4 resultados para insulated concrete panels

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The internal environment within an unconditioned wine barrel store, constructed from insulated concrete panels and located in south-eastern Australia, has been investigated during a summer and winter month. Average temperatures inside the store were found to be 13.7°C and 22.8°C in the winter and summer month respectively. A validated mathematical model of the store was used to investigate the contribution of the concrete walls, insulation and the wine itself to the internal thermal environment. The concrete walls were found to be the least influential.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Corrosion testing (half-cell and LPR) was carried out on a number reinforced concrete panels which had been taken from the fascia of a twenty five year old high rise building in Melbourne, Australia. Corrosion, predominantly as a result of carbonation of the concrete, was associated with a limited amount of cracking. A monitoring technique was established in which probe electrodes (reference and counter) were retro-fitted into the concrete. The probe electrode setup was identical for all panels tested. It was found that the corrosion behaviour of all panels tested closely fitted a family of results when the corrosion potential is plotted against the polarisation resistance (Rp). This enabled the development of a so-called 'control curve' relating the corrosion potential to the Rp for all of the panels under investigation. This relationship was also confirmed on laboratory samples, indicating that for a fixed geometry and experimental conditions a relationship between the potential and polarisation resistance of steel can be established for the steel-concrete system. Experimental results will be presented which indicate that for a given monitoring cell geometry, it may be possible to propose criteria for the point at which remediation measures should be considered. The establishment of such a control curve has enabled the development of a powerful monitoring tool for the assessment of a number of proposed corrosion remediation techniques. The actual effect of any corrosion remediation technique becomes clearly apparent via the type and magnitude of deviation of post remediation data from the original (preremediation) control curve.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper investigates the sound absorption characteristics of a precast panel system made from an environmentally sustainable concrete which can be used as an acoustical material. A current research project undertaken at the School of Architecture and Building, Deakin University, aims at utilising alternative materials and innovative approach to concrete precasting in the production of architecturally pleasing concrete panels. The normal incidence sound absorption coefficients of the assemblies were measured using an impedance tube. In general, the peak frequencies reduced with increasing thickness of concrete. The preliminary results indicate that the sound absorption of a three-layer variation of the panel meet design specifications related to acoustic performance. The major benefits of this investigated approach to concrete and concrete precasting are the ease of tunability to specific peak frequency, improved aesthetics and utilisation of industrial waste.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The use of green building materials and products promotes conservation of non-renewable resources and help reduce associated environmental impacts. This article reports the acoustical performance of a precast panel system made largely from concrete waste material. Two major applications for such panels that are being investigated currently include walls and claddings to industrial and commercial buildings and sound barriers for urban freeways. In this study, the application of the concrete panels for optimizing reverberation time (RT) in sports halls is tested using numerical simulations. As an innovative approach, additional layers are added to the precast panels to improve their appearance. The absorption coefficients of the concrete panel improved significantly with the architectural finish. The material can be tuned according to the required peak frequency. The architectural finish helped reduce the RT for frequencies above 500 Hz. Its application to different types of ceilings revealed that the RT of curved ceiling reduced up to 40% compared to flat and hybrid ceiling. A comparison of wall and ceiling modifications in small, medium and large sports halls showed that medium-sized halls have better acoustical performance compared with small and large halls with ceiling as well as wall treatment.