14 resultados para Transmission line impedance

em Deakin Research Online - Australia


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper examines the use of overhead power transmission lines as electromagnetic sensors for detecting electric discharges caused by defective power transmission equipment. The experimental study involved the use of a spark gap (point-point configuration) and two HV conductors of different lengths to simulate electric discharge that takes place on transmission line. The experimental results show that large amount of energy are coupled onto the conductors and the amount of electromagnetic energy is dependent on the length of the conductor and the distance between the source and the conductor.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A wide band low actuation capacitive coupling electrostatic RF MEMS switching device is presented in this paper. The device includes a pi-shaped matching architecture containing two switches connected by a high impedance short transmission line. The device can act as a switch for any desired frequency whilst requiring only 12volts for actuation. By optimizing the length and the characteristic impedance of the transmission line, the switch can be tailored for desired frequency bands. The switch is calculated and simulated for Ka to V frequency bands demonstrating excellent improvements of RF characteristics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a new architecture for a high quality tunable MEMS filter that can be used in wireless biomedical signal transceivers. It consists of a π match circuit with two shunt capacitive coupling switches separated by a piece of high impedance short transmission line, and also a series switch placed at the quarter wavelength distance away from the π match circuit. The low actuation voltage and also tunability are important features of the design objective. All portions of the filter can be realized simultaneously. Thus, the filter docs not require any extra steps during its fabrication, and is not costly. The simulation results confirm the good performance of the filter.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper investigates and measures the near end and far end crosstalk in the multiconductor transmission line (MTL) mounted on the PCB by varying the parameters which are associated with physical dimension, characteristic of the substrate and the nature of input signal. With the variation of these factors, the coupling inductance and capacitance vary causing crosstalk. By using the method of moment (MoM), the per unit length parameters are calculated for microstrip lines. Subcircuit model is used to investigate the time domain and frequency domain analysis of near field and far field crosstalk. This parametric investigation is very useful for designing high speed interconnectors on PCB substrates. Some experimental results are presented to validate the analytical findings.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Increasing the capacitance ratio in RF MEMS shunt capacitive switch will increase its RF performance but also raise its actuation voltage. To improve the RF performance of the switch without increasing its capacitance ratio, this paper explores two methods: reducing the LC resonance from the mm-wave into the X-band by using an inductive bridge, and using two short high impedance transmission lines at both ends of the CPW line. Accordingly, this paper presents the design and simulation of an electro-static low actuation voltage and a very high isolation multipurpose switch with a very large bandwidth. The simulation results are presented and discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ionic polymer conductive network composite (IPCNC) actuators are a class of electroactive polymer composites that exhibit some interesting electromechanical characteristics such as low voltage actuation, large displacements, and benefit from low density and elastic modulus. Thus, these emerging materials have potential applications in biomimetic and biomedical devices. Whereas significant efforts have been directed toward the development of IPMC actuators, the establishment of a proper mathematical model that could effectively predict the actuators' dynamic behavior is still a key challenge. This paper presents development of an effective modeling strategy for dynamic analysis of IPCNC actuators undergoing large bending deformations. The proposed model is composed of two parts, namely electrical and mechanical dynamic models. The electrical model describes the actuator as a resistive-capacitive (RC) transmission line, whereas the mechanical model describes the actuator as a system of rigid links connected by spring-damping elements. The proposed modeling approach is validated by experimental data, and the results are discussed. © 2014 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

ust-Noticeable-Differences (JND) as a dead-band in perceptual analysis has been widely used for more than a decade. This technique has been employed for data reduction in hap tic data transmission systems by several researchers. In fact, researchers use two different JND coefficients that are JNDV and JNDF for velocity and force data respectively. For position data, they usually rely on the resolution of hap tic display device to omit data that are unperceivable to human. In this paper, pruning undesirable position data that are produced by the vibration of the device or subject and/or noise in transmission line is addressed. It is shown that using inverse JNDV for position data can prune undesirable position data. Comparison of the results of the proposed method in this paper with several well known filters and some available methods proposed by other researchers is performed. It is shown that combination of JNDV could provide lower error with desirable curve smoothness, and as little as possible computation effort and complexity. It also has been shown that this method reduces much more data rather than using forward-JNDV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

X-ray diffraction line profile analysis has been used to study the microstructure of (Ill) oriented gold and platinum thin films deposited by thermal evaporation and DC magnetron sputtering. In addition to crystallite size broadening, the profiles from these films displayed broadening arising from dislocations. A parallel investigation, using transmission electron microscopy (TEM) was undertaken to study the nature of dislocations formed, and to provide information on the dimensions of the crystallite columns in the films. X-ray data were collected at room temperature to determine the anisotropy of the broadening with (hkl), using a Siemens D5000 powder diffractometer (CuKa radiation) and two high-resolution synchrotron instruments (BM 16 at the ESRF [A=0.35A] and station 2.3 at the Daresbury laboratory. Two approaches to instrument deconvolution were investigated; Fourier deconvolution and fundamental parameters profile fitting, using Lab6 as a reference material to determine the instrument profile function. After removal of the crystallite size broadening contribution from the measured integral breadths, the residual microstrain broadening was modelled assuming dislocations based on a FCC a/2<110>{ Ill} slip system. The results of the X-ray analysis agreed with dark field TEM micrographs, which showed that many of the crystallites contained dislocations of mixed character (screw- edge).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of an in-situ tensometer is described along with preliminary results of x-ray line profiles from copper foils under tensile stress. The tensometer was designed and constructed on the high resolution diffraction instrument, Station 2.3 at the synchrotron radiation source (SRS) Daresbury Laboratory, and is capable of collecting data in either symmetric or asymmetric geometry including transmission and reflection modes. Experiments were carried out using 18 J..Lm thick copper foil up to strain levels of 5 % using both symmetric reflection and symmetric transmission diffraction. All profiles displayed diffraction broadening and asymmetry which increased with strain. In addition, the asymmetry observed in symmetric transmission was associated with extended tails on the low angle side of the profiles, but in symmetric reflection data the opposite asymmetry was observed. In the analysis, the measured profiles were fitted using the software TOPAS, a fundamental parameters approach to profile fitting. The instrumental profile function was characterised and modelled using annealed LaB6 powder. The diffraction broadening was then determined by refining the convolution of a Voigt function, an asymmetric exponential function and a fixed instrument function to reproduce the observed broadened profiles. The integral breadth and asymmetry results display a strong order dependence and increase almost linearly with strain. The results were interpreted by assuming crystallite size broadening in combination with dislocation broadening arising from fcc a/2( 110) {Ill } dislocations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses a simple mathematical model to describe the spread of Streptococcus pneumoniae. We suppose that the transmission of the bacterium is determined by multi-locus sequence type. The model includes vaccination and is designed to examine what happens in a vaccinated population if MLSTs can exist as both vaccine and non vaccine serotypes with capsular switching possible from the former to the latter. We start off with a discussion of Streptococcus pneumoniae and a review of previous work. We propose a simple mathematical model with two sequence types and then perform an equilibrium and (global) stability analysis on the model. We show that in general there are only three equilibria, the carriage-free equilibrium and two carriage equilibria. If the effective reproduction number Re is less than or equal to one, then the carriage will die out. If Re > 1, then the carriage will tend to the carriage equilibrium corresponding to the multi-locus sequence type with the largest transmission parameter. In the case where both multi-locus sequence types have the same transmission parameter then there is a line of carriage equilibria. Provided that carriage is initially present then as time progresses the carriage will approach a point on this line. The results generalize to many competing sequence types. Simulations with realistic parameter values confirm the analytical results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A laboratory-based transmission X-ray diffraction technique was developed to measure elastic lattice strains parallel to the loading direction during in situ tensile deformation. High-quality transmission X-ray diffraction data were acquired in a time frame suitable for in situ loading experiments by application of a polycapillary X-ray optic with a conventional laboratory Cu X-ray source. Based on the measurement of two standard reference materials [lanthanum hexaboride (NIST SRM 660b) and silicon (NIST SRM 640c)], precise instrumental alignment and calibration of the transmission diffraction geometry were realized. These results were also confirmed by the equivalent data acquired using the standard Bragg-Brentano measurement geometry. An empirical Caglioti function was employed to describe the instrumental broadening, while an axis of rotation correction was used to measure and correct the specimen displacement from the centre of the goniometer axis. For precise Bragg peak position and hkil intensity information, a line profile fitting methodology was implemented, with Pawley refinement used to measure the sample reference lattice spacings (d o (hkil)). It is shown that the relatively large X-ray probe size available (7 × 714mm) provides a relatively straightforward approach for improving the grain statistics for the study of metal alloys, where grain sizes in excess of 114μm can become problematic for synchrotron-based measurements. This new laboratory-based capability was applied to study the lattice strain evolution during the elastic-plastic transition in extruded and rolled magnesium alloys. A strain resolution of 2 × 10-4 at relatively low 2θ angles (20-65° 2θ) was achieved for the in situ tensile deformation studies. In situ measurement of the elastic lattice strain accommodation with applied stress in the magnesium alloys indicated the activation of dislocation slip and twin deformation mechanisms. Furthermore, measurement of the relative change in the intensity of 0002 and 10 3 was used to quantify {10 2} 011 tensile twin onset and growth with applied load.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: In the Arkhangelsk region of Northern Russia, multidrug-resistant (MDR) tuberculosis (TB) rates in new cases are amongst the highest in the world. In 2014, MDR-TB rates reached 31.7% among new cases and 56.9% among retreatment cases. The development of new diagnostic tools allows for faster detection of both TB and MDR-TB and should lead to reduced transmission by earlier initiation of anti-TB therapy. STUDY AIM: The PROVE-IT (Policy Relevant Outcomes from Validating Evidence on Impact) Russia study aimed to assess the impact of the implementation of line probe assay (LPA) as part of an LPA-based diagnostic algorithm for patients with presumptive MDR-TB focusing on time to treatment initiation with time from first-care seeking visit to the initiation of MDR-TB treatment rather than diagnostic accuracy as the primary outcome, and to assess treatment outcomes. We hypothesized that the implementation of LPA would result in faster time to treatment initiation and better treatment outcomes.

METHODS: A culture-based diagnostic algorithm used prior to LPA implementation was compared to an LPA-based algorithm that replaced BacTAlert and Löwenstein Jensen (LJ) for drug sensitivity testing. A total of 295 MDR-TB patients were included in the study, 163 diagnosed with the culture-based algorithm, 132 with the LPA-based algorithm.

RESULTS: Among smear positive patients, the implementation of the LPA-based algorithm was associated with a median decrease in time to MDR-TB treatment initiation of 50 and 66 days compared to the culture-based algorithm (BacTAlert and LJ respectively, p<0.001). In smear negative patients, the LPA-based algorithm was associated with a median decrease in time to MDR-TB treatment initiation of 78 days when compared to the culture-based algorithm (LJ, p<0.001). However, several weeks were still needed for treatment initiation in LPA-based algorithm, 24 days in smear positive, and 62 days in smear negative patients. Overall treatment outcomes were better in LPA-based algorithm compared to culture-based algorithm (p = 0.003). Treatment success rates at 20 months of treatment were higher in patients diagnosed with the LPA-based algorithm (65.2%) as compared to those diagnosed with the culture-based algorithm (44.8%). Mortality was also lower in the LPA-based algorithm group (7.6%) compared to the culture-based algorithm group (15.9%). There was no statistically significant difference in smear and culture conversion rates between the two algorithms.

CONCLUSION: The results of the study suggest that the introduction of LPA leads to faster time to MDR diagnosis and earlier treatment initiation as well as better treatment outcomes for patients with MDR-TB. These findings also highlight the need for further improvements within the health system to reduce both patient and diagnostic delays to truly optimize the impact of new, rapid diagnostics.