18 resultados para Valves.

em Deakin Research Online - Australia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new genus and species, Linshuichonetes elfinis, belonging to the Rugosochonetidae, is described from the Early Permian (Late Artinskian or early Kungurian) Liangshan Formation of the Yangtze block. The new genus is defined externally by the presence of fine, but delayed, capillation and a weak or absent median sulcus and fold and by the presence of a distinct posteromedian sinus on the ventral umbo; and internally by a lack of median, lateral and accessory septa in the dorsal interior; absence of vascular trunks in the ventral interior and the presence of distinct radiating rows of papillae in the interior of both valves, particularly an unusual clustered arrangement of papillae on the posteromedian portion of the dorsal interior. The local environment during the deposition of the Liangshan Formation appears to have been a restricted tidal flat or lagoon which experienced frequent sealevel fluctuations associated with the onset of the Yanghsingian transgression. The new species, L. elfinis, appears to have several morphological adaptations enabling successful exploitation of this environment. It was typically a very small and thin-valved species with a high surface area to volume ratio, an advantage in an oxygen restricted environment. The small size and numerous body spinules would have aided individuals to remain suspended at the top of the fine, soft substrate. It also dominated the brachiopod assemblage in the Liangshan Formation, comprising up to 94%of specimens within a bed. These factors indicate that the new species appears to be an opportunistic species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Loxocythere (Novoloxocythere) pelius subgen. et sp. nov. is described from Upper Miocene strata of the Port Phillip and Western Port Basins. Victoria. It has its acme in shallow open marine facies of latest Miocene (Cheltenhamian) age. This species, along with Loxocythere (Novoloxocythere) kerryswansoni Yassini and Jones, 1995, forms a discrete group of rotund Australian Loxocythere species that possess posterior extremities in both valves that are positioned well above mid carapace height (i.e. adjacent to dorsal margin). This feature along with a sub-triangular inner margin outline, defines a carapace shape that is distinct from that of rotund species of Loxocythere (loxocythere) Hornibrook, 1952 and Antarctiloxoconcha Hartmann, 1986. The type species of Antarctiloxoconcha – A.frigida (Neale. 1967), possesses internal carapace features that are very similar to the type species of Loxocythere - L. crassa Hornibrook, 1952. Both have relatively short carapaces and sub-quadrate inner margin outlines with posterior extremities in both valves positioned below mid carapace height. Species of Loxocythere (Novoloxocythere), in particular L. (N.) kerryswansoni, have a carapace shape that is transitional between Loxocythere and Loxoreticulatum Benson, 1964. Species of Loxoreticulatum generally possess a sub-parallelogram shaped carapace/inner margin and arched median hinge element. The latter feature is distinct from the mostly straight median hinge elements of Loxocythere (Loxocythere) and Loxocythere (Novoloxocythere) species. Species of Loxocythere (Novoloxocythere) are also readily distinguishable from relatively elongate species of Loxocythere, such as L. (L.) hornibrooki McKenzie, 1967, as the latter possess long (for genus), sub-rectangular shaped carapaces/inner margin outlines and posterior extremities below mid height.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The concept of tissue-engineered heart valves offers an alternative to current heart valve replacements that is capable of addressing shortcomings such as life-long administration of anticoagulants, inadequate durability, and inability to grow. Since tissue engineering is a multifaceted area, studies conducted have focused on different aspects such as hemodynamics, cellular interactions and mechanisms, scaffold designs, and mechanical characteristics in the form of both in vitro and in vivo investigations. This review concentrates on the advancements of scaffold materials and manufacturing processes, and on cell–scaffold interactions. Aside from the commonly used materials, polyglycolic acid and polylactic acid, novel polymers such as hydrogels and trimethylene carbonate-based polymers are being developed to simulate the natural mechanical characteristics of heart valves. Electrospinning has been examined as a new manufacturing technique that has the potential to facilitate tissue formation via increased surface area. The type of cells utilized for seeding onto the scaffolds is another factor to take into consideration; currently, stem cells are of great interest because of their potential to differentiate into various types of cells. Although extensive studies have been conducted, the creation of a fully functional heart valve that is clinically applicable still requires further investigation due to the complexity and intricacies of the heart valve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents experimental and computational results obtained on the Ford Barra 190 4.0 litres I6 gasoline engine and on the Ford Falcon car equipped with this engine. Measurements of steady engine performance, fuel consumption and exhaust emissions were first collected using an automated test facility for a wide range of cam and spark timings vs. throttle position and engine speed. Simulations were performed for a significant number of measured operating points at full and part load by using a coupled Gamma Technologies GT-POWER/GT-COOL engine model for gas exchange, combustion and heat transfer. The fluid model was made up of intake and exhaust systems, oil circuit, coolant circuit and radiator cooling air circuit. The thermal model was made up of finite element components for cylinder head, cylinder, piston, valves and ports and wall thermal masses for pipes. The model was validated versus measured steady state air and fuel flow rates, cylinder pressure parameters, indicated and brake mean effective pressures, and temperature of metal, oil and coolant in selected locations. Computational results agree well with experiments, demonstrating the ability of the approach to produce fairly accurate steady state maps of BMEP and BSFC, as well as to optimize engine operation changing geometry, throttle position, cam and spark timing. Measurements of the transient performance and fuel consumption of the full vehicle were then collected over the NEDC cycle. Simulations were performed by using a coupled Gamma Technologies GT-POWER/GT-COOL/GT-DRIVE model for instantaneous engine gas exchange, combustion and heat transfer and vehicle motion. The full vehicle model is made up of transmission, driveshaft, axles, and car components and the previous engine model. The model was validated with measured fuel flow rates through the engine, engine throttle position, and engine speed and oil and coolant temperatures in selected locations. Instantaneous engine states following a time dependent demand for torque and speed differ from those obtained by interpolating steady state maps of BSFC vs. BMEP and speed. Computational results agree well with experiments, demonstrating the utility of the approach in providing a more accurate prediction of the fuel consumption over test cycles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Arterial bypass and heart valve replacements are two of the most common surgical treatments in cardiovascular surgery today. Currently, artificial materials are used as substitute for these cardiac tissues. However, these foreign materials do not have the ability to grow, repair or remodel and are thrombogenic, leading to stenosis. With the aid of tissue engineering, it is possible to develop functional identical copies of healthy heart valves and arteries, which are biocompatible. Although much effort has been made into this area, there are still inconsistencies with respect to
endothelialisation and cell retention on synthetic biological grafts. These variations may be attributed to differences in factors such as cell seeding density, incubation periods and effects of shear stress. In this study, we have compared the endothelialisation and cell retention between gelain chitosan-coated electrospun polyurethane (PU), poly (lactide co-glycolide) (PGA/PLA) and collagen-coated pericardium. Endothelial cells adhered to all of the materials as early as 1–day post seeding. After 7-day of seeding, the coverage on PU was almost 45% and that on PGA/PLA was about 25% and the least was on collagen-coated pericardium of approximately 15%. It was observed that the PU showed superior cell coverage and cell retention in comparison to the PGA/PLA and collagen-coated pericardium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction of tissue-engineered parts such as heart valves and arteries requires more than just the seeding of cells onto a biocompatible/biodegradable polymeric scaffold. It is essential that the functionality and mechanical integrity of the cell-seeded scaffold be investigated in vitro prior to in vivo implantation. The correct hemodynamic conditioning would lead to the development of tissues with enhanced mechanical strength and cell viability. Therefore, a bioreactor that can simulate physiological conditions would play an important role in the preparation of tissue-engineered constructs. In this article, we present and discuss the design concepts and criteria, as well as the development, of a multifunctional bioreactor for tissue culture in vitro. The system developed is compact and easily housed in an incubator to maintain sterility of the construct. Moreover, the proposed bioreactor, in addition to mimicking in vivo conditions, is highly flexible, allowing different types of constructs to be exposed to various physiological flow conditions. Initial verification of the hemodynamic parameters using Laser doppler anemometry indicated that the bioreactor performed well and produced the correct physiological conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the study, we investigate whether the expressions of heat shock protein (hsp)60 (a potential autoantigen) and the stress-inducible form of cytoprotector hsp70 are correlated with the development of atherosclerotic lesions in the aortic tree of apolipoprotein E–deficient (apoE-/-) mice. The apoE-/- mouse model is advantageous because the stress-inducible form of hsp70 is not constitutively expressed in mice, unlike primates; hence, tissues under stress can be clearly defined. Both mammalian hsps were detected newly expressed (before mononuclear cell infiltration) on aortic valves and endothelia at lesion-prone sites of 3-week-old apoE-/- mice. In 8- and 20-week-old mice, they were strongly and heterogeneously expressed in early to advanced fibrofatty plaques, with levels correlating with lesion severity. Expression was markedly downregulated in advanced collagenous, acellular, calcified plaques of 40- and 69-week-old mice and was absent in control aortas of normocholesterolemic wild-type (apoE+/+) mice. Western blot analysis of tissue homogenates confirmed the temporal expression of the hsps. Double immunostaining revealed that both hsps were expressed by lesional endothelial cells, macrophages, smooth muscle cells, and CD3+ T lymphocytes. This study provides evidence that hsp60 and hsp70 are temporally expressed on all major cell types in lesion-prone sites during atherogenesis, suggesting that few cells escape the toxic environment of the atherosclerotic plaque.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents design, construction, and evaluation of a micropump for drug delivery applications. The proposed micropump consists of three components: fluidics, electronics, and software. The fluidics component includes a silicone elastic diaphragm, a microservo, housing and two check valves. The diaphragm is modeled and simulated to establish its geometrical specifications. The housing is built using a rapid prototype machine. The electronics component consists of a microcontroller, a microswitch array, a simple display and a power unit. The software component is written in C and receives inputs from user, controls the microservo speed and displays the programmed speed. A number of experiments are conducted to evaluate the performance and capabilities of the micropump. The experiments focus on measurement of flow rate, dosage and duration of operation. A discussion of the performance and capabilities of the developed micropump is also given.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A medium scale Mung Bean starch factory was taken in this study to assess the pollution caused by various streams in starch and noodle factories, and to provide the basic information for wastewater management in them. This study shows that the wastewater from starch processing unit with 46~54 tons of production capacity is the main polluting source, contained high values of COD and SS. Also the specific water consumption to process one ton Mung Bean in 16~25m3 is higher that theoretically required one. Methods have been proposed for minimizing and treating the wastewater produced by the factory to overcome the pollution problems. One of the alternatives is to use water in a controlled way by making optimum flow rates on the tab valves, in which water consumption can be brought down. However, bio-treatability of wastewater can be used for treating the total wastewater due to the suitability in characteristics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Seawater desalination has significantly developed towards membrane technology than phase change process during last decade. Seawater reverse osmosis (SWRO) in general is the most familiar process due to higher water recovery and lower energy consumption compared to other available desalination processes. Despite major advancements in SWRO technology, desalination industry is still facing significant amount of practical issues. Therefore, the potentials and problems faced by current SWRO industries and essential study areas are discussed in this review for the benefit of desalination industry. It is important to consider all the following five components in SWRO process i.e. (1) intake (2) pre-treatment (3) high pressure pumping (4) membrane separation (performance of membranes and brine disposal) and (5) product quality. Development of higher corrosion resistant piping materials or coating materials, valves, and pumps is believed to be in higher research demand. Furthermore, brine management, that includes brine disposal and resource recovery need further attention. Pre-treatment sludge management and reduced cleaning in place flush volume will reduce the capital costs associated with evaporation ponds and the maintenance costs associated with disposal and transportation reducing the unit cost of water. © 2013 Springer Science+Business Media Dordrecht.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Valves are one of the key components in microfluidic devices to control the fluid flow. In this paper we introduce a novel manual pin-valve which can operate in both analogue (partially close) and digital (on/off) states. We also demonstrate implementation of this pin-valve in a hydrodynamic flow focusing (HFF) device. © The Royal Society of Chemistry 2014.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

 While data processing methods in metabolomic studies often work with 'n' number of dimensions, analytical techniques, with the notable exception of NMR, have mostly stuck only to one. Peak overlap continues to be a problem and there is an ever-present demand to maximize the number of metabolites that can be separated and identified in a single run. One method that might help to overcome these issues is multidimensional liquid chromatography, which uses two columns of different phases. A sequential collection of aliquots is made from the first column and reinjected onto a second, and the resulting data are then plotted in 2D or 3D space. The total peak capacity of such a system is the combined peak capacities of each column. The 'offline' version of this technique, using a fraction collector, was introduced over 30 years ago but with recent advances in instrumentation and software, particularly the 'online' approach using automated switching valves, has led to increasing interest in the technique. Both offline and online methods can be carried out as a comprehensive procedure, or via 'heart-cutting', in which only specific peaks are analysed in the second dimension. Past applications include proteomics, natural product chemistry, forensic science and pharmaceutical analysis. These successes are likely to be built on in the future as new column chemistries and bio-informatic approaches are developed. In this review an overview of the theory of twodimensional liquid chromatography is presented, its potential in the field of metabolomics is assessed and predictions for future research directions are made.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a simple, environmentally friendly approach to fabricating superhydrophobic coatings with pH-induced wettability transition. The coatings are prepared from a mixture of silica nanoparticles and decanoic acid-modified TiO2. When the coating is applied on cotton fabric, the fabric turns superhydrophobic in air but superoleophilic in neutral aqueous environment. It is permeable to oil fluids but impermeable to water. However, when the coated fabric is placed in basic aqueous solution or ammonia vapor, it turns hydrophilic but underwater superoleophobic, thus allowing water to penetrate through but blocking oil. Therefore, such a unique, selective water/oil permeation feature makes the treated fabric have capability to separate either oil or water from a water-oil mixture. It may be useful for development of smart oil-water separators, microfluidic valves, and lab-on-a-chip devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The impact of early valve surgery (EVS) on the outcome of Staphylococcus aureus (SA) prosthetic valve infective endocarditis (PVIE) is unresolved. The objective of this study was to evaluate the association between EVS, performed within the first 60 days of hospitalization, and outcome of SA PVIE within the International Collaboration on Endocarditis-Prospective Cohort Study. METHODS: Participants were enrolled between June 2000 and December 2006. Cox proportional hazards modeling that included surgery as a time-dependent covariate and propensity adjustment for likelihood to receive cardiac surgery was used to evaluate the impact of EVS and 1-year all-cause mortality on patients with definite left-sided S. aureus PVIE and no history of injection drug use. RESULTS: EVS was performed in 74 of the 168 (44.3%) patients. One-year mortality was significantly higher among patients with S. aureus PVIE than in patients with non-S. aureus PVIE (48.2% vs 32.9%; P = .003). Staphylococcus aureus PVIE patients who underwent EVS had a significantly lower 1-year mortality rate (33.8% vs 59.1%; P = .001). In multivariate, propensity-adjusted models, EVS was not associated with 1-year mortality (risk ratio, 0.67 [95% confidence interval, .39-1.15]; P = .15). CONCLUSIONS: In this prospective, multinational cohort of patients with S. aureus PVIE, EVS was not associated with reduced 1-year mortality. The decision to pursue EVS should be individualized for each patient, based upon infection-specific characteristics rather than solely upon the microbiology of the infection causing PVIE.