31 resultados para building simulation

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermal and visual comfort play a very important role regarding the satisfaction of occupants with their working environments. The most effective method to achieve thermal comfort in offices is to reduce cooling loads in order to avoid additional energy-consuming devices for cooling. Building simulation software can be a helpful tool for optimisation, and typically standard values for the influencing parameters are used in order to ensure compliance to norms and regulations.

In practice many of those parameters turn out to be different compared to the simulation assumptions and the reasons may be the chosen room or building related properties as well as the user behaviour influenced by the task and the corporate culture of the company.

This paper investigates exemplary for the climate of Hamburg, Germany and a naturally ventilated typical office room, the optimisation potential of the building- and user-related parameters for thermal comfort, daylighting and view when using realistic input data for building simulation. The study has been conducted with the EnergyPlus based simulation software “Primero-Komfort” [1].

Relevância:

70.00% 70.00%

Publicador:

Resumo:

According to the Intergovernmental Panel on Climate Change the buildings sector has the largest mitigation potential for CO2 emissions. Especially in office buildings, where internal heat loads and a relatively high occupant density occur at the same time with solar heat gains, overheating has become a common problem. In Europe the adaptive thermal comfort model according to EN 15251 provides a method to evaluate thermal comfort in naturally ventilated buildings. However, especially in the context of the climate change and the occurrence of heat waves within the last decade, the question arises, how thermal comfort can be maintained without additional cooling, especially in warm climates. In this paper a parametric study for a typical cellular naturally ventilated office room has been conducted, using the building simulation software EnergyPlus. It is based on the Mediterranean climate of Athens, Greece. Adaptive thermal comfort is evaluated according to EN 15251. Variations refer to different building design priorities, and they consider the variability of occupant behaviour and internal heat loads by using an ideal and worst case scenario. The influence of heat waves is considered by comparing measured temperatures for an average and an exceptionally hot year within the last decade. Since the use of building controls for shading affects thermal as well as visual comfort, daylighting and view are evaluated as well. Conclusions are drawn regarding the influence and interaction of building design, occupants and heat waves on comfort and greenhouse gas emissions in naturally ventilated offices, and related optimisation potential.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Building simulation is most useful and most difficult in early design stages. Most useful since the optimisation potential is large and most difficult because input data are often not available at the level of resolution required for simulation software. The aim of this paper is to addresses this difficulty, by analysing the predominantly qualitative information in early stages of an architectural design process in search for indicators towards quantitative simulation input. The discussion in this paper is focused on cellular offices. Parameters related to occupancy, the use of office equipment, night ventilation, the use of lights and blinds are reviewed based on simulation input requirements, architectural considerations in early design stages and occupant behaviour considerations in operational stages. A worst and ideal case scenario is suggested as a generic approach to model occupant behaviour in early design stages when more detailed information is not available. Without actually predicting specific occupant behaviour, this approach highlights the magnitude of impact that occupants can have on comfort and building energy performance and it matches the level of resolution of available architectural information in early design stages. This can be sufficient for building designers to compare the magnitude of impact of occupants with other parameters in order to inform design decisions. Potential indicators in early design stages towards the ideal or worst case scenario are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

According to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change (IPCC), the construction sector has the greatest potential for climate change mitigation. This work investigates the potential for climate change mitigation in naturally ventilated and mixed mode office buildings, by evaluating the range of influence of building design and occupants on greenhouse gas emissions as well as thermal and visual comfort.

Thermal comfort is evaluated according to the EN 15251 adaptive thermal comfort model, visual comfort is based on daylight autonomy and view. Parametric studies have been conducted based on building simulation for the climate of Athens, Greece. Input data are based on a literature review, and on results from a field study conducted among office occupants and architects in Athens.

The results show that the influence of occupants on greenhouse gas emissions is larger than the influence of building design. Energy saving office equipment, as well as active use of building controls for shading and lighting by occupants are crucial parameters regarding the reduction of CO2 emissions. In mixed mode buildings, the coefficient of performance of the cooling system is an important parameter as well. Regarding thermal and visual comfort, the influence of building design is predominant. A green building, well protected against heat from the sun and able to balance solar and internal heat gains, provides higher comfort levels and is less affected by the influence of occupants. In mixed mode buildings, building design is the predominant influence on the magnitude of cooling loads. A hot summer including heat waves can significantly reduce thermal comfort and increase the resulting greenhouse gas emissions. Green buildings are least affected by these influences.

The EN 15251 adaptive thermal comfort model provides a thermal comfort evaluation method valid throughout Europe. However, for the Mediterranean climate of Athens, Greece, most of the configurations investigated within this study do not meet the requirements according to this model. EN 15251 refers to an adaptive thermal comfort model for naturally ventilated and to a static model for mechanically ventilated buildings. For mixed mode buildings, the static model is recommended, but literature indicates that occupants in those buildings might be more tolerant towards higher temperatures. The hypothetical application of the EN 15251 adaptive thermal comfort model in mixed mode offices, as investigated in this study, shows potential for greenhouse gas emission savings. However, this influence is small compared to that of building design and occupants. Conclusions are drawn regarding the categorisation and exceeding criteria according to EN 15251 adaptive thermal comfort model for offices in a Mediterranean climate.

The results of this work show, that not only green buildings, but also green occupants can significantly contribute to the mitigation of the climate change. Mechanisms of the real estate market as well as the lifestyle of occupants are important influences in this context. Sustainability therefore refers to finding the right balance between occupant’s comfort expectations and resulting greenhouse gas emissions for a specific building, rather than optimisation of single parameters

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes a holistic approach to comfort and greenhouse gas emissions in mixed mode offices. It is based on parametric studies for a typical cellular office in the Mediterranean climate of Athens, Greece, using building simulation.

Considered parameters are the influence of different building design, varying occupant behaviour and internal heat loads, as well as of an exceptionally hot summer. Additionally, the performance of a cooling strategy following the comfort limits according to the EN 15251 adaptive model is compared with the common fixed cooling set point 22°C.

The performance of mixed mode offices is evaluated regarding thermal comfort, daylight autonomy and related greenhouse gas emissions. Results indicate strategies to improve sustainability in mixed mode offices in Athens, by balancing the influencing parameters.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

According to IPCC (Intergovernmental Panel on Climate Change), the largest use of energy in commercial buildings is space heating in colder climates and air conditioning in hot climates. In Europe, the Directive on the energy performance of buildings EPBD (European Energy Performance of Buildings Directive) [1] provides a framework for national building performance regulations and calculation procedures. However, there are often large discrepancies between calculated and measured energy performance of buildings. One main reason is the behaviour of occupants, which is often not reflected in calculation models.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Strong heat waves in the past decade and resulting legal cases which gave full responsibility for indoor thermal comfort to building professionals lead to an increased uncertainty how to maintain thermal comfort in offices without the use of a cooling system. Adaptive thermal comfort standards such as EN 15251 and Ashrae Standard 55 provide methodologies to evaluate comfort in naturally ventilated spaces. Based on a parametric study for a typical cellular office in the context of Athens, Greece, and using the building simulation software EnergyPlus, this study investigates the potentials for the applicability of natural ventilation in a Mediterranean climate. The Ashrae Standard 55 and EN 15251 adaptive thermal comfort models are compared in this context, and conclusions are drawn how the use of natural ventilation based on adaptive models can be further encourgaged.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper investigates the impact of climate change on comfort and energy performance in offices in relation to the influence of building design and occupants. It focuses on a typical cellular office room in the context of Athens, Greece, as input for a parametric study using the building simulation software EnergyPlus. Three different building design variations are combined with two different occupant scenarios and 4 different weather data sets for IPCC climate change scenario A2.

For naturally ventilated buildings adaptive thermal comfort is evaluated according to ASHRAE Standard 55 and EN 15251. For mixed mode context evaluation is focused on greenhouse gas emissions and peak heating / cooling loads. Results indicate significant impact of the climate change on thermal comfort, and deviations between both comfort models. Comparing climate change, building design and occupant scenarios indicates that building design is the predominant influence on thermal comfort, whereas occupants are the predominant influence on greenhouse gas emissions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A key criterion by which any building will be judged when its environmental impact is assessed is its thermal performance. This paper describes the simulation of an office module in a three-storey university building in south eastern Australia. The module, located at the north-west corner of the top floor of the building, was chosen because it is likely to have the highest cooling load - a primary concern of energy conscious designers of commercial buildings for most parts of Australia.

In the paper, the initial key assumptions are stated, together with a description of a "reference" or base case, against which improvements in thermal performance were measured. The simulation process identified the major influences on thermal performance. This enabled changes in materials and construction, as well as basic design concepts to be evaluated. Features incorporated into the base case such as a metal roof and glazed walkway were found to have adverse influence on energy consumption, and were consequently rejected in preference for an improved design which included a hypocaust slab system on the roof of the office module. The final design was predicted to reduce the annual energy consumption for heating and cooling by 72% and 76% respectively.

La performance thermique est l'un des critegraveres cleacutes de l'eacutevaluation environnementale de tout bacirctiment. Cet article deacutecrit la simulation d'un module de bureau appartenant agrave un immeuble de trois eacutetages d'une universiteacute du sud-est de l'Australie. Ce module, situeacute agrave l'angle nord-ouest de l'eacutetage supeacuterieur du bacirctiment a eacuteteacute choisi car c'eacutetait lui qui, vraisemblablement, avait la charge de refroidissement la plus eacuteleveacutee, ce qui est une preacuteoccupation majeure des concepteurs conscients des problegravemes d'eacutenergie des bacirctiments commerciaux dans la plus grande partie du pays. Le processus de simulation a fait apparaicirctre trois influences principales sur la performance thermique par rapport agrave un cas de base. Cela a permis d'eacutevaluer les modifications apporteacutees aux mateacuteriaux et agrave la construction ainsi qu'aux avant-projets. Les caracteacuteristiques inteacutegreacutees dans le cas de base comme le toit meacutetallique et la passerelle vitreacutee avaient une influence neacutefaste sur la consommation d'eacutenergie et ont donc eacuteteacute rejeteacutees au beacuteneacutefice d'un concept ameacutelioreacute qui comprenait une dalle de type hypocauste sur le toit du module de bureau. Le concept final devrait reacuteduire la consommation annuelle d'eacutenergie pour le chauffage et le refroidissement de 72 % et 76 % respectivement, ce qui donne une ideacutee de la valeur ajouteacutee au processus de production agrave partir de proceacutedures avanceacutees de modeacutelisation et de simulation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Traditional!y, the simulation of buildings has focused 011 operational energy consumption in an attempt to determine the potential for energy savings. Whilst operational energy of Australian buildings accounts for around 20% of total energy consumption nationally, embodied energy represents 20 to 50 times the annual operational energy of 1110st Australian buildings. Lower values have been shown through a number of studies that have analysed the embodied energy of buildings and their products, however these have now shown to be incomplete in system boundary. Many of these studies have used traditional embodied energy analysis methods, such as process analysis and input-output analysis, Hybrid embodied energy analysis methods have been developed, but these need to be compared and validated. This paper reports on preliminary work on this topic. The findings so far suggest that current best-practice methods are sufficiently accurate for most typical applications, but this is heavily dependant upon data quality and availability.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The recently erected concept of building deconstruction has significantly promoted building components and materials reuse and recycling where building is carefully dismantled into reusable parts. Current research and practices of building deconstruction mainly focus on issues of process before and during the deconstruction such as hazardous material detection, deconstruction design and deconstruction technology. The issues after the deconstruction project are rarely considered. Waste reuse and recycling are enabled through deconstruction yet not practically achieved, and especially the demands of waste building components and materials are hard to appear and match the actual waste production in a building deconstruction project. To deal with this awkward situation, the waste production needs to be conducted in a demand-oriented way. It needs to be thoughtfully planned and scheduled prior to the physical deconstruction as an essential portion of deconstruction project planning and scheduling. Furthermore, the relationship between waste production and structural characteristics of the building creates a serious consideration affecting a deconstruction plan. As a result, a waste production simulation will facilitate waste reuse and recycling in a deconstruction project. It serves as a crucial section of deconstruction planning and design. This research aims to describe the concept of waste production simulation and investigate various management and technical aspects of waste production simulation for building deconstruction projects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A commercial roller-skating centre in southern Australia had condensation problems on both the roof and floor. The building is a typical warehouse-type structure with a high level of natural ventilation due to poor construction and permanently open vents. A computer model of the building, using the thermal simulation software TRNSYS, was calibrated from a sensitivity analysis of three key parameters, namely air exchange rate, roof surface heat transfer coefficient and deep ground temperature. The predicted times of condensation on the roof were compared with site observations. The time of year was predicted with acceptable accuracy, although earlier in the morning than had been observed. The effect of installing foil insulation in the roof was simulated. Under normal winter conditions, this modification was enough to stop the condensation. However, in unusually cold and humid conditions, condensation still occurred on both surfaces. This was overcome by heating the floor (15 W/m 2 ) for approximately eight hours. Subsequent modifications have demonstrated the value of the simulations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 2100 m2 (GFA) two-storey rammed earth building was built on the Thurgoona campus of Charles Sturt University in 1999. The building is novel both in the use of materials and equipment for heating and cooling. The climate at Wodonga can be characterised as hot and dry, so the challenge of providing comfortable working conditions with minimal energy consumption is considerable. This paper describes a thermal model of one of the second-storey offices on the west-end of the building. The simulation software, TRNSYS, has been used to predict office temperatures and comparisons are made between these and measurements made over a typical week in summer. Reasonable agreement has been achieved under most conditions. The model has been used to investigate key building parameters and strategies, including night flushing, to improve the thermal comfort in the office.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In 1999, a 2100 m2 (GFA) two-storey rammed earth building was built on the Thurgoona campus of Charles Sturt University. The climate at Thurgoona is considered Mediterranean – hot dry summers and cool winters. The internal and external walls of the building are constructed from 300-mm thick rammed earth (pise) and are load bearing. The thermal performance of the building has been investigated, both experimentally and theoretically over the summer and winter seasons of 2000/1. As part of these investigations heat flux sensors and thermistors were embedded in one of the external walls of a ground floor office, and data from the transducers has been used to determine the heat flow at the internal and external wall surfaces. The simulation software, TRNSYS, has been used to model the thermal performance of the same office. The programme allows the user to calculate the heat flow at the walls, which define any particular thermal zone. A comparison of measured and predicted values of heat flows and air temperatures has been used to validate the model. The model has then been used to simulate the effect of shading and added insulation on the thermal performance of the external walls in both summer and winter and these results are also presented in this paper.