friction and wear protection at both low and high loads and sliding velocities. One of the secrets of cartilage's superior tribology comes from a unique, multimodal lubrication strategy consisting of both a fluid pressurization mediated lubrication mechanism and a boundary lubrication mechanism supported by surface bound macromolecules. Using a reconstituted network of highly interconnected cellulose fibers and simple modification through the immobilization of polyelectrolytes, we have recreated many of the mechanical and chemical properties of cartilage and the cartilage lubrication system to produce a purely synthetic material system that exhibits some of the same lubrication mechanisms, time dependent friction response, and high wear resistance as natural cartilage tissue. Friction and wear studies demonstrate how the properties of the cellulose fiber network can be used to control and optimize the lubrication and wear resistance of the material surfaces and highlight what key features of cartilage should be duplicated in order to produce a cartilage-mimetic lubrication system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Changes in the metal-working industry, as a result of new environmental legislation or health and safety initiatives, creates the need for constant re-formulation of soluble cutting fluids. In order for there to be confidence in the product's ability to perform its required function successfully, there must be some clearly defined test methods for assessing machinability. Such a test methodology must provide comprehensive data on the fluid's lubrication and cooling properties, which are likely to occur in application. This paper describes the functions of soluble cutting fluids and discusses ways in which performance has been previously determined. Furthermore, it presents a new method for assessing machinability which is proposed as the basis for the development of a new and universal test protocol.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Today the tool industry on a worldwide basis uses hard, wear-resistant, and low-friction coatings produced by different processes such as electrochemical or electroless methods, spray technologies, thermochemical, chemical-vapor deposition (CVD), and physical vapor deposition (PVD). In the current work, two different coatings, nitrocarburized (CN) and titanium carbonitride (TiCN) on M2-grade tool steel, were prepared by commercial diffusion and PVD techniques, respectively. Properties such as thickness, roughness, and hardness were characterized using a variety of techniques, including glow-discharge optical emission spectrometry (GD-OES) and scanning electron microscopy (SEM). A crossed-cylinders wear-testing machine was used to investigate the performances of both coatings under lubrication. The effect of coatings on the performance of lubricants under a range of wear-test conditions was also examined. Degradation of lubricants during tribological testing was explored by Fourier transform infrared (FTIR) spectroscopy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Investigates the significance and interactive effects of lubricant type, workpiece surface texture and deformation rate under bulk metal, deformation conditions. A novel test rig was developed in conjunction with statistical test techniques. The result of this work identified a cold forming lubrication system with potential economic and environmental advantages over traditional lubrication systems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The effect of ionic liquid (IL) lubrication for aluminium/steel systems is highly dependant on the applied load and the IL structure. This study illustrates that a change in anion of an IL lubricant results in different physicochemical properties that will alter its performance at a given load. As the load is increased there is a shift in lubricant performance and mechanism of the IL. Up to a load of 30 N the lowest wear coefficient was achieved by a phosphonium diphenylphosphate IL, whilst above 30 N a phosphonium bis(trifluoromethanesulfonyl)amide IL was able to form a more tenacious tribolayer that resulted in the lowest wear.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report on the synthesis, characterisation, and physical and tribological properties of halogen-free ionic liquids based on various chelated orthoborate anions with different phosphonium cations, both without halogen atoms in their structure. Important physical properties of the ILs including glass transition temperatures, density, viscosity and ionic conductivity were measured and are reported here. All of these new halogen-free orthoborate ionic liquids (hf-BILs) are hydrophobic and hydrolytically stable liquids at room temperature. As lubricants, these hf-BILs exhibit considerably better antiwear and friction reducing properties under boundary lubrication conditions for steel–aluminium contacts as compared with fully formulated (15W-50 grade) engine oil. Being halogen free these hf-BILs offer a more environmentally benign alternative to ILs being currently developed for lubricant applications.