107 resultados para Spot tests

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have estimated the reliability of performance in a commonly employed exercise test consisting of repeated sprints on a cycle ergometer. Eight recreationally active young men completed a practice trial and three more trials at 3- to 6-day intervals. Each trial consisted of two bouts of 30-s maximal-effort cycling on an electromagnetically braked cycle ergometer; the bouts were separated by 4 min of rest. The typical (standard) errors of measurement for peak and mean power between trials 2 to 4 were 2.5 and 1.7% respectively for the first bout and 1.9 and 1.8% for the second bout. These errors are substantially less than those in previous reliability studies of single 30-s sprint tests, probably because of differences in quality of ergometer. The typical errors for the difference between bouts (i.e., fatigue) for peak power and mean power were 3.0 and 2.5%, respectively. Typical errors for the average of the two bouts were 1.6 and 1.2% for peak and mean power respectively, which are small enough to give adequate precision for moderate treatment effects in studies with modest sample sizes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A compression test with rotating dies was employed to estimate the friction factor between aluminum samples and steel tooling during large plastic deformations. A cylindrical workpiece was compressed under dry and cold conditions. The magnitudes of torque and normal force were measured and
the average friction factor was calculated using the Coulomb friction law. It was found that under certain conditions the friction increased with increasing angular velocity of the die. This finding led to the conclusion that the choice of die rotation speed is important in interpreting the results from the twist compression test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies the effect of the normal distribution assumption on the power and size of the sign test, Wilcoxon's signed rank test and the t-test when used in one-sample location problems. Power functions for these tests under various skewness and kurtosis conditions are produced for several sample sizes from simulated data using the g-and-k distribution of MacGillivray and Cannon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Galvanneal steel is considered to be better for automotive applications than its counterpart, galvanized steel, mainly because of its superior coating and surface properties. Galvanneal steel is produced by hot dipping sheet steel in a bath of molten zinc with small, controlled, levels of aluminium, followed by annealing which creates a Fe-Zn intermetallic layer. This intermetallic layer of the coating improves spot weldability and improves subsequent paint appearance. However, if the microstructure of the coating is not properly controlled and forming parameters are not properly selected, wear of the coating could occur during stamping. Frictional sliding of the sheet between the tool surfaces results in considerable amount of coating loss. An Interstitial Free steel with a Galvanneal coating of nominally 60g/m2 was used for the laboratory experiments. Flat Face Friction (FFF) tests were performed with different forming conditions and lubricants to simulate the frictional sliding in stamping. Glow-Discharge Optical Emission Spectrometry (DG-OES) was used to measure the change in the coating thickness during sliding. Optical microscopy was considered for imaging the surfaces as well as an optical method to compare the changes in the coating thickness during the forming. The change to the Galvanneal coating thickness was found to be a function of forming parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid method for screening drug seizure samples for 3,6-diacetylmorphine (heroin), which consists of a simple hydrolysis procedure and flow-injection analysis with two chemiluminescence reagents, is described. Before hydrolysis, 3,6-diacetylmorphine evokes an intense response with a tris(2,2'-bipyridyl)ruthenium(III) reagent (prepared by dissolving the perchlorate salt in acetonitrile), and a relatively weak chemiluminescence response with a second reagent: potassium permanganate in an aqueous acidic polyphosphate solution. However, the permanganate reagent is extremely sensitive toward the hydrolysis products of 3,6-diacetylmorphine (i.e., 6-monoacetylmorphine and morphine). Some compounds commonly found in drug laboratories may cause false positives with tris(2,2'-bipyridyl)ruthenium(III), but do not produce the markedly increased response with the permanganate reagent after the hydrolysis procedure. The combination of these two tests therefore provides an effective presumptive test for the presence of 3,6-diacetylmorphine, which we have verified with 14 samples obtained from a forensic science laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using a high-frequency data set of the spot Australian dollar/US dollar this study examines the distribution of quotes and returns across the 24 hour trading "day". Employing statistical methods for measuring long-tenn dependence in time-series we find evidence of time-varying dependence and volatility that aligns with the opening and closing of markets. This variation is attributed to the effects of liquidity and the price-discovery actions of dealers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While advanced high strength steels (AHSS) have numerous advantages for the automotive industry, they can be susceptible to interfacial fracture when spot-welded. In this study, the susceptibility of interfacial fracture to spot-weld microstructure and hardness is examined, as well as the corresponding relationships between fatigue, overload performance, and interfacial fracture for a TRIP (transformation induced plasticity) steel. Simple post-weld heat-treatments were used to alter the weld microstructure. The effect on interfacial fracture of diluting the weld pool by welding the TRIP material to non-TRIP steel was examined, along with the effect of altering the base material microstructure. Results show that weld hardness is not a good indicator of either the susceptibility to interfacial fracture, or the strength of the joint, and that interfacial fracture does not necessarily lead to a decrease in strength compared to conventional weld-failure mechanisms, i.e. button pullout. It was also found that while interfacial fracture does affect low cycle to failure behavior, there was no effect on high cycle fatigue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of low-strain deformation behavior on curl and springback in advanced high strength steels (AHSS) was assessed using a bend-under-tension test. The effect of yielding behavior on curl and springback was examined by heat-treating two dual-phase steels to induce yield point elongation, while keeping a relatively constant tensile strength and a constant sheet thickness. A dual-phase and TRIP steel with similar initial thickness and tensile strengths were also examined to investigate the effect of work-hardening on curl and springback. It is shown that while current understanding limits prediction of curl and springback in bending under tension using only the initial sheet thickness and tensile strength, both the yielding and work-hardening behavior can affect the results. Explanations for these effects are proposed in terms of the discontinuous yielding and flow stress in the materials.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose – There are several studies that investigate evidence for mean reversion in stock prices. However, there is no consensus as to whether stock prices are mean reverting or random walk (unit root) processes. The goal of this paper is to re-examine mean reversion in stock prices.
Design/methodology/approach – The authors use five different panel unit root tests, namely the Im, Pesaran and Shin t-bar test statistic, the Levin and Lin test, the Im, Lee, and Tieslau Lagrangian multiplier test statistic, the seemingly unrelated regression test, and the multivariate augmented Dickey Fuller test advocated by Taylor and Sarno.
Findings – The main finding is that there is no mean reversion of stock prices, consistent with the efficient market hypothesis.
Research limitations/implications – One issue not considered by this study is the role of structural breaks. It may be the case that the efficient market hypothesis is contingent on structural breaks in stock prices. Future studies should model structural breaks.
Practical implications – The findings have implications for econometric modelling, in particular forecasting.
Originality/value – This paper adds to the scarce literature on the mean reverting property of stock prices based on panel data; thus, it should be useful for researchers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cathodic arc evaporation (CAE) is a widely used technique for generating highly ionised plasma from which hard, wear-resistant PVD coatings can be deposited. A major drawback of this technique is the emission of micrometer-sized droplets of cathode material from the arc spot, which are commonly referred to as ‘macroparticles’. In this study, the effect of cathode poisoning was investigated as a method to reduce the number of macroparticles in PVD coatings. While the study focuses on the reduction of macroparticles in titanium nitride coatings, the outcomes and key findings can be broadly applied to the cathodic arc process, in particular, for the reduction of macroparticles in more advanced CAE coatings. The results support earlier findings that have shown that poisoning of the cathode can reduce the number of macroparticles emitted from the arc spot. The results of glow discharge optical emission spectroscopy (GD-OES) showed that the titanium content of the coatings varied little between the respective coatings despite changes in the deposition pressure from 0.1 to 1.2 Pa. The GD-OES results also showed the presence of oxide contamination at the surface of the coatings, which was significantly reduced with increasing deposition pressure. The coatings were also deposited onto high-speed steel twist drills to compare the metal-cutting performance when dry drilling a workpiece of cast iron. The results of the drill tests showed that tool life increased with a reduction in the number of macroparticles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate whether the introduction of a national, co-ordinated screening program using the faecal occult blood test represents 'value-for-money' from the perspective of the Australian Government as third-party funder.  Methods: The annual equivalent costs and consequences of a   biennial screening program in 'steady-state' operation were estimated for the Australian population using 1996 as the reference year. Disability-adjusted life years (DALYs) and the years of life lost (YLLs) averted, and the health service costs were modelled, based on the epidemiology and the costs of colorectal cancer in Australia together with the mortality reduction achieved in randomised controlled trials. Uncertainty in the model was examined using Monte Carlo simulation methods. Results: We estimate a minimum or 'base program' of screening those aged 55 to 69 years could avert 250 deaths per annum (95% uncertainty interval 99–400), at a gross cost of $A55 million (95% UI $A46 million to $A96 million) and a gross incremental cost-effectiveness ratio of $A17,000/DALY (95% UI $A13,000/DALY to $A52,000/DALY). Extending the program to include 70 to 74-year-olds is a more effective option (cheaper and higher health gain) than including the 50 to 54-year-olds. Conclusions: The findings of this study support the case for a national program directed at the 55 to 69-year-old age group with extension to 70 to 74-year-olds if there are sufficient resources. The pilot tests recently announced in Australia provide an important opportunity to consider the age range for screening and the sources of uncertainty, identified in the modelled evaluation, to assist decisions on implementing a full national program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate the reliability and validity of five squat-based loading tests that are clinically appropriate for jumper's knee. The loading tests were step up, double leg squat, double leg squat on a 25-degree decline (decline squat), single leg decline squat, and decline hop. Design: Cross-sectional controlled cohort. Subjects without knee pain comprised controls, those with extensor tendon pain comprised the jumper's knee group. Setting: Institutional athlete study group in Australia. Participants: Fifty-six elite adolescent basketball players participated in this study, thirteen comprised the jumper's knee group, fifteen athletes formed a control group. Intervention: Each subject performed each loading test for baseline and reliability data on the first testing day. Subjects then performed three days of intensive (6 h daily) basketball training, after which each loading test was reexamined. Main outcome measures: Eleven point interval scale for pain. Results: The tests that best detected a change in pain due to intensive workload were the single leg decline squat and single leg decline hop. This study found that decline tests have better discriminative ability than the standard squat to detect change in jumper's knee pain due to intensive training. The typical error for these tests ranged from 0.3 to 0.5, however, caution should be exercised in the interpretation of these reliability figures due to relatively low scores. Conclusions: The single leg decline squat is recommended in the physical assessment of adolescent jumper's knee. The decline squat was selected as the best clinical test over the decline hop because it was easier to standardise performance.