7 resultados para Signal variability

em Deakin Research Online - Australia


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Heart rate asymmetry (HRA) is considered as a physiological phenomenon in healthy subjects. In this article, we propose a novel HRA index, Slope Index (SI), to quantify phase asymmetry of heart rate variability (HRV) system. We assessed the performance of proposed index in comparison with conventional (Guzik's Index (GI) and Porta's Index (PI)) HRA indices. As illustrative examples, we used two case studies: (i) differentiate physiologic RR series from synthetic RR series; and (ii) discriminate arrhythmia subjects from Healthy using beat-to-beat heart rate time series. The results showed that SI is a superior parameter than GI and PI for both case studies with maximum ROC area of 0.84 and 0.82 respectively. In contrast, GI and PI had ROC areas {0.78, 0.61} and {0.50, 0.56} in two case studies respectively. We also performed surrogate analysis to show that phase asymmetry is caused by a physiologic phenomena rather than a random nature of the signal. In conclusion, quantification of phase asymmetry of HRV provides additional information on HRA, which might have a potential clinical use to discriminate pathological HRV in future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Animals that breed more than once may face different environmental and physiological conditions at each reproductive event. Costs and benefits of sexual ornaments could therefore vary both within and between breeding seasons. Despite this, the ornaments are often assumed to be fixed, and temporal changes in ornamentation have rarely been investigated. Female two-spotted gobies (Gobiusculus flavescens) have colorful orange bellies when sexually mature and nest-holding males prefer females with more colorful bellies. This nuptial coloration is caused both by the carotenoids-rich gonads being directly visible through the skin and by the chromatophore pigmentation of the abdominal skin. Toward the end of the breeding season, males become rare and females become the more competitive sex. We show that female ornamentation of G. flavescens is a complex multicomponent trait and that the separate components, as well as their interactions, are variable. As gonads matured, they became more colorful while the abdominal skin became more transparent, causing more intense belly coloration in sexually mature females. However, coloration varied greatly also among fully mature females, suggesting that it may not only be a signal of readiness to spawn. Indeed, belly coloration predicted gonad carotenoid concentration, but there were several important seasonal differences in color expression. Females sampled toward the end of the breeding season were more colorful. This was due to seasonal increases in both gonad carotenoid concentration and skin coloration. Thus, at a time when competition over males is stronger and the terminal reproductive event approaches, females appear to invest more in signaling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Respiratory events during sleep induce cortical arousals and manifest changes in autonomic markers in sleep disorder breathing (SDB). Finger photoplethysmography (PPG) has been shown to be a reliable method of determining sympathetic activation. We hypothesize that changes in PPG signals are sufficient to predict the occurrence of respiratory-event-related cortical arousal. In this study, we develop a respiratory arousal detection model in SDB subjects by using PPG features. PPG signals from 10 SDB subjects (9 male, 1 female) with age range 43-75 years were used in this study. Time domain features of PPG signals, such as 1) PWA--pulse wave amplitude, 2) PPI--peak-to-peak interval, and 3) Area--area under peak, were used to detect arousal events. In this study, PWA and Area have shown better performance (higher accuracy and lower false rate) compared to PPI features. After investigating possible groupings of these features, combination of PWA and Area (PWA + Area) was shown to provide better accuracy with a lower false detection rate in arousal detection. PPG-based arousal indexes agreed well across a wide range of decision thresholds, resulting in a receiver operating characteristic with an area under the curve of 0.91. For the decision threshold (PC(thresh) = 25%) chosen for the final analyses, a sensitivity of 68.1% and a specificity of 95.2% were obtained. The results showed an accuracy of 84.68%, 85.15%, 86.93%, and 50.79% with a false rate of 21.80%, 55.41%, 64.78%, and 50.79% at PC(thresh) = 25% or PPI, PWA, Area , and PWA + Area features, respectively. This indicates that combining PWA and Area features reduced the false positive rate without much affecting the sensitivity of the arousal detection system. In conclusion, the PPG-based respiratory arousal detection model is a simple and promising alternative to the conventional electroencephalogram (EEG)-based respiratory arousal detection system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An experimental study has been performed to investigate the ignition delay of a modern heavy-duty common-rail diesel engine run with fumigated ethanol substitutions up to 40% on an energy basis. The ignition delay was determined through the use of statistical modelling in a Bayesian framework this framework allows for the accurate determination of the start of combustion from single consecutive cycles and does not require any differentiation of the in-cylinder pressure signal. At full load the ignition delay has been shown to decrease with increasing ethanol substitutions and evidence of combustion with high ethanol substitutions prior to diesel injection have also been shown experimentally and by modelling. Whereas, at half load increasing ethanol substitutions have increased the ignition delay. A threshold absolute air to fuel ratio (mole basis) of above ~110 for consistent operation has been determined from the inter-cycle variability of the ignition delay, a result that agrees well with previous research of other in-cylinder parameters and further highlights the correlation between the air to fuel ratio and inter-cycle variability. Numerical modelling to investigate the sensitivity of ethanol combustion has also been performed. It has been shown that ethanol combustion is sensitive to the initial air temperature around the feasible operating conditions of the engine. Moreover, a negative temperature coefficient region of approximately 900{1050 K (the approximate temperature at fuel injection) has been shown with for n-heptane and n-heptane/ethanol blends in the numerical modelling. A consequence of this is that the dominate effect influencing the ignition delay under increasing ethanol substitutions may rather be from an increase in chemical reactions and not from in-cylinder temperature. Further investigation revealed that the chemical reactions at low ethanol substitutions are different compared to the high (> 20%) ethanol substitutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Development of the foetal autonomic nervous system can be indirectly understood by looking at the changes in beat to beat variability in foetal heart rates. This study presents Tone-Entropy (T-E) analysis of foetal heart rate variability (HRV) at multiple lags (1–8) to understand the influence of gestational ages (early and late) on the development of the foetal autonomic nervous system (ANS). The analysis was based on foetal electrocardiograms (FECGs) of 46 healthy foetuses of 20–32 weeks (early group) and 22 foetuses of 35–41 weeks (late group). Tone represents sympatho-vagal balance and entropy the total autonomic activities. Results show that tone increases and entropy decreases at all lags for the late foetus group. On the other hand, tone decreases and entropy increases at lags 1–4 in the early foetus group. Increasing tone in late foetuses might represent significant maturation of sympathetic nervous systems because foetuses approaching to delivery period need increased sympathetic activity. T-E could be quantitative clinical index to determine the early foetuses from late ones on the basis of maturation of autonomic nervous system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For clinical use, in electrocardiogram (ECG) signal analysis it is important to detect not only the centre of the P wave, the QRS complex and the T wave, but also the time intervals, such as the ST segment. Much research focused entirely on qrs complex detection, via methods such as wavelet transforms, spline fitting and neural networks. However, drawbacks include the false classification of a severe noise spike as a QRS complex, possibly requiring manual editing, or the omission of information contained in other regions of the ECG signal. While some attempts were made to develop algorithms to detect additional signal characteristics, such as P and T waves, the reported success rates are subject to change from person-to-person and beat-to-beat. To address this variability we propose the use of Markov-chain Monte Carlo statistical modelling to extract the key features of an ECG signal and we report on a feasibility study to investigate the utility of the approach. The modelling approach is examined with reference to a realistic computer generated ECG signal, where details such as wave morphology and noise levels are variable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An off-grid photovoltaic power system requires an energy storage system, especially batteries, for mitigation of variability and intermittency problems, and for assured service reliability and availability. The longevity and reliability of such batteries depend on the effectiveness of the charging system. This paper presents the modelling, simulation and hardware implementation of a four-stage switch-mode charger based on the single-ended primary inductance converter. The digital signal processor based controller implements algorithms for the system's power balance control, maximum power point tracking to improve charging speed and efficiency, four-stage optimal charging, and system's protection. The protection algorithm provides over-charge, overdischarge, over-temperature and short circuit protection capabilities. The proposed system has the following advantages: ability to continuously charge the batteries even at reduced solar irradiation, higher efficiency, and use of adaptive thermally compensated set points for optimum performance. A prototype is built and experimental results are presented to validate the simulation results.