13 resultados para firefighter

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aching muscles and joints, lethargy, and sleepiness are all signs of firefighter fatigue during bushfire suppression. If not managed, fatigue may lead to injury or illness for the individual, which may also compromise the safety and productivity of their crew. Understanding the many sources of firefighter fatigue is, therefore, fundamental for all Australian fire agencies. This article will briefly address  several factors thought to contribute to firefighter fatigue including; sleep loss, firefighter’s work activity, their hydration, and nutrition, the hot and smoky  working environment, firefighter’s physical fitness and their experience. This brief overview draws on findings from firefighting research and the broader scientific literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fighting wildland fire is a physically demanding occupation. Wildland firefighters need to be physically fit to work safely and productively. To determine whether personnel are fit for duty, many firefighting agencies employ physical competency tests, such as the pack hike test (PHT). The PHT involves a 4.83-km hike over level terrain carrying a 20.4-kg pack within a 45-min period. The PHT was devised to test the job readiness of US wildland firefighters but is also currently used by some fire agencies in Australia and Canada. This review discusses the history and development of the PHT with emphasis on the process of test validation. Research-based training advice for the PHT is given, as well as discussion of the risks associated with completing the PHT. Different versions and modifications to the PHT have emerged in recent years and these are discussed with regard to their validity. Finally, this review addresses the relevance and validity of the PHT for Australian and Canadian wildland firefighters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monitoring an individual's thermic state in the workplace requires reliable feedback of their core temperature. However, core temperature measurement technology is expensive, invasive and often impractical in operational environments, warranting investigation of surrogate measures which could be used to predict core temperature. This study examines an alternative measure of an individual's thermic state, thermal sensation, which presents a more manageable and practical solution for Australian firefighters operating on the fireground. Across three environmental conditions (cold, warm, hot & humid), 49 Australian volunteer firefighters performed a 20-min fire suppression activity, immediately followed by 20min of active cooling using hand and forearm immersion techniques. Core temperature (Tc) and thermal sensation (TS) were measured across the rehabilitation period at five minute intervals. Despite the decline in Tc and TS throughout the rehabilitation period, there was little similarity in the magnitude or rate of decline between each measure in any of the ambient conditions. Moderate to strong correlations existed between Tc and TS in the cool (0.41, p<0.05) and hot & humid (0.57, p<0.05) conditions, however this was resultant in strong correlation during the earlier stages of rehabilitation (first five minutes), which were not evident in the latter stages. Linear regression revealed TS to be a poor predictor of Tc in all conditions (SEE=0.45-0.54°C) with a strong trend for TS to over-predict Tc (77-80% of the time). There is minimal evidence to suggest that ratings of thermal sensation, which represent a psychophysical assessment of an individual's thermal comfort, are an accurate reflection of the response of an individual's core temperature. Ratings of thermal sensation can be highly variable amongst individuals, likely moderated by local skin temperature. In account of these findings, fire managers require a more reliable source of information to guide decisions of heat stress management.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The world was captivated when footage of a badly burnt koala drinking water from a Victorian firefighter's bottle was uploaded to You Tube in February 2009. When the story of "Sam the Koala" was adopted by the mainstream media, recombinant themes were used to construct her story - from heroism and patriotism to villain vs victim and romance. While scholars have examined the changing role of the journalist in a converged world and the rise of "soft" news, this paper focuses on the way journalists create disjointed narratives around You Tube footage to extend a story s lifespan. We call these new narrative forms "fractured fairy tale news" to describe this emerging phenomenon of convergence culture. Further, we suggest that news media exploit the YouTube community for their own commercial gain and conclude that the fractured fairy tale style is a poor vehicle for the future of news.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study examined firefighters' ability to consume a prescribed fluid volume (1200 ml · h-1) during a wildland fire suppression shift and compare the effect of this additional fluid prescription with self-paced drinking on firefighters' hydration status and plasma sodium concentration post shift and their heart rate, core temperature and physical activity during their shift. Thirty-four firefighters were evenly divided into two drinking groups: self paced and prescribed. Prescribed drinkers did not meet the required 1200 ml·h-1 intake, yet they consumed twice the fluid drank by the self-paced group. No differences were noted between groups in plasma sodium levels or hydration status before or after their shift. Prescribed fluid consumption resulted in significantly lower core temperature between two and six hours into the shift. This did not coincide with lower cardiovascular strain, greater physical activity when compared to the self-paced drinking group. Additional fluid consumption (above self-paced intake) did not improve firefighter activity or physiological function (though it may buffer rising core temperature). It seems that wildland firefighters, at least in mild to warm weather conditions, can self-regulate their fluid consumption and work behaviour to leave the fireground hydrated at the conclusion of their shift.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Every year, Australian firefighters protect our nation from the devastation of bushfire. Understanding the impact of consecutive long shifts in hot, smoky conditions is essential for making decisions during campaign fires. At present, the evidence-base for such decisions is limited to laboratory studies with little relevance to bushfire suppression or field research where the impact of environmental and workload stressors cannot be measured. To counter these limitations, we have developed a three-day simulation that mimics the work and environment of campaign bushfire suppression. Construction of the simulation involved three stages; 1) data collection and analysis; 2) design and development; and 3) trial and refinement. The frequency, intensity, duration and type of physical work performed on the fireground is well documented and a modified applied cognitive task analysis, using experienced firefighters was used as a framework to describe in detail the non-physical aspects of the work. The design and development of the simulation incorporated the physical and non-physical aspects of the work into simulated tasks. Finally, experienced firefighters participated in trials of the simulation and reviewed digital recordings to ensure that the simulation accurately represented campaign bushfire suppression work. The outcome of this project is a valid, realistic, and reliable simulation of the physiological, physical and cognitive aspects of a volunteer firefighter on a three-day bushfire deployment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to examine 1) wildfire fighters' ability to consume the prescribed fluid volume (1200 mL h-1), 2) the effect of fluid intake on plasma sodium and hydration, and 3) the effect of fluid intake on firefighters' heart rate, core temperature and activity during emergency suppression shifts. Methods: Thirty-four firefighters were divided into ad libitum (AD, n = 17) and prescribed (PR, n = 17) drinking groups. Results: PR drinkers did not meet the prescribed fluid target, yet consumed over double the volume of AD drinkers. No differences between groups in plasma sodium or hydration were noted. PR drinking resulted in lower core temperature between 2 and 6 h. This did not coincide with reduced cardiovascular strain, greater work activity or larger distances covered when compared to AD drinkers. Conclusion: Extra fluid consumption (above AD) did not improve firefighter activity or physiological function (though PR firefighters core temperature was lower earlier in their shift). Firefighter can self-regulate their fluid consumption behavior and work rate to leave the fireground euhydrated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coronary heart disease (CHD) is a major problem for firefighters, even when considering the healthy worker effect (HWE). Although volunteer firefighters outnumber paid personnel, previous research has focused on paid US firefighters. By contrast, no CHD data for Australian firefighters exist. Risk factor data were collected from 2,943 Australian volunteer firefighters and CHD risk was compared with reference "low-risk" and Australian population data. Predicted CHD risk for male and female firefighter was 19.2% and 5.1%, respectively. Female firefighters high blood pressure and fasting glucose was significantly lower than the general population, whereas all other risk factors was similar to the general population. Firefighters' CHD risk was greater than other volunteer and paid emergency services, but the prevalence for most risk factors was similar to the general population. Therefore, Australian volunteer firefighters may not benefit from the HWE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To examine the effects of sleep restriction on firefighters' physical task performance during simulated wildfire suppression. METHODS: Thirty-five firefighters were matched and randomly allocated to either a control condition (8-hour sleep opportunity, n = 18) or a sleep restricted condition (4-hour sleep opportunity, n = 17). Performance on physical work tasks was evaluated across three days. In addition, heart rate, core temperature, and worker activity were measured continuously. Rate of perceived and exertion and effort sensation were evaluated during the physical work periods. RESULTS: There were no differences between the sleep-restricted and control groups in firefighters' task performance, heart rate, core temperature, or perceptual responses during self-paced simulated firefighting work tasks. However, the sleep-restricted group were less active during periods of non-physical work compared to the control group. CONCLUSIONS: Under self-paced work conditions, 4 h of sleep restriction did not adversely affect firefighters' performance on physical work tasks. However, the sleep-restricted group were less physically active throughout the simulation. This may indicate that sleep-restricted participants adapted their behaviour to conserve effort during rest periods, to subsequently ensure they were able to maintain performance during the firefighter work tasks. This work contributes new knowledge to inform fire agencies of firefighters' operational capabilities when their sleep is restricted during multi-day wildfire events. The work also highlights the need for further research to explore how sleep restriction affects physical performance during tasks of varying duration, intensity, and complexity.