41 resultados para SIMULATOR

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a technique for the real-time modeling of deformable tissue. Specifically geared towards needle insertion simulation, the low computational requirements of the model enable highly accurate haptic feedback to a user without introducing noticeable time delay or buzzing generally associated with haptic surgery simulation. Using a spherical voxel array combined with aspects of computational geometry and agent communication and interaction principals, the model is capable of providing haptic update rates of over 1000Hz with real-time visual feedback. Iterating through over 1000 voxels per millisecond to determine collision and haptic response while making use of Vieta’s Theorem for extraneous force culling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Deakin University’s futuristic Universal Motion simulator will overcome the limitations of current motion simulator platforms by employing an anthropomorphic robot arm to provide the motion fidelity necessary to exploit the potential of modern simulation environments. Full motion simulators frequently utilize Stewart platforms to mimic the movement of vehicles during simulation. However, due to the limited motion range and dexterity of such systems, and their inability to convey realistic accelerations, they are unable to represent accurate motion characteristics. The Universal Motion Simulation aims to close the gap between the limitations of the current motion technology and real world, by introducing a flexible, modular, high-fidelity motion system that can be used for a variety of immersive training applications. The modular nature of the design allows interchangeable and configurable simulation pods to be attached to the end effectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Training of optometrists is traditionally achieved under close supervision of peers and superiors. With the rapid advancement in technology, medical procedures are performed more efficiently and effectively, resulting in faster recovery times and less trauma to the patient. However, application of this technology has made it difficult to effectively demonstrate and teach these manual skills as the education is now a combination of not only the medical procedure but also the use of the technology. In this paper we propose to increase the training capabilities of optometry students through haptically-enabled single-point and multi-point training tools as well as augmented reality techniques. Haptics technology allows a human to touch and feel virtual computer models as though they are real. Through physical connection to the operator, haptic devices are considered to be personal robots that are capable of improving the human-computer interaction with a virtual environment. These devices have played an increasing role in developing expertise, reducing instances of medical error and reducing training costs. A haptically-enabled virtual training environment, integrated with an optometry slit lamp instrument can be used to teach cognitive and manual skills while the system tracks the performance of each individual. These interactions would ideally replicate every aspect of the real procedure, consequently preparing the trainee for every possible scenario, without risking the health of a real patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessment in education is a recent phenomenon. Although there were counterparts in former epochs, the term assessment only began to be spoken about in education after the Second World War; and, since that time, views, strategies and concerns over assessment have proliferated according to an uncomfortable dynamic. We fear that, increasingly, education is assessment-led rather than learning-led and ‘counter to what is desired’ in an ugly judgemental spirit whose moral underpinnings deserve scrutiny. In this article, we seek to historicise assessment and the anxieties of credentialising students. Through this longer history, we present a philosophy of assessment which underlies the development of a new method in assessment-as-learning. We hope that our development of a conversation simulator helps restore the innocence of education as learning-led, while still delivering on the incumbencies of assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are several complications associated with Stent-assisted Coil Embolization (SACE) in cerebral aneurysm treatments, due to damaging operations by surgeons and undesirable mechanical properties of stents. Therefore, it is necessary to develop an in vitro simulator that provides both training and research for evaluating the mechanical properties of stents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A plain carbon steel was deformed using a hot torsion deformation simulator. A schedule known to produce strain-induced ferrite was used with the strain interrupted for increasing intervals of time to determine the effect of an isothermal hold on the final microstructure. Microscopy and electron back-scattered diffraction (EBSD) were used to analyse the changes that occurred in the partially transformed microstructure during the hold and the subsequent applied strain. The strain-induced ferrite coarsened during the hold and this coarsened ferrite was refined during the second deformation. These results were compared to those obtained for a different plain carbon steel deformed in single pass rolling close to the Ar3 temperature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Photocatalytic oxidation (PCO) process is an effective way to deal with organic pollutants in wastewater which could be difficult to be degraded by conventional biological treatment methods. Normally the TiO2 powder in nanometre size range was directly used as photocatalyst for dye degradation in wastewater. However the titanium dioxide powder was arduous to be recovered from the solution after treatment. In this application, a new form of TiO2 (i.e. pillar pellets ranging from 2.5 to 5.3 mm long and with a diameter of 3.7 mm) was used and investigated for photocatalytic degradation of textile dye effluent. A test system was built with a flat plate reactor (FPR) and UV light source (blacklight and solar simulator as light source respectively) for investigating the effectiveness of the new form of TiO2. It was found that the photocatalytic process under this configuration could efficiently remove colours from textile dyeing effluent. Comparing with the TiO2 powder, the pellet was very easy to recovered from the treated solution and can be reused in multiple times without the significant change on the photocatalytic property. The results also showed that to achieve the same photocatalytic performance, the FPR area by pellets was about 91% smaller than required by TiO2 powder. At least TiO2 pellet could be used as an alternative form of photocatalyst in applications for textile effluent treatment process, also other wastewater treatment processes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In stamping operations, the sliding of the sheet metal over the drawbeads is of great importance. The geometry of the drawbead and the degree of penetration both influence material flow and alter the frictional effects between the work and the tool. The effect of drawbead penetration over drawbeads has been studied using the Drawbead Simulator (DBS) test. The contact phenomenon between the sheet and drawbeads was analysed by examining deformed samples with an image fitting technique. The results were compared with an FE simulation and with an approximate geometric analysis. The results give a useful relationship between the rates of change of the contact angle with increasing bead penetration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

While methadone is currently the primary pharmacotherapy used in the treatment of heroin dependence in Australia, levo-alpha-acetyl-methodol (LAAM) and buprenorphine are new pharmacotherapies that are being examined as alternatives to methadone maintenance treatment. The aim of this research is to consider the effects of the methadone, buprenorphine and LAAM, as used in maintenance pharmacotherapy for heroin dependence, upon simulated driving. Clients stabilised in methadone, LAAM and buprenorphine treatment programs for 3 months, and a control group of non-drug-using participants, took part in this study which involved operating a driving simulator over a 75 min period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The medical interpreter's performance can be enhanced if the physician is trained to work effectively with the interpreter. This paper reports on the training of first year medical interns at Southernhealth, a regional network of hospitals in Victoria, Australia. This Commonwealth funded programme was compulsory for all first year doctors. Workshops occurred in the simulator training unit using accident and emergency scenarios. Core teaching material comprised the video and book, Medical Interpreting. Participants were medical interns, qualified telephone medical interpreters, the chief hospital interpreter and the main instructor. Each intern engaged in a simulated role play; observational notes and feedback were recorded. The teaching methodology has demonstrated it to be a programme that skills the physician to work effectively with the medical interpreter. The material and the methodology can be used by interpreters and medical communication specialists to train medical practitioners.