25 resultados para electro-optic modulator

em Deakin Research Online - Australia


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electrochromic devices change their color and optical properties with applied voltage. A new symmetrical electrochromic configuration was constructed in previous works, where PEDOT acted as electrochromic layer or as counter electrode layer, depending on the polarity of the applied voltage. Devices of around 500mm2 and switching voltages from 0,5V to 2V are used in this work. Measured electrochemical impedance is fitted to an equivalent circuit based on a Randles cell, with Warburg impedance simulating ionic diffusion at low frequencies. Voltage dependence is analyzed for the first time in this kind of devices. Results show homogeneity problems in the contact layers, not seen in normal operation, and the voltage dependence on some construction parameters. This will be used to improve the devices construction, but improvements in the equivalent circuit should also be made. The proposed equivalent circuit is not valid after the redox reaction, from 1.5 to 2V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We measured thresholds for detecting changes in colour and in luminance contrast in observers with multiple sclerosis (MS) and/or optic neuritis (ON) to determine whether reduced sensitivity occurs principally in red-green or blue-yellow second-stage chromatic channels or in an achromatic channel. Colour thresholds for the observers with MS/ON were higher in the red-green direction than in the blue-yellow direction, indicating greater levels of red-green loss than blue-yellow loss. Achromatic thresholds were raised less than either red-green or blue-yellow thresholds, showing less luminance-contrast loss than chromatic loss. With the MS/ON observers, blue-yellow and red-green thresholds were positively correlated but increasing impairment was associated with more rapid changes in red-green thresholds than blue-yellow thresholds. These findings indicate that demyelinating disease selectively reduces sensitivity to colour vision over luminance vision and red-green colours over blue-yellow colours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Colour and luminance-contrast thresholds were measured in the presence of dynamic Random Luminance-contrast Masking (RLM) in individuals who had had past diagnoses of optic neuritis (ON) some of whom have progressed to a diagnosis of multiple sclerosis (MS). To explore the spatio-temporal selectivity of chromatic and luminance losses in MS/ON, thresholds were measured using three different sizes and modulation rates of the RLM displays: small checks modulating slowly, medium-sized checks with moderate modulation and large checks modulating rapidly. The colour of the chromatic stimuli used were specified in a cone-excitation space to measure relative impairments in red–green and blue–yellow chromatic channels. These observers showed chromatic thresholds along the L/(L + M) axis that were higher than those along the S-cone axis for all display sizes/modulation rates and both red-green and blue-yellow colour thresholds were higher than luminance-contrast thresholds. The principal change in thresholds with spatio-temporal changes in the display was a reduction in thresholds for L/(L + M) and S-cones with increasing check size and modulation rate. However, luminance contrast thresholds did not change with display size/rate. These results are consistent with MS/ON selectively affecting processing in colour pathways rather than in the magnocellular pathway, and that within the colour pathways neurones with opposed L- and M-cone inputs are more damaged than colour-opponent neurons with input from S-cones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many herbal medicines are widely used as immuno-modulators in Asian countries. Ganoderma lucidum (Lingzhi) is one of the most commonly used herbs in Asia and preclinical studies have established that the polysaccharide fractions of G. lucidum have potent immuno-modulating effects. However, clinical evidence for this is scanty. The present open-labeled study aimed to evaluate the effects of G. lucidum polysaccharides on selected immune functions in patients with advanced colorectal cancer. Forty-seven patients were enrolled and treated with oral G. lucidum at 5.4 g/day for 12 weeks. Selected immune parameters were monitored using various immunological methods throughout the study. In 41 assessable cancer patients, treatment with G. lucidum tended to increase mitogenic reactivity to phytohemagglutinin, counts of CD3, CD4, CD8 and CD56 lymphocytes, plasma concentrations of interleukin (IL)-2, IL-6 and interferon (IFN)-γ, and NK activity, whereas plasma concentrations of IL-1 and tumor necrosis factor (TNF)-α were decreased. For all of these parameters, no statistical significance was observed when a comparison was conducted between baseline and those values after a 12-week treatment with G. lucidum. The changes of IL-1 were correlated with those for IL-6, IFN-γ, CD3, CD4, CD8 and NK activity (p < 0.05) and IL-2 changes were correlated with those for IL-6, CD8 and NK activity. The results indicate that G. lucidum may have potential immuno-modulating effect in patients with advanced colorectal cancer. Further studies are needed to explore the benefits and safety of G. lucidum in cancer patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many modulation systems in comprehensive 2D GC (GC×GC) are based on cryogenic methods. High trapping temperatures in these systems can result in ineffective trapping of the more volatile compounds, whilst temperatures that are too low can prevent efficient remobilisation of some compounds. To better understand the trapping and release of compounds over a wide range of volatilities, we have investigated a number of different constant temperature modulator settings, and have also examined a constant temperature differential between the cryo-trap and the chromatographic oven. These investigations have led us to modify the temperature regulation capabilities of the longitudinally modulated cryogenic system (LMCS). In contrast to the current system, where the user sets a constant temperature for the cooling chamber, the user now sets the temperature difference between the cryo-trap and the chromatographic oven. In this configuration, the cooling chamber temperature increases during the chromatographic run, tracking the oven temperature ramp. This produces more efficient, volatility-dependent modulation, and increases the range of volatile compounds that can be analysed under optimal trap-and-release conditions within a single analytical run. This system also reduces cryogenic fluid consumption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the direct electro-chemical reduction of graphene oxide to graphene from aqueous suspension by applying reduction voltages exceeding -1.0 to -1.2 V. The conductivity of the deposition medium is of crucial importance and only values between 4-25 mS cm-1 result in deposition. Above 25 mS cm-1 the suspension de-stabilises while conductivities below 4 mS cm-1 do not show a measurable deposition rate. Furthermore, we show that deposition can be carried out over a wide pH region ranging from 1.5 to 12.5. The electro-deposition process is characterised in terms of electro-chemical methods including cyclic voltammetry, quartz crystal microbalance, impedance spectroscopy, constant amperometry and potentiometric titrations, while the deposits are analysed via Raman spectroscopy, infra-red spectroscopy, X-ray photoelectron spectroscopy and X-ray diffractometry. The determined oxygen contents are similar to those of chemically reduced graphene oxide, and the conductivity of the deposits was found to be ~20 S cm -1.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. The authors compared the visual gaze behaviors of glaucoma subspecialists with those of ophthalmology trainees during optic disc and retinal nerve fiber layer (RNFL) examination.

Methods. Seven glaucoma subspecialists and 23 ophthalmology trainees participated in the project. Participants were shown eight glaucomatous optic disc images with varied morphology. Eye movements during examination of the optic disc photographs were tracked. For each disc image, graders were asked to assign a presumptive diagnosis for probability of glaucoma. There was no time restriction.

Results. Overall, trainees spent more time looking at disc images than glaucoma subspecialists (21.3 [13.9–37.7] vs. 16.6 [12.7–19.7]) seconds; median [interquartile range (IQR)], respectively; P < 0.01) and had no systematic patterns of gaze behavior, and gaze behavior was unaltered by disc morphology or topographic cues of pathology. Experienced viewers demonstrated more systematic and ordered gaze behavior patterns and spent longer times observing areas with the greatest likelihood of pathology (superior and inferior poles of the optic nerve head and adjacent RNFL) compared with the trainees. For discs with focal pathology, the proportion of total time spent examining definite areas of pathology was 28.9% (22.4%–33.6%) for glaucoma subspecialists and 13.5% (12.2%–19.2%) for trainees (median [IQR]; P < 0.05). Furthermore, experts adapted their viewing habits according to disc morphology.

Conclusions. Glaucoma subspecialists adopt systematic gaze behavior when examining the optic nerve and RNFL, whereas trainees do not. It remains to be elucidated whether incorporating systematic viewing behavior of the optic disc and RNFL into teaching programs for trainees may expedite their acquisition of accurate and efficient glaucoma diagnosis skills.