46 resultados para Ultrasonic velocity

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two questions emerge from the literature concerning the perceptual-motor processes underlying the visual regulation of step length. The first concerns the effects of velocity on the onset of visual control (VCO), when visual regulation of step length begins during goal-directed locomotion. The second concerns the effects of different obstacles such as a target or raised surface on step length regulation. In two separate experiments, participants (Experiment 1 & 2: n=12, 6 female, 6 male) walked, jogged, or sprinted towards an obstacle along a 10 m walkway, consisting of two marker-strips with alternating black and white 0.50 m markings. Each experiment consisted of three targeting or obstacle tasks with the requirement to both negotiate and continue moving (run-through) through the target. Five trials were conducted for each task and approach speed, with trials block randomised between the six participants of each gender. One 50 Hz video camera panned and filmed each trial from an elevated position, adjacent to the walkway. Video footage was digitized to deduce the gait characteristics. Results for the targeting tasks indicate a linear relationship between approach velocity and accuracy of final foot placement (r=0.89). When foot placement was highly constrained by the obstacle step length shortened during the entire approach. VCO was found to occur at an earlier tau-margin for lower approach velocities for both experiments, indicating that the optical variable ‘tau' is affected by approach velocity. A three-phase kinematic profile was found for all tasks, except for the take-off board condition when sprinting. Further research is needed to determine whether this velocity affect on VCO is due to ‘whole-body' approach velocity or whether it is a function of the differences between gait modes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When human observers move forward and rotate their eyes, a complex pattern of light flows across the retina. This pattern is referred to as retinal flow. A model has been proposed to explain how humans perceive their direction of self-movement (or heading) from (1) static depth, (2) direction of image motion, and (3) whether image velocity undergoes acceleration or deceleration (Wang & Cutting, 1999). However, findings from past research in which sparse or minimalist stimuli were used have suggested that not all of the information to which participants are sensitive is captured within the scope of this model. In particular it has been suggested that the magnitude or size of image velocity change may be of significance beyond simply whether image velocity could be categorized as speeding up (i.e., accelerating) or slowing down (i.e., decelerating). In two experiments, the influence of this factor on heading judgments under minimal conditions was investigated. Evidence was found in support of the idea that the rate of image velocity change can influence judgments of the direction of self-movement in minimalist conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel fabrication process for advanced composite components—the QuicktepTM process was described. 2/2 twill weave MTM56/CF0300 carbon epoxy composite laminates were manufactured by the Quickstep and the autoclave processes. The response of these laminates to drop-weight low velocity impact at energy levels ranging from 5 to 30 J was investigated. It was found that the laminates fabricated by the Quickstep had better impact damage tolerance than those fabricated by the autoclave. Optical microscopy revealed extensive matrix fracture in the center of the backside of the autoclave laminates indicating the more brittle property of the epoxy matrix cured by the autoclave process. Interfacial shear strength (IFSS) for two composite systems were measured by micro–debond experiments. The MTM56/CF0300 material cured by the Quickstep showed stronger fibre matrix adhesion. Since the thickness and density of the impact targets produced by two processes were different, finite element analysis (FEA) was performed to study the effect of these factors on the impact response. The simulation results showed that the difference in thickness and density affects the stress distribution under impact loading. Higher thickness and lower density caused by processing lead to less endurance to drop weight impact loading. Therefore the better performance of Quickstep laminates under impact loading was not due to the thickness and density change, but resulted from stronger mechanical properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe how object estimation by a stationary or a non-stationary camera can be improved using recently-developed robust estimation ideas. The robustness of vision-based systems can be improved significantly by employing a Robust Extended Kalman Filter (REKF). The system performance is also enhanced by increasing the spatial diveristy in measurements via employing additional cameras for video capture. We describe a normal-flow based image segmentation technique to identify the object for the application of our proposed state estimation technique. Our simulations demonstrate that dynamic system modelling coupled with the application of a REKF significantly improves the estimation system performance, especially when large uncertainties are present.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aortic pulse wave velocity (aPWV), a noninvasive measure of vascular stiffness, is an independent predictor of cardiovascular disease both before and in overt vascular disease. Its characteristics in early life and its relationship to maternal factors have hardly been studied. To test the hypothesis that infant aPWV was positively related to maternal anthropometry and blood pressure (BP) at 28 weeks gestation, after adjusting for neonatal anthropometry and BP, 148 babies born in Manchester were measured 1 to 3 days after birth. A high reproducibility of aPWV, assessed in 30 babies within 3 days of birth, was found with a mean difference between occasions of –0.04 m/s (95% CI: –0.08 to 0.16 m/s). Contrary to our hypothesis, a significant inverse relation was found between neonatal aPWV (mean: 4.6 m/s) and maternal systolic BP (mean: 108.9 mm Hg; r=–0.57; 95% CI: –0.67 to –0.45) but not maternal height nor weight. Neonatal aPWV was positively correlated with birth length, birth weight, and systolic BP. In multiple regression, neonatal aPWV remained significantly inversely associated with maternal systolic BP (adjusted ß coefficient: –0.032; 95% CI: –0.040 to –0.024; P<0.001), after adjustment for maternal age, birth weight, length, and neonatal BP (all independently and positively related to aPWV) and for gestational age, maternal weight, and height (unrelated). These results suggest that infant aPWV may be a useful index of infant vascular status, is less disturbing to measure than infant BP, and is sensitive to the gestational environment marked by maternal BP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we use recently developed robust estimation ideas to improve object tracking by a stationary or nonstationary camera. Large uncertainties are always present in vision-based systems, particularly, in relation to the estimation of the initial state as well as the measurement of object motion. The robustness of these systems can be significantly improved by employing a robust extended Kalman filter (REKF). The system performance can also be enhanced by increasing the spatial diversity in measurements via employing additional cameras for video capture. We compare the performances of various image segmentation techniques in moving-object localization and show that normal-flow-based segmentation yields comparable results to, but requires significantly less time than, optical-flow-based segmentation. We also demonstrate with simulations that dynamic system modeling coupled with the application of an REKF significantly improves the estimation system performance, particularly, when subjected to large uncertainties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To develop a new form of the modified Ashworth scale (MAS) for muscle-tone assessment that combines the MAS score with the passive muscle-stretching velocity during the assessment of muscle tone, resulting in a measure that has higher intertester reliability than the MAS.

Design: Twanty-two volunteer subjects with spinal cord injuries at a tertiary care outpatient and inpatient spinal cord injury rehabilitation center affiliated with a university were recruited for this study.

Results: A decision tree in which V-MAS scores were obtained was developed. The data obtained from three independent raters, when adjusted by means of the V-MAS, showed an excellent interrater reliability.

Conclusions: Results indicated that the V-MAS is a more reliable measure. In addition, the resulting units of the V-MAS, ranging from 0 to 1, are of the same form as pendulum test data. The V-MAS method is quite simple to use because the rater need only measure the angular range and duration of the passive movement to calculate average velocity during the MAS assessment in addition to the normal MAS rating of muscle tone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses a computer-aided methodology for thickness strain analysis (TSA) of sheet metal stampings using geometry and strain information that is extracted from finite element analysis (FEA) results. The system utilises both FEA results and an ultrasonic gauge capability expert system to assist press shop personnel, providing them with capabilities such as optimum measurement point location and an estimate of gauge error. Key advantages of this enhanced TSA methodology are related to overall efficiency and accuracy gains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the use of ultrasonic agitation as a method for reducing felting and area shrinkage during the laundering of wool fabric. Work was conducted to evaluate the changes in fibre and fabric properties after repeated exposure to ultrasonic agitation, and also the effectiveness of ultrasonic treatment to remove common stains. Fabric colour, appearance, tensile strength, dimensional stability and thickness were measured before and after each test. Ultrasonic agitation produced fine cracks in the scale structure of the fibre, but these had negligible effects on the strength and colour when compared to hand washing. Ultrasonic agitation caused less fibre migration than hand washing, with a reduced rate of thickness increase and felting. Ultrasonic agitation increased the level of stain removed from the fabric when compared with hand washing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Macroscopic- and histological-based assessments of gonad condition were compared with ultrasound images to determine the feasibility of this technology as a non-invasive diagnostic tool for identifying sex and assessing maturation status of Murray cod. Four age-classes (1+, 2+, 3+ and 6+ years), were sub-sampled at monthly intervals throughout their annual reproductive cycle and scanned with a 5 MHz linear transducer. An interpretation of sex was made from the resulting images and maximum cross-sectional gonad diameter and area were recorded. Fish were subsequently dissected to confirm gender, and the weights and maturation status of gonads determined and then compared with their respective image profile. Ovaries of females were usually a distinctive feature in ultrasound images, being particularly obvious in older and/or more developed fish. In contrast, the identification of male testis was more problematic. Nonetheless, identifying sex from ultrasound images was consistently achieved by recording the presence/absence of a female ovary (96% total sexing accuracy). Maximum cross-sectional ovary diameter and area were highly correlated with gonad weight (r2 = 0.90 and 0.89, respectively) suggesting that indices of maturation status, comparable to the gonadosomatic index (GSI), can be obtained non-destructively from ultrasound scans of females. A less distinct relationship occurred between these dimensions and weight of testes (r2 = 0.41). Significant increases (P < 0.05) in mean gonad index (GI, calculated from gonad diameter) occurred for most gonad development stages. However, differences in mean GI between maturation stages were confounded by phenotypic variability, indicating that GI may be limited to population level studies. Nevertheless, ultrasound images of ovaries at each development stage were visually distinctive and enabled qualitative evaluations of maturity, thereby complementing quantitative GI assessments. Repeated serial-monitoring of the same population using ultrasound appears to have great potential for tracking maturation-induced changes in broodfish.