48 resultados para VOLTAMMETRY

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adsorption of tributyltin onto materials commonly used for the construction of sampling and analytical equipment from aqueous solutions of varying ionic composition has been examined. The adsorption appears to be controlled by non-polar interactions between tributyltin and the surface involved. Since the speciation and hence polarity of tributyltin is affected by the ionic composition of the medium, the extent of adsorption is affected by the salinity and pH of a sample. The adsorption is rapid and, unless strategies are adopted to eliminate its effects, may render analytical results invalid. The electrochemistry of tributyltin, dibutyltin and monobutyltin, individually and in mixtures, has been investigated in aqueous media at mercury electrodes. The basic electrochemistry of each compound is summarised by the reaction BunSn (4-n)+ + (4-n)e- right left harpoons BunSn where n is the number of butyl groups attached to the tin atom. However, the electrochemistry of each compound is largely confined to the surface of the mercury electrode, and the simplicity of the above reaction is disrupted by polymerisation reactions and by butyl exchange processes occurring with the mercury electrode. When mixtures of butyltin compounds are present, the various processes that occur for each individual compound interfere with each other. A direct voltaminetric method for the determination of butyltin compounds in natural waters is therefore probably not possible.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An electrochemical sensor for the detection of Cu2+ is reported which incorporates poly-l-aspartic acid (PLAsp) with 32–96 aspartate units as a selective ligand for the metal ion. PLAsp is covalently attached to a gold electrode modified with a monolayer of 3-mercaptopropionic acid using carbodiimide coupling via an N-hydroxysuccinimide (NHS) ester intermediate. The acid side groups and deprotonated peptide nitrogens on two aspartate moieties are thought to be primarily responsible for chelation of Cu2+, which remains bound when reduced to Cu+. A consequence of the multiple binding points that are available with a polypeptide is the low detection limit. The lowest concentration detected was 3 nM (0.2 ppb) achieved with Osteryoung square wave voltammetry. This detection limit compares favourably with that of ICP-OES and previously reported cysteine-modified electrodes. Analysis of tap and lake water samples using the PLAsp-modified electrode agreed well with ICP-OES analysis of the same samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrochemical studies on the Fc + e− Fc+ (Fc = ferrocene) process have been undertaken via the oxidation of Fc and reduction of Fc+ as the hexafluorophosphate (PF6−) or tetrafluoroborate (BF4−) salts and their mixtures in three ionic liquids (ILs) (1-butyl-1-methylpyrrolidinium bis[(trifluoromethyl)sulfonyl]imide, 1-butyl-3-methylimidazolium tetrafluoroborate, and 1-butyl-3-methylimidazolium hexafluorophosphate). Data obtained at macro- and microdisk electrodes using conventional dc and Fourier-transformed large-amplitude ac (FT-ac) voltammetry reveal that diffusion coefficients for Fc and Fc+ differ significantly and are a function of the Fc and Fc+ concentration, in contrast to findings in molecular solvents with 0.1 M added supporting electrolyte media. Thus, the Faradaic currents associated with the oxidation of Fc (Fc0/+) and reduction of FcPF6 or FcBF4 (Fc+/0) when both Fc and Fc+ are simultaneously present in the ILs differ from values obtained when individual Fc and Fc+ solutions are used. The voltammetry for both the Fc0/+ and Fc+/0 processes exhibited near-Nernstian behavior at a glassy carbon macrodisk electrode and a platinum microdisk electrode, when each process was studied individually in the ILs. As expected, the reversible formal potentials (E°′) and diffusion coefficients (D) at 23 ± 1 °C were independent of the electrode material and concentration. However, when Fc and FcPF6 or FcBF4 were both present, alterations to the mass transport process occurred and apparent D values calculated for Fc and Fc+ were found to be about 25−39% and 32−42% larger, respectively, than those determined from individual solutions. The apparent value of the double layer capacitance determined by FT-ac voltammetry from individual and mixed Fc and Fc+ conditions at the GC electrode was also a function of concentration. Double layer capacitance values increased significantly with the concentration of Fc and FcPF6 or FcBF4 when species were studied individually or simultaneously, but had a larger magnitude under conditions where both species were present. Variation in the structure of the ILs and hence mobilities of the ionic species, when Fc and FcPF6 or FcBF4 are simultaneously present, is considered to be the origin of the nonadditivity of the Faradaic currents and variation in capacitance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Unexpected nonadditivity of currents encountered in the electrochemistry of mixtures of ferrocene (Fc) and cobaltocenium cation (Cc+) as the PF6 - salt has been investigated by direct current (dc) and Fourier-transformed alternating current (ac) cyclic voltammetry in two aprotic (1-butyl-3-methylimidazolium tetrafluoroborate and 1-butyl-3-methylimidazolium hexafluorophosphate) and three protic (triethylammonium formate, bis(2-hydroxyethyl)ammonium acetate, and triethylammonium acetate) ionic liquids (ILs). The voltammetry of the individual Fc0/+ and Cc+/0 couples always exhibits near-Nernstian behavior at glassy carbon and gold electrodes. As expected for an ideal process, the reversible formal potentials and diffusion coefficients at 23 ( 1 °C in each IL determined from measurement on individual Fc and Cc+ solutions were found to be independent of electrode material, concentration, and technique used for the measurement. However, when Fc and Cc+ were simultaneously present, the dc and ac peak currents per unit concentration for the Fc0/+ and Cc+/0 processes were found to be significantly enhanced in both aprotic and protic ILs. Thus, the apparent diffusion coefficient values calculated for Fc and Cc+ were respectively found to be about 25 and 35% larger than those determined individually in the aprotic ILs. A similar change in the Fc0/+ mass transport characteristics was observed upon addition of tetrabutylammonium hexafluorophosphate (Bu4NPF6), and the double layer capacitance also varied in distinctly different ways when Fc and Cc+ were present individually or in mixtures. Importantly, the nonadditivity of Faradaic current is not associated with a change in viscosity or from electron exchange as found when some solutes are added to ILs. The observation that the 1H NMR T1 relaxation times for the proton resonance in Cc+ also are modified in mixed systems implies that specific interaction with aggregates of the constituent IL ionic species giving rise to subtle structural changes plays an important role in modifying the mass transport, double layer characteristics, and dynamics when solutes of interest in this study are added to ILs. Analogous voltammetric changes were not observed in studies in organic solvent media containing 0.1 M added supporting electrolyte. Implications of the nonadditivity of Faradaic and capacitance terms in ILs are considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To meet the urgent requirement of determining trace Pb2+ and Cd2+ in seawater on site, herein we developed a simple but novel electrochemical method, named as double stripping voltammetry, using only a portable heavy metal analyzer. The proposed method consisted of three steps: First, the targeted heavy metal ions in bulk solution were concentrated onto an ionic liquid-graphite-based paste working electrode (ILGPE), which exhibits a dramatic ability of accumulation, by electrodeposition in the presence of Bi3+. Second, the three-electrode arrangement, including the ILGPE loaded with the reduced products, was transferred into 1.0mL acetate buffer solution, followed by a stripping procedure. Third, the measurement was performed with the other stripping voltammetry procedure by using a glassy carbon electrode as working electrode. Under optimum conditions, the linear range values for Pb2+ and Cd2+ in seawater were 0.2-3.2 μg/L and 0.1-3.2 μg/L, respectively. The concentrations of Pb2+ and Cd2+ in five real samples collected from coastal sites of Qingdao City were determined on site, and the results were in good agreement with that obtained with the atomic absorption spectroscopy method. In addition, the analytical performance of working electrode modified with Bi film by in situ mode was investigated in comparison with that by ex situ mode. The results showed that the in situ mode was much better than the ex situ one.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The reductive voltammetry of the photovoltaic sensitizer [(H2-dcbpy)2Ru(NCS)2] (H2-dcbpy=2,2′-bipyridine-4,4′-dicarboxylic acid) and [(H3-tctpy)Ru(NCS)3]− (H3-tctpy=2,2′:6′,2″-terpyridine-4,4′,4″-tricarboxylic acid) has been investigated in acetone. Significant surface interactions at both platinum and glassy carbon electrodes occur at 0.6 V prior to the reversible potential expected for ligand-based reduction process of the fully protonated acids. The origin of the surface interactions are attributed to the acid–base behaviour of the compounds, combined with overall deprotonation and reduction to hydrogen, since repetitive cycling of the potential reveals well-defined reversible reduction processes in the negative potential range, resulting from formation of doubly deprotonated [(H-dcbpy−)2Ru(NCS)2]2− and singly deprotonated [(H2-tctpy−)Ru(NCS)3]2−, respectively. The extent of the surface interactions has been estimated by electrochemical quartz crystal microbalance and chronocoulometric measurements. Under certain conditions, a thick conducting polymer consisting of several hundred monolayers is formed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A class of new conjugated copolymers containing a donor (thiophene)−acceptor (2-pyran-4-ylidene-malononitrile) was synthesized via Stille coupling polymerization. The resulting copolymers were characterized by 1H NMR, elemental analysis, GPC, TGA, and DSC. UV−vis spectra indicated that the increase in the content of the thiophene units increased the interaction between the polymer main chains to cause a red-shift in the optical absorbance. Cyclic voltammetry was used to estimate the energy levels of the lowest unoccupied molecular orbital (LUMO) and the highest occupied molecular orbital (HOMO) and the band gap (Eg) of the copolymers. The basic electronic structures of the copolymers were also studied by DFT calculations with the GGA/B3LYP function. Both the experimental and the calculated results indicated an increase in the HOMO energy level with increasing the content of thiophene units, whereas the corresponding change in the LUMO energy level was much smaller. Polymer photovoltaic cells of a bulk heterojunction were fabricated with the structure of ITO/PEDOT/PSS (30 nm)/copolymer−PCBM blend (70 nm)/Ca (8 nm)/Al (140 nm). It was found that the open-circuit voltage (Voc) increased (up to 0.93 V) with a decrease in the content of thiophene units. Although the observed power convention efficiency is still relatively low (up to 0.9%), the corresponding low fill factor (0.29) indicates considerable room for further improvement in the device performance. These results provided a novel concept for developing high Voc photovoltaic cells based on donor-π-acceptor conjugated copolymers by adjusting the donor/acceptor ratio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[No Abstract]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A large part of the work presented in this thesis describes the development and use of a novel electrochemical detector designed to allow the electrochemical characterisation of compounds in flowing solution by means of cyclic voltammetry. The detector was microprocessor controlled, which provides digital generation of the potential waveform and collection of data for subsequent analysis. Microdisk working electrodes are employed to permit both thermodynamic and kinetically controlled processes to be studied under steady-state conditions in flowing solutions without the distortion or hysteresis normally encountered with larger sized electrodes. The effect of electrode size, potential scan rate, and solution flow rate are studied extensively with the oxidation of ferrocene used as an example of a thermodynamically controlled process and a series of catecholamines as examples of a kinetically controlled process. The performance of the detector was best demonstrated when used as a HPLC post-column detector. The 3-dimensional chromatovoltammograms obtained allow on-line characterisation of each fraction as it elutes from the column. The rest of the work presented in this thesis involves the study of the oxidative degradation pathway of dithranol. The oxidative pathway was shown to involve a complex free radical mechanism, dependent on the presence of both oxygen and, in particular light. The pathway is further complicated by the fact that dithranol may exist in either a keto or enol form, the enol being most susceptible to oxidation. A likely mechanism is proposed from studies performed with cyclic voltammetry and controlled potential electrolysis, then defined by subsequent kinetic studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An understanding of the rate and the mechanism of reaction is of fundamental importance in the many facets of chemistry. Electrochemical systems are further complicated by the heterogeneous boundary, between the solution and the electrode, that the electron passes through before any electrochemical reaction can take place. This thesis concerns the development of methods for analysing electrode kinetics. One part involves the further development of the Global Analysis procedure to include electrodes with a spherical geometry which are traditionally the most popular form of electrodes. Simulated data is analysed to ascertain the accuracy of the procedure and then the known artifacts of uncompensated solution resistance and charging current are added to the simulated data so that the effects can be observed. The experimental analysis of 2-methyl-2-nitropropane is undertaken and comparisons are made with the Marcus-Hush electrochemical theories concerning electrode kinetics. A related section explores procedures for the kinetic analysis of steady state voltammetric data obtained at microdisc electrodes. A method is proposed under the name of Normalised Steady State Voltammetry and is tested using data obtained from a Fast Quasi-Explicit Finite Difference simulation of diffusion to a microdisc electrode. In a second area of work using microelectrodes, the electrochemical behaviour of compounds of the general formula M(CO)3(η3 - P2P1) where M is either Cr, Mo or W and P2P' is bis(2-diphenylphosphinoethyl)phenylphosphine) is elucidated. The development of instrumentation and mathematical procedures relevant to the measurement and quantitation of these systems is also investigated. The tungsten compound represents the first examples where the 17-electronfac+ and mer+ isomers are of comparable stability.