25 resultados para lab session

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mobility service for hospital technicians involved in telemedicine applications is one of the key issues in providing more flexible and efficient in-house or remote health care services. Today, the Internet based communication has widened the opportunity of event monitoring systems in the medical field. The session initiation protocol (SIP) can work on a variety of devices and can be used to create a medical event notification system. Its adoption as the protocol of choice for third generation wireless networks allows for a robust and scalable environment. One of the advantages of SIP is that it supports personal mobility through the separation of user addressing and device addressing. In this paper, the authors propose a possible solution framework for telemedicine alert notification system based SIP-specific event notification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the design and simulation of a novel passive micromixer. The micromixer consists of two inlet tanks, one mixing channel and two outlet channels. In order to maximise the mixing efficiency, the following considerations are made: (i) The inlet tanks are followed by a series of microchannels, in which the flow is split. The microchannels are arranged in an interdigital manner to maximise the contact area between the two flows. (ii) The microchannels attached to the lower inlet tank have an upward slope while those attached to the upper tank have a downward slope. The higher-density flow is fed to the lower inlet tank and gets an upward velocity before entering the mixing channel. (iii) Two triangular barriers are placed within the mixing channel to impose chaotic advection and perturb the less-mixed flow along the top and bottom surfaces of the channel. (iv) Finally, two outlet channels are incorporated to discard the less-mixed flow. Three-dimensional simulations are carried out to evaluate the performance of the micromixer. Simulations are performed in the absence and presence of the gravitational force to analyse the influence of gravity on the micromixer. Mixing efficiencies of greater than 92% are achieved using water and a 1011'density biological solvent as the mixing fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integrated optical detection is considered to be an important operation in lab-on-a-chips. This paper presents an optical fiber-based micro-sensor that is capable of detecting food substance particles in a lab-on-a-chip. The system consists of a microcontroller and associated circuitry, a laser emitter, a laser receiver, fiber optic cables, a microfluidics chip, and the food substance samples to be tested. When the particles flow through the microfluidic channel in the chip, the receiver’s output voltage varies due to the particles blocking the passage of the laser ray. The changes in the collected signals are analyzed to count the number of particles. Experiments are conducted on several food substance samples including talcum powder, ground ginger, and soy sauce. The experimental results are presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper presents the design and simulation of a novel passive micromixer. The micromixer consists of two inlet tanks, one mixing channel and two outlet channels. In order to maximise the mixing efficiency, the following considerations are made : (i) The inlet tanks are followed by a series of microchannels, in which the flow is split. The microchannels are arranged in an interdigital manner to  maximise the contact area between the two flows. (ii) The microchannels attached to the lower inlet tank have an upward slope while those attached to the upper tank have a downward slope. The higher-density flow is fed to the lower inlet tank and gets an upward velocity before entering the mixing channel. (iii) Two triangular barriers are placed within the mixing channel to impose chaotic advection and perturb the less-mixed flow along the top and bottom surfaces of the channel. (iv) Finally, two outlet channels are incorporated to discard the less-mixed flow. Three-dimensional simulations are carried out to evaluate the performance of the micromixer. Simulations are performed in the absence and presence of the gravitational force to analyse the influence of gravity on the micromixer. Mixing efficiencies of greater than 92 % are achieved using water and a low-density biological solvent as the mixing fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a review of the recent trends and developments in non-optical biosensing platforms for lab-on- a-chip systems. This includes design considerations and applications of the non-optical biosensing platforms. The paper first categorizes the non-optical biosensors into four groups. The definition of each group together with a review of the reported works associated with the group are given. A performance analysis of different non-optical detection methods is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lab-on-a-chips are microfluidic devices which include biological laboratory functions on a single chip. They offer great advantages in terms of speed of analysis, precision, low sample and reagent consumption and automation of analysis. An efficient detection method in lab-on-a-chips is essential for the detection and quantification of chemical and biological parameters under examination. This review paper focuses on the recent research on optical detection techniques for LOC applications. Furthermore, several emerging detection paradigms which are still being matured are covered in this paper. Also, an analysis of the performance of different optical detection methods is given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Miniaturization is being increasingly applied to biological and chemical analysis processes. Lab-on-a-chip systems are direct creation of the advancement in the miniaturization of these processes. They offer a host of exciting applications in several areas including clinical diagnostics, food and environmental analysis, and drug discovery and delivery studies. This paper reviews lab-on-a-chip systems from their components perspective. It provides a categorization of the standard functional components found in lab-on-a-chip devices together with an overview of the latest trends and developments related to lab-on-a-chip technologies and their application in nanobiotechnology. The functional components include: injector, transporter, preparator, mixer, reactor, separator, detector, controller, and power supply. The components are represented by appropriate symbols allowing designers to present their lab-on-a-chip products in a standard manner. Definition and role of each functional component are included and complemented with examples of existing work. Through the approach presented in this paper, it is hoped that modularity and technology transfer in lab-on-a-chip systems can be further facilitated and their application in nanobiotechnology be expanded.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Agricultural discharge of herbicides to the Great Barrier Reef (GBR) poses significant threat to the marine ecosystem. This study evaluates the performance of a hybrid treatment system consists of a membrane bioreactor (MBR), UV disinfection unit and a granular activated carbon (GAC) column in treating ametryn which is one of the major herbicides in agricultural discharges. While the MBR alone removes only 40% of ametryn at a hydraulic retention time of 7.8 h, the hybrid system removed ametryn to below detection levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Regular resistance exercise completed for a number of weeks has been shown to increase insulin sensitivity and reduce the risk of diabetes-related complications. However, the acute responses to resistance exercise have not been adequately investigated in relation to training frequency.
AIM: To investigate the changes to insulin sensitivity in apparently healthy individuals following a single session of unaccustomed resistance exercise.
SUBJECTS AND METHODS: Ten sedentary, apparently healthy individuals performed a baseline oral glucose tolerance test and maximal strength testing. Participants then performed a single session of moderate-high intensity resistance exercise which was followed by 4 consecutive days of oral glucose tolerance testing, for which participants replicated their initial diet. Mean estimated insulin sensitivity change scores from baseline values and their 95% confidence intervals were compared to the previously determined values for a clinically meaningful change.
RESULTS: Two participants were identified as having hyperinsulinemia and their data were therefore removed from the main analysis. There was a clinically meaningful increase in insulin response (mean >7237 pmol·l⁻¹·120 min⁻¹) on all days following the exercise session and a clinically meaningful increase in glucose response (mean >81 mmol·l⁻¹·120 min⁻¹) on only the 3rd day following exercise. These changes suggest a potentially adverse short-term effect. Additionally, the 2 individuals with hyperinsulinemia displayed more extreme results.
CONCLUSION: These results suggest that insulin sensitivity may be impaired following a single session of unaccustomed resistance exercise for approximately 4 days in healthy untrained, older individuals. Further research is required for individuals with hyperinsulinemia