10 resultados para intima-media thickness

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atherosclerosis is a chronic inflammatory process that begins in early life. Improved identification of markers of early atherosclerosis via neonatal aortic intima-media thickness (aIMT) measurement may allow the development of interventions to prevent or reduce later cardiovascular disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Aortic intima-media thickness measured by transabdominal ultrasound (aIMT) is an intermediate phenotype of cardiovascular risk. We aimed to (1) investigate the reproducibility of aIMT in a population-derived cohort of infants; (2) establish the distribution of aIMT in early infancy; (3) compare measurement by edge-detection software to that by manual sonographic calipers; and (4) assess the effect of individual and environmental variables on image quality. Methods. Participants were term infants recruited to a population-derived birth cohort study. Transabdominal ultrasound was performed at six weeks of age by one of two trained operators. Thirty participants had ultrasounds performed by both operators on the same day. Data were collected on environmental (infant sleeping, presence of a sibling, use of sucrose, timing during study visit) and individual (post-conception age, weight, gender) variables. Two readers assessed image quality and measured aIMT by edge-detection software and a subset by manual sonographic calipers. Measurements were repeated by the same reader and between readers to obtain intra-observer and inter-observer reliability. Results: Aortic IMT was measured successfully using edge-detection in 814 infants, and 290 of these infants also had aIMT measured using manual sonographic calipers. The intra-reader intra-class correlation (ICC) (n = 20) was 0.90 (95% CI 0.76, 0.96), mean difference 1.5 μm (95% LOA -39, 59). The between reader ICC using edge-detection (n = 20) was 0.92 (95% CI 0.82, 0.97) mean difference 2 μm (95% LOA -45.0, 49.0) and with manual caliper measurement (n = 290) the ICC was 0.84 (95% CI 0.80, 0.87) mean difference 5 μm (95% LOA -51.8, 61.8). Edge-detection measurements were greater than those from manual sonographic calipers (mean aIMT 618 μm (50) versus mean aIMT 563 μm (49) respectively; p < 0.001, mean difference 44 μm, 95% LOA -54, 142). With the exception of infant crying (p = 0.001), no associations were observed between individual and environmental variables and image quality. Conclusion: In a population-derived cohort of term infants, aIMT measurement has a high level of intra and inter-reader reproducibility. Measurement of aIMT using edge-detection software gives higher inter-reader ICC than manual sonographic calipers. Image quality is not substantially affected by individual and environmental factors. © 2014 McCloskey et al.; licensee BioMed Central Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background.—Distinguishing pathological from physiological relationships between vessel size and aortic intima-media thickness (aIMT) is an important challenge, especially in growing children. We examined the relationship between childhood vessel diameter and aIMT and assessed common analytic approaches used to address this relationship.Methods.—We analyzed aIMT in two population-derived cohorts; 6-week-old infants and 19-year-olds. We simulated datasets in which we assumed a simple physiological relationship between vessel diameter and aIMT, and then superimposed possible pathological effects on aIMT; (a) intrauterine growth retardation, (b) macrosomia and (c) both intrauterine growth retardation and macrosomia. Using simulated datasets and cohorts, we evaluated analytic strategies including those in which the relationship between vessel diameter and aIMT was (a) ignored, (b) adjusted for by dividing aIMT by weight, or (c) adjusted for using varying regression techniques.Results.—aIMT was found to increase in proportion to vessel diameter in both cohorts (138 μm/mm at 6 weeks and 52 μm/mm at 19 years of age). Simply dividing aIMT by weight produced negative associations with weight across all datasets. By contrast, adjusting for vessel diameter as a covariate enabled accurate distinction of the direction of the association between aIMT and weight in all simulated datasets. These results were replicated in the cohort studies for both aIMT and carotid intima-media thickness.Conclusion.—There is a physiological relationship between vessel diameter and aIMT. Simply dividing aIMT by weight may lead to incorrect assumptions regarding the relationship between weight and aIMT. However, the physiological relationship is appropriately estimated by including vessel diameter as a covariate in regression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Infant body composition and postnatal weight gain have been implicated in the development of adult obesity and cardiovascular disease, but there are limited prospective data regarding the association between infant adiposity, postnatal growth and early cardiovascular parameters. Increased aortic intima-media thickness (aortic IMT) is an intermediate phenotype of early atherosclerosis. The aim of the present study was to investigate the relationship between weight and adiposity at birth, postnatal growth and aortic IMT. The Barwon Infant Study (n=1074 mother-infant pairs) is a population-derived birth cohort. Infant weight and other anthropometry were measured at birth and 6 weeks of age. Aortic IMT was measured by trans-abdominal ultrasound at 6 weeks of age (n=835). After adjustment for aortic size and other factors, markers of adiposity including increased birth weight (β=19.9 μm/kg, 95%CI 11.1, 28.6; P<0.001) and birth skinfold thickness (β=6.9 μm/mm, 95%CI 3.3, 10.5; P<0.001) were associated with aortic IMT at 6 weeks. The association between birth skinfold thickness and aortic IMT was independent of birth weight. In addition, greater postnatal weight gain was associated with increased aortic IMT, independent of birth weight and age at time of scan (β=11.3 μm/kg increase, 95%CI 2.2, 20.3; P=0.01). Increased infant weight and adiposity at birth, as well as increased early weight gain, were positively associated with aortic IMT. Excessive accumulation of adiposity during gestation and early infancy may have adverse effects on cardiovascular risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The incidence of gestational diabetes is increasing worldwide, exposing large numbers of infants to hyperglycaemia whilst in utero. This exposure may have a long-term negative impact on the cardiovascular health of the offspring. Novel methods to assess cardiovascular status in the neonatal period are now available—including measuring arterial intima-media thickness and retinal photography. These measures will allow researchers to assess the relative impact of intrauterine exposures, distinguishing these from genetic or postnatal environmental factors. Understanding the long-term impact of the intrauterine environment should allow the development of more effective health policy and interventions to decrease the future burden of cardiovascular disease. Initiating disease prevention aimed at the developing fetus during the antenatal period may optimise community health outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Methylmercury (MeHg) has been associated with increased risk for cardiovascular disease in some but not all epidemiology studies. These inconsistent results may stem from the fact that exposure typically occurs in the context of fish consumption, which is also associated with cardioprotective factors such as omega-3 fatty acids. Mechanistic information may help to understand whether MeHg represents a risk to cardiovascular health. MeHg is a pro-oxidant that inactivates protein sulfhydryls. These biochemical effects may diminish critical antioxidant defense mechanism(s) involved in protecting against atherosclerosis. One such defense mechanism is paraoxonase-1 (PON1), an enzyme present on high-density lipoproteins and that prevents the oxidation of blood lipids and their deposition in vascular endothelium. PON1 is potentially useful as a clinical biomarker of cardiovascular risk, as well as a critical enzyme in the detoxification of certain organophosphate oxons. MeHg and other metals are known to inhibit PON1 activity in vitro. MeHg is associated with lowered serum PON1 activity in a fish-eating population. The implications of lowering PON1 are evaluated by predicting the shift in PON1 population distribution induced by various doses of MeHg. An MeHg dose of 0.3 μg/kg/d is estimated to decrease the population average PON1 level by 6.1% and to increase population risk of acute cardiovascular events by 9.7%. This evaluation provides a plausible mechanism for MeHg-induced cardiovascular risk and suggests means to quantify the risk. This case study exemplifies the use of upstream disease biomarkers to evaluate the additive effect of chemical toxicity with background disease processes in assessing human risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Physical inactivity is a potent stimulus for vascular remodeling, leading to a marked decrease in conduit artery diameter. However, little is known about the impact of physical inactivity on artery wall thickness or wall:lumen ratio or the potential of exercise countermeasures to modify artery wall thickness. The purpose of the study was to examine the impact of 60 days of bed rest, with or without exercise countermeasures, on carotid and superficial femoral artery wall thickness. Eighteen men were assigned to bed rest (second Berlin Bed Rest Study) and randomly allocated to control, resistive exercise, or resistive vibration exercise. Both exercise countermeasures were applied 3 times per week while the subjects were in the supine position on the bed. Sonography was used to examine baseline diameter and wall thickness of the carotid and femoral arteries. Bed rest decreased diameter of the superficial femoral artery (P=0.001) but not the carotid artery (P=0.29). Bed rest induced a significant increase in carotid and superficial femoral artery wall thickness (P=0.007 and 0.03) and wall:lumen ratio (P=0.009 and 0.001). Exercise prevented the increase in wall thickness of the carotid artery. In addition, exercise partly prevented the increased wall:lumen ratio in the superficial femoral artery. In conclusion, 8 weeks of bed rest resulted in approximately 20% increase in conduit artery wall thickness. Exercise countermeasures completely (carotid artery) or partly (superficial femoral artery) abolished the increase in wall thickness. These findings suggest that conduit artery wall thickness, a vascular characteristic associated previously with atherosclerosis, can rapidly adapt to physical inactivity and exercise in humans.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Expansion of the extracellular matrix is a prominent but poorly characterized feature of tendinosis. The present study aimed to characterize the extent and distribution of the large aggregating proteoglycan versican in patients with patellar tendinosis. We obtained tendon from tendinopathy patients undergoing debridement of the patellar tendon and from controls undergoing intramedullary tibial nailing. Versican content was investigated by Western blotting and immunohistochemistry. Microvessel thickness and density were determined using computer-assisted image analysis. Markers for smooth muscle actin, endothelial cells (CD31) and proliferating cells (Ki67) were examined immunohistochemically. Western blot analysis and immunohistochemical staining revealed elevated versican content in the proximal patellar tendon of tendinosis patients (P=0.042). Versican content was enriched in regions of fibrocartilage metaplasia and fibroblast proliferation, as well as in the perivascular matrix of proliferating microvessels and within the media and intima of arterioles. Microvessel density was higher in tendinosis tissue compared with control tissue. Versican deposition is a prominent feature of patellar tendinosis. Because this molecule is not only a component of normal fibrocartilagenous matrices but also implicated in a variety of soft tissue pathologies, future studies should further detail both pathological and adaptive roles of versican in tendons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

 This paper presents the development of a two-dimensional model of multilayer bulk heterojunction organic nanoscale solar cells, consisting of the thickness of active layer and morphology of the device. The proposed model is utilized to optimize the device parameters in order to achieve the best performance using particle swarm optimization algorithm. The organic solar cells under research are from poly (3-hexylthiophene) and [6,6]-phenyl C61-butyric acid methyl ester type which are modelled to be investigated for performance enhancement. A three-dimensional fitness function is proposed involving domain size and active layer thickness as variables. The best results out of 20 runs of optimization show that the optimized value for domain size is 17 nm, while the short-circuit current vs. voltage characteristic shows a very good agreement with the experimental results obtained by previous researchers. © 2014 Springer Science+Business Media New York