199 resultados para lens thickness

em Deakin Research Online - Australia


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of rigid materials with high oxygen permeability (Dk) is on the increase, their major benefit being the reduction of hypoxia. However, there is a reluctance to use these materials possibly due to increased surface scratching, reduced wettability, increased deposition, reduced life expectancy and parameter instability. Considering parameter stability, various studies have demonstrated contradictory results or used high Dk materials based on the silicone acrylate polymer. This study was designed to investigate whether the parameters of a high Dk rigid fluorocarbon contact lens material changed during daily wear and extended wear schedules. Thirty five subjects, divided into group groups, Group I wore the lens on a daily wear basis, whereas those in Group II wore the lens on a monthly extended wear basis. The parameters and integrity of the lenses were monitored in both groups every 3 months. For lens integrity a statistically significant increase in surface scratching was demonstrated for the lenses worn by the subjects of both groups over the time of the study (Group I, F=7.990, P <0.0001 [ANCOVA]; Group II, F=6.241, P=0.003 [ANCOVA]). The only parameter to show a statistically significant variation over the study period was that of centre thickness for the lenses worn by the subjects in Group I (F=3.976, P=0.0063 [ANCOVA]), with a mean reduction in centre thickness of 0.022 mm at the 12 month visit.

No change was noted for either group or between groups for the other parameters measured. This study demonstrates that the parameters of rigid contact lenses manufactured from high Dk fluorocarbons are stable with only a non-clinically significant reduction in centre thickness for the contact lenses worn by the subjects in Group I.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Contact lenses can affect the cornea in a variety of ways. Corneal structure can be altered so that its thickness changes to involve the epithelium and the stroma. As a result, the curvature may be affected, but whether it is the front or the back surface that is affected depends on the type of lens used. If thickness increases sufficiently, corneal transparency may decrease. Contact lenses can also affect cellular structure of all layers of the cornea through mechanical trauma, hypoxia, or toxicity from solutions that are used in association with lenses. More serious complications, such as inflammation and infection, can arise. All these changes can be detected by clinicians using slitlamp biomicroscopes and keratometers if the changes are significant enough. Since the development of computers, optical instruments have become more sophisticated and have enabled the detection of subtle changes but have also facilitated more precise measurement of these conditions along with the ability to capture images of the alterations or defects. This article describes some of the newer techniques and, specifically, the application of optical coherence tomography, confocal microscopy, and esthesiometry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To describe the time-course and amplitude of changes to sub-foveal choroidal thickness (SFCT) induced by imposed hyperopic and myopic retinal defocus and to compare the responses in emmetropic and myopic subjects. METHODS: Twelve East Asian subjects (age: 18-34 years; six were emmetropic and six had myopia between -2.00 and -5.00 dioptres (D)) viewed a distant target (video movie at 6 m) for 60 min on two separate occasions while optical coherence tomography (OCT) images of the choroid were taken in both eyes every 5 min to monitor SFCT. On each occasion, one eye was optimally corrected for distance with a contact lens while the other eye wore a contact lens imposing either 2.00 D hyperopic or 2.00 D myopic retinal defocus. RESULTS: Baseline SFCT in myopic eyes (mean ± S.D.): 256 ± 42 μm was significantly less than in emmetropic eyes (423 ± 62 μm; p < 0.01) and was correlated with magnitude of myopia (-39 μm per dioptre of myopia, R(2) = 0.67: p < 0.01). Repeated measures anova (General Linear Model) analysis revealed that in both subject groups, 2.00 D of myopic defocus caused a rapid increase in SFCT in the defocussed eye (significant by 10 min, increasing to approximately 20 μm within 60 min: p < 0.01), with little change in the control eye. In contrast, 2.00 D of hyperopic defocus caused a decrease in SFCT in the experimental eye (significant by 20-35 min. SFCT decreased by approximately 20 μm within 60 min: p < 0.01) with little change in the control eye. CONCLUSIONS: Small but significant changes in SFCT (5-8%) were caused by retinal defocus. SFCT increased within 10 min of exposure to 2.00 D of monocular myopic defocus, but decreased more slowly in response to 2.00 D of monocular hyperopic defocus. In our relatively small sample we could detect no difference in the magnitude of changes to SFCT caused by defocus in myopic eyes compared to emmetropic eyes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The improvements in thickness accuracy of a steel strip produced by a tandem cold-roIling mill are of substantial interest to the steel industry. In this paper, we designed a direct model-reference adaptive control (MRAC)  scheme that exploits the natural level of excitation existing in the closed-loop with a dynamically constructed cascade-correlation neural network (CCNN) as a controller for cold roIling mill thickness control. Simulation results show that the combination of a such a direct MRAC scheme and the dynamically constructed CCNN significantly improves the thickness accuracy in the presence of disturbances and noise in comparison with to the conventional PID controllers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The surface resistance of polypyrrole (PPy)-coated polyester fabrics was investigated and related to coating thickness, which was controlled by adjusting the reactant concentrations. The thickness of the coating initially increased rapidly followed by a steady increase when the concentration of pyrrole (Py) was larger than a concentration of approximately 0.4 mg/ml. The surface resistance decreased from 106 to 103 Ω with increase in pyrrole concentration within 0.2 mg/ml until the concentration reached a value of about 0.4 mg/ml, above which the rate of decrease diminished. The effect of initial treatment with monomer or oxidant prior to polymerisation reaction with regards to thickness and surface resistance was minimal. The immersion time of the textile into the monomer solution prior to polymerisation reaction did not have a significant effect on the abrasion resistance.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Deployment of mobile technologies and applications in health care are becoming prevalent worldwide. As mobile innovation and standards in wireless continue to evolve, so does the mobile health care information systems framework. In this paper, we explore this evolving framework by synthesising current technologies, applications, issues and examining this through the actor-network theory (ANT) which seeks to understand socio-technical change by adopting a symmetric treatment of people and technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the rapid diffusion of innovative technologies in the healthcare industry, the potential of telemedicine has increasingly come into focus. Touted as a catalyst for an equitable healthcare framework among nations, research is wide and one spotlight is on the potential of this innovation to diffuse among the wider society. In this paper, we attempt a preliminary evaluation of the potential of telemedicine through the components of [Diffusion of Innovations (4th ed.). NY: The Free Press] diffusion of innovations theoretical lens, drawing also as relevant from reported literature. We expect that this preliminary evaluation will facilitate further academic research and make other stakeholders, such as regulators, medical practitioners, telecommunication providers and vendors, aware of potential steps to be taken to leverage telemedicine diffusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research findings become evidence when an individual decides that the information is relevant and useful to a particular circumstance. Prior to that point, they are unrelated facts. For research translation to occur, research evidence needs filtering, interpretation, and application by individuals to the specific situation. For this reason, decision science is complementary to knowledge translation science. Both aim to support the individual in deciding the most appropriate action in a dynamic environment where there are masses of uncensored and nonprioritized information readily available. Decision science employs research theories to study the cognitive processes underpinning the filtering and integration of current scientific information into changing contexts. Two meta-theories, coherence and correspondence theories, have been used to provide alternative views and prompt significant debate to advance the science. The aim of this article is to stimulate debate about the relationship between decision theory and knowledge translation. Discussed is the critical role of cognition in clinical decision making, with a focus on knowledge translation. A critical commentary of the knowledge utilization modeling papers is presented from a decision science perspective. The article concludes with a discussion on the implications for knowledge translation when viewed through the lens of decision science.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because outsourcing of information systems (IS) is now widespread, it is generally assumed to be successful. It is also often assumed that outsourcing risks are easily managed. In this paper we adopt an “evidence based management” approach to first test these assumptions through a qualitative metaanalysis of academic studies into IS outsourcing outcomes. Our research reveals a shortage of reliable and valid evidence for outsourcing’s benefits, and for the level of risk involved. We then use data from a series of focus groups to explain the paradox of widespread adoption of a strategy with limited empirical support. These focus groups were interpreted through the lens of research on a
range of cognitive mechanisms and biases that are known to affect decision makers. We conclude that cognitive mechanisms that are likely to affect sourcing decisions include framing biases, cognitive dissonance, attribution error, and the “optimism”, “confirmation”, “disconfirmation” and “overconfidence” biases. Given the shortage of supporting evidence, and the potential for these biases to operate, we argue that researchers need to be more critical in their analysis of reports of the success and risks of IS outsourcing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses a computer-aided methodology for thickness strain analysis (TSA) of sheet metal stampings using geometry and strain information that is extracted from finite element analysis (FEA) results. The system utilises both FEA results and an ultrasonic gauge capability expert system to assist press shop personnel, providing them with capabilities such as optimum measurement point location and an estimate of gauge error. Key advantages of this enhanced TSA methodology are related to overall efficiency and accuracy gains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interactive multimedia and the Internet challenge many aspects of teaching practice and assumptions. Catherine Beavis looks at a website that will support teachers and stimulate students.