5 resultados para Screws

em Deakin Research Online - Australia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The functional results associated with nonoperative treatment of severely impacted valgus fractures of the proximal part of the humerus are poor, and these injuries are difficult to treat with minimally invasive percutaneous fixation techniques. The aim of this study was to review the functional and radiographic results and complications of a new operative technique in a series of twenty-five patients.

Methods: Over a two-year period, we treated twenty-nine patients with a severely impacted valgus fracture of the proximal part of the humerus. Three patients were lost to follow-up and one died, leaving twenty-five patients who were available for the study. In all of the fractures, the head-shaft angle had been tilted into =160° of valgus and the greater tuberosity was displaced by >1 cm. All patients were treated with open reduction of the fracture, and the space created behind the humeral head was filled with Norian Skeletal Repair System (SRS) bone substitute. The fractures were stabilized with either screws or buttress plate fixation. Associated rotator cuff tears were repaired. All patients underwent functional outcome assessment with use of the Constant, DASH (Disabilities of the Arm, Shoulder and Hand), and SF-36 (Short Form-36) scores at one year, and twelve patients were followed for two years.

Results: All fractures united within the first year, all reductions were maintained, and no patient had signs of osteonecrosis of the humeral head on the latest follow-up radiographs. At one year, the median Constant score was 80 points and the median DASH score was 22 points. The functional results continued to be satisfactory in the twelve patients who were followed for two years. The results in our series were better than those achieved in studies of nonoperative treatment of similar fracture configurations. There were six clinically relevant complications, although none required a reoperation and all six patients had a satisfactory short-term functional outcome.

Conclusions: Internal fixation of severely impacted valgus fractures of the proximal part of the humerus, supplemented by Norian SRS bone substitute to fill the proximal humeral metaphyseal defect, produces good early functional and radiographic outcomes. Additional follow-up will be required to assess whether these initially satisfactory outcomes are maintained over the longer term.

Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The functional results associated with nonoperative treatment of severely impacted valgus fractures of the proximal part of the humerus are poor, and these injuries are difficult to treat with minimally invasive percutaneous fixation techniques. The aim of this study was to review the functional and radiographic results and complications of a new operative technique in a series of twenty-five patients.

Methods: Over a two-year period, we treated twenty-nine patients with a severely impacted valgus fracture of the proximal part of the humerus. Three patients were lost to follow-up and one died, leaving twenty-five patients who were available for the study. In all of the fractures, the head-shaft angle had been tilted into > or = 160 degrees of valgus and the greater tuberosity was displaced by >1 cm. All patients were treated with open reduction of the fracture, and the space created behind the humeral head was filled with Norian Skeletal Repair System (SRS) bone substitute. The fractures were stabilized with either screws or buttress plate fixation. Associated rotator cuff tears were repaired. All patients underwent functional outcome assessment with use of the Constant, DASH (Disabilities of the Arm, Shoulder and Hand), and SF-36 (Short Form-36) scores at one year, and twelve patients were followed for two years.

Results: All fractures united within the first year, all reductions were maintained, and no patient had signs of osteonecrosis of the humeral head on the latest follow-up radiographs. At one year, the median Constant score was 80 points and the median DASH score was 22 points. The functional results continued to be satisfactory in the twelve patients who were followed for two years. The results in our series were better than those achieved in studies of nonoperative treatment of similar fracture configurations. There were six clinically relevant complications, although none required a reoperation and all six patients had a satisfactory short-term functional outcome.

Conclusions: Internal fixation of severely impacted valgus fractures of the proximal part of the humerus, supplemented by Norian SRS bone substitute to fill the proximal humeral metaphyseal defect, produces good early functional and radiographic outcomes. Additional follow-up will be required to assess whether these initially satisfactory outcomes are maintained over the longer term.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose : This study tests the hypothesis that 3-dimensional computed tomography (CT) reconstructions improve interobserver agreement on classification and treatment of coronoid fractures compared with 2-dimensional CT.

Methods : A total of 29 orthopedic surgeons evaluated 10 coronoid fractures on 2 occasions (first with radiographs and 2-dimensional CT and then with radiographs and 3-dimensional CT), separated by a minimum of 2 weeks. Surgeons classified fractures according to the classifications of Regan and Morrey and of O'Driscoll et al., identified specific characteristics, recommended the most appropriate treatment approach, and made treatment recommendations. The kappa multirater measure (κ) was calculated to estimate agreement between observers.

Results : Regardless of the imaging modality used, there was fair to moderate agreement for most of the observations. Three-dimensional CT improved interobserver agreement in Regan and Morrey's classsication (κ3-dimensional = 0.51 vs κ2-dimensional = 0.40; p < .001) and O'Driscoll et al.'s classifications (κ3-dimensional = 0.48 vs κ2-dimensional = 0.42; p = .009). There were trends toward better reliability for 3-dimensional reconstruction in recognition of coronoid tip fractures (κ3-dimensional = 0.19, κ2-dimensional = 0.03; p = .268), comminution (κ3-dimensional = 0.41 vs κ2-dimensional = 0.29; p = .133), and impacted fragments (κ3-dimensional = 0.39 vs κ2-dimensional = 0.27; p = .094), and in surgeons' opinions on the need for something other than screws or plate for surgical fixation (κ3-dimensional = 0.31 vs κ2-dimensional = 0.15; p = .138). Interobserver agreement on treatment approach was better with 2-dimensional CT (κ3-dimensional = 0.27, κ2-dimensional = 0.32; p = .015).

Conclusions :
Three-dimensional CT reconstructions improve interobserver agreement with respect to fracture classification compared with 2-dimensional CT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background
Neck of femur fractures (NOFFs) are a common cause of morbidity and mortality in our community. Minimally displaced intracapsular fractures are treated with internal fixation by a two-hole dynamic hip screw (DHS) or three partially threaded cancellous screws. Data to support the superiority of one are limited. This prospective randomized controlled trial compares outcomes with these two fixation methods.

Methods
We prospectively recruited patients over 50 years, with an acute fracture subcapital NOFF, who walked and lived independently, and were cognitively intact. They were randomized into DHS or cancellous screw groups and followed up for 2 years (overall 75.9%). Outcomes of mortality, revision, loss of fixation, avascular necrosis, surgical complications, WOMAC, Harris hip score and SF-12 were measured.

Results
We recruited 62 patients (31 DHS, 29 cancellous screws, 2 failed consent). Six deaths (19.3%) were seen in each group. A total of 3.2% of DHS (1 out of 31) and 10.3% (3 out of 29) of cancellous screw patients required re-operation (P = 0.272). There was no statistical significant difference in patient satisfaction, quality of life (QoL), radiological union or osteonecrosis. There are trends towards better functional scores and QoL in cancellous screws, particularly at 1 year (P = 0.0061), but with a higher re-operation rate. There was a combined mortality and transition to institutional care of 40.0% (24 out of 60) at 2 years.

Conclusions
This study found no difference in outcomes between DHS and cancellous screws in the treatment of subcapital NOFFs in a fit, independent population, but we found a high level of physical decline in previously fit, independently ambulating patients. A large, multicentre trial will be required to differentiate between these two fixation methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper investigates axis-symmetric parallel manipulators, composed of a central base column and an arm system able to rotate around this column. The arm system includes several actuated upper arms, each connected to a manipulated platform by one or more lower arm linkages. Such manipulators feature an extensive positional workspace in relation to the manipulator footprint and equal manipulator properties in all radial half-planes defined by the common rotation-axis of the upper arms. The similarities between planar manipulators exclusively employing 2-degrees-of-freedom (2-DOF) lower arm linkages and lower mobility spatial manipulators only utilising 5-DOF lower arm linkages are analysed. The 2-DOF linkages are composed of a link with a 1-DOF hinge on both ends whilst the 5-DOF linkages utilise 3-DOF spherical joints and 2-DOF universal joints. By employing a proposed linkage substitution scheme, it is shown how a wide range of spatial axis-symmetric parallel manipulators can be derived from a limited range of planar manipulators of the same type.