44 resultados para column

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semi-automated flow injection instrumentation, incorporating a small anion exchange column coupled with tris(2,2′-bipyridyl)ruthenium(II) (Ru(bipy)32+) chemiluminescence detection, was configured and utilised to develop rapid methodology for the determination of sodium oxalate in Bayer liquors. The elimination of both negative and positive interferences from aluminium(III) and, as yet, unknown concomitant organic species, respectively are discussed. The robustness of the methodology was considerably enhanced by using the temporally stable form of the chemiluminescence reagent, tris(2,2′-bipyridyl)ruthenium(III) perchlorate in dry acetonitrile. Real Bayer process samples were analysed and the results obtained compared well with those performed using standard methods within industrial laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oxidation of selected clinically important neurotransmitter metabolites with acidic potassium permanganate in the presence of polyphosphates evokes chemiluminescence of sufficient intensity to enable the sensitive determination of these species. Limits of detection for 5-hydroxyindole-3-acetic acid (5-HIAA), vanilmandelic acid (VMA; α,4-dihydroxy-3-methoxybenzeneacetic acid), 4-hydroxy-3-methoxyphenylglycol (MHPG), homovanillic acid (HVA, 4-hydroxy-3-methoxyphenylacetic acid) and 3,4-dihydroxyphenylacetic acid (DOPAC) were between 5 × 10−9 and 4 × 10−8 M, using flow-injection analysis methodology. In addition, we demonstrate the rapid determination of homovanillic acid and 5-hydroxyindole-3-acetic acid in human urine – without the need for extraction procedures – using monolithic column chromatography with chemiluminescence detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We address the blind equalization of finite-impulse-response (FIR), multiple-input multiple-output (MIMO) channels excited by constant modulus (CM) signals. It is known that the algorithms based on the constant modulus (CM) criterion can equalize an FIR MIMO channel that is irreducible and column-reduced. We show in this paper that the CM property of signals can be exploited to construct a zero-forcing equalizer for a non-irreducible and non-column-reduced channel. We also give a lower bound for the order of the equalizer. Simulation examples demonstrate the proposed result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have combined high-performance liquid chromatography (HPLC) separations using a monolithic column with acidic potassium permanganate and tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection in a rapid and highly sensitive method to monitor the process of extracting opiate alkaloids from Papaver somniferum. Due to the high flow rates allowed with the monolithic column and the inherent selectivity of the chemiluminescence reactions, the four predominant alkaloids – morphine, codeine, oripavine and thebaine – were determined in less than 2 min. The results obtained with numerous process samples compared favourable with those of the standard HPLC methodology. Limits of detection were 1 × 10−10 M, 5 × 10−10 M, 5 × 10−10 M and 1 × 10−9 M, for morphine, codeine, oripavine and thebaine, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have combined the generation of solvent gradients using milliGAT pumps, chromatographic separations with monolithic columns and chemiluminescence detection in an instrument manifold that approaches the automation and separation efficiency of HPLC, whilst maintaining the positive attributes of flow injection analysis (FIA), such as manifold versatility, speed of analysis and portability. As preliminary demonstrations of this hybrid FIA/HPLC system, we have determined six opiate alkaloids (morphine, pseudomorphine, codeine, oripavine, ethylmorphine and thebaine) and four biogenic amines (vanilmandelic acid, serotonin, 5-hydroxyindole-3-acetic acid and homovanillic acid) in human urine, using tris(2,2′-bipyridyl)ruthenium(III) and acidic potassium permanganate chemiluminescence detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-performance liquid chromatography (HPLC) with tris(2,2-bipyridyl)ruthenium(II) chemiluminescence detection methodology is reported for the determination of the atypical antipsychotic drug quetiapine and the observation of its major active and inactive metabolites in human urine and serum. The method uses a monolithic chromatographic column allowing high flow rates of 3mL min−1 enabling rapid quantification. Flow injection analysis (FIA) with tris(2,2-bipyridyl)ruthenium(II) chemiluminescence detection and HPLC time of flight mass spectrometry (TOF-MS) were used for the determination of quetiapine in a pharmaceutical preparation to establish its suitability as a calibration standard. The limit of detection achieved with FIA was 2×10−11 mol L−1 in simple aqueous solution. The limits of detection achieved with HPLC were 7×10−8 and 2×10−10 mol L−1 in urine and serum, respectively. The calibration range for FIA was between 5×10−9 and 1×10−6 mol L−1. The calibration ranges for HPLC were between 1×10−7–1×10−4 and 1×10−8–1×10−4 mol L−1 in urine and serum, respectively. The quetiapine concentrations in patient samples were found to be 3×10−6 mol L−1 in urine and 7×10−7 mol L−1 in serum. Without the need for preconcentration, the HPLC detection limits compared favourably with those in previously published methodologies. The metabolites were identified using HPLC-TOF-MS.