17 resultados para anodization

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanotube structures have attracted tremendous attention in recent years in many applications. Among such nanotube structures, titania nanotubes (TiO2) have received paramount attention in the medical domain due to their unique properties, represented by high corrosion resistance, good mechanical properties, high specific surface area, as well as great cell proliferation, adhesion and mineralization. Although lot of research has been reported in developing optimized titanium nanotube structures for different medical applications, however there is a lack of unified literature source that could provide information about the key parameters and experimental conditions required to develop such optimized structure. This paper addresses this gap, by focussing on the fabrication of TiO2 nanotubes through anodization process on both pure titanium and titanium alloys substrates to exploit the biocompatibility and electrical conductivity aspects, critical factors for many medical applications from implants to in-vivo and in-vitro living cell studies. It is shown that the morphology of TiO2 directly impacts the biocompatibility aspects of the titanium in terms of cell proliferation, adhesion and mineralization. Similarly, TiO2 nanotube wall thickness of 30-40nm has shown to exhibit improved electrical behaviour, a critical factor in brain mapping and behaviour investigations if such nanotubes are employed as micro-nano-electrodes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Interfacial chemistry and adhesion between titanium dioxide (TiO2) nanotube layers and titanium (Ti) substrates were studied in this Article. TiO2 nanotube layers were produced on pure Ti by anodization and annealed in air for different time durations. The adhesion of the TiO2 nanotube layers was then investigated by Rockwell C indentation test. Results show that adhesion of TiO2 nanotube layers improved with the extension of annealing time. This improvement in adhesion of TiO2 nanotube layers was analyzed from the viewpoint of interfacial chemistry using energy dispersive X-ray spectrometry (EDS) and X-ray photoelectron spectroscopy (XPS). It suggests that more Ti-O bonds formed in the interface after annealing, and this led to the improved adhesion of the TiO2 nanoube layers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Titania nanotube films were produced by anodization of titanium foil. The titania nanotube films were annealed at different temperatures. Morphology evolution, phase transformation and electrical conductivity of the titania nanotubes were studied. Results showed that the nanotube walls became rough, porous and even collapsed after annealed at 400, 500 and 600°C respectively. Titania anatase phase formed after annealed at 400°C; the amount of anatase phase increased as the annealing temperature increased. The conductivity of the nanotube film annealed at 400°C was improved greatly compared with the conductivity of the as-anodized nanotube film. However, the conductivity of the nanotube films annealed at higher temperatures decreased. The effect of the morphology on the electronic conductivity of the titania nanotube films was discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Anodization of titanium and its alloys, under controlled conditions, generates a nanotubular architecture on the material surface. The biological consequences of such changes are poorly understood, and therefore, we have analyzed the cellular and molecular responses of osteoblasts that were plated on nanotubular anodized surface of a titanium-zirconium (TiZr) alloy. Upon comparing these results with those obtained on acid etched and polished surfaces of the same alloy, we observed a significant increase in adhesion and proliferation of cells on anodized surfaces as compared to acid etched or polished surface. The expression of genes related to cell adhesion was high only on anodized TiZr, but that of genes related to osteoblast differentiation and osteocalcin protein and extracellular matrix secretion were higher on both anodized and acid etched surfaces. Examination of surface morphology, topography, roughness, surface area and wettability using scanning electron microscopy, atomic force microscopy, and contact angle goniometry, showed that higher surface area, hydrophilicity, and nanoscale roughness of nanotubular TiZr surfaces, which were generated specifically by the anodization process, could strongly enhance the adhesion and proliferation of osteoblasts. We propose that biological properties of known bioactive titanium alloys can be further enhanced by generating nanotubular surfaces using anodization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, the fabrication and growth mechanism of net-shaped micropatterned self-organized thin-film TiO2 nanotube (TFTN) arrays on a silicon substrate are reported. Electrochemical anodization is used to grow the nanotubes from thin-film titanium sputtered on a silicon substrate with an average diameter of ?30 nm and a length of ?1.5 ?m using aqueous and organic-based types of electrolytes. The fabrication and growth mechanism of TFTN arrays from micropatterned three-dimensional isolated islands of sputtered titanium on a silicon substrate is demonstrated for the first time using focused-ion-beam (FIB) technique. This work demonstrates the use of the FIB technique as a simple, high-resolution, and maskless method for high-aspect-ratio etching for the creation of isolated islands and shows great promise toward the use of the proposed approach for the development of metal oxide nanostructured devices and their integration with micro- and nanosystems within silicon-based integrated-circuit devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to assess a number of coatings developed for Mg for biomedical applications. The Mg substrates were high-purity (HP) Mg and ME10, an alloy recently developed for improved extrudability. The research utilized the new fishing-line specimen configuration to allow direct comparison to our recent in vivo and in vitro measurements. The in vitro measurements were immersion tests of fishing-line specimens immersed in Nor's solution at 37 °C. Tests of substantial duration are needed because the corrosion rates of uncoated samples are low. Nor's solution is the designation given to Hank's solution through which CO2 is bubbled at a partial pressure of 0.009 atm. In this solution, pH is maintained constant by the interaction of CO2 and the bicarbonate ions in the solution. This is the same buffer as that which maintains the pH of blood. Coatings examined were: (i) an anodization using a bio-friendly alkaline electrolyte consisting of phosphate, borate, and metasilicate, (ii) octyltrimethoxysilane (OSi), (iii) 1,2-bis[triethoxysilyl]ethane (BTSE), (iv) anodization+OSi, and (v) anodization + BTSE. The performance of coated samples was comparable to or better than that of the uncoated samples, and there was a substantially better performance for the ME10 samples after anodization+OSi. Reasons for the various performances are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Interconnected microspheres of V2O5 composed of ultra-long nanobelts are synthesized in an environmental friendly way by adopting a conventional anodization process combined with annealing. The synthesis process is simple and low-cost because it does not require any additional chemicals or reagents. Commercial fish-water is used as an electrolyte medium to anodize vanadium foil for the first time. Electron microscopy investigation reveals that each belt consists of numerous nanofibers with free space between them. Therefore, this novel nanostructure demonstrates many outstanding features during electrochemical operation. This structure prevents self-aggregation of active materials and fully utilizes the advantage of active materials by maintaining a large effective contact area between active materials, conductive additives, and electrolyte, which is a key challenge for most nanomaterials. The electrodes exhibit promising electrochemical performance with a stable discharge capacity of 227 mAh·g–1 at 1C after 200 cycles. The rate capability of the electrode is outstanding, and the obtained capacity is as high as 278 at 0.5C, 259 at 1C, 240 at 2C, 206 at 5C, and 166 mAh·g–1 at 10C. Overall, this novel structure could be one of the most favorable nanostructures of vanadium oxide-based cathodes for Li-ion batteries. [Figure not available: see fulltext.]