7 resultados para Rectifying circuits

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Losing information causes losing power. Information is lost when the input vector cannot be uniquely recovered from the output vector of a combinational circuit. The input vector of reversible circuit can be uniquely recovered from the output vector. In this study we have emphasized on the design of reversible adder circuits that is efficient in terms of gate count, garbage outputs and quantum cost and that can be technologically mapped. It has been analyzed and demonstrated that the results of our proposed adder circuits shows better performance compared to similar type of existing designs. Technology independent equations required to evaluate these circuits have also been given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Randomly oriented tin oxide (SnO2) nanofibers and poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate)/polyvinylpyrrolidone (PEDOT:PSS/PVP) nanofibers were prepared by a two-step electrospinning technique to form a layered fibrous mat. The current-voltagemeasurement revealed that the fibrousmat had an obvious diode-rectifying characteristic. The thickness of the nanofiber layers was found to have a considerable influence on the device resistance and rectifying performance. Such an interesting rectifying property was attributed to the formation of a ??-?? junction between the fibrous SnO2 and PEDOT:PSS/PVP layers. This is the first report that a rectifying junction can be formed between two layers of electrospun nanofiber mats, and the resulting nanofibrous diode rectifier may find applications in sensors, energy harvest, and electronic textiles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the presence of single-use airway filters, we quantified anaesthetic circuit aerobic microbial contamination rates when changed every 24 h, 48 h and 7 days. Microbiological samples were taken from the interior of 305 anaesthetic breathing circuits over a 15-month period (3197 operations). There was no significant difference in the proportion of contaminated circuits when changed every 24 h (57/105 (54%, 95% CI 45–64%)) compared with 48 h (43/100 (43%, 95% CI 33–53%, p = 0.12)) and up to 7 days (46/100 (46%, 95% CI 36–56%, p = 0.26)). Median bacterial counts were not increased at 48 h or 7 days provided circuits were routinely emptied of condensate. Annual savings for one hospital (six operating theatres) were $AU 5219 (£3079, €3654, $US 4846) and a 57% decrease in anaesthesia circuit steriliser loads associated with a yearly saving of 2760 kWh of electricity and 48 000 l of water. Our findings suggest that extended circuit use from 24 h up to 7 days does not significantly increase bacterial contamination, and is associated with labour, energy, water and financial savings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

 Development of an optimum rectenna for radio frequency energy harvesting in miniature head-mountable deep brain stimulation (DBS) devices. The designed miniature rectenna can operate a DBS device without battery for murine preclinical research. The battery-less operation of the device eliminates battery related difficulties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses design and fabrication processes in the development of a wearable and flexible conductive resistive sensor. The design and development of the sensor involve the use of Sn-Ag-Cu (SAC)plated Nylon fabric, precisionfused deposition modeling(FDM) using silicone and petrolatum for etch-resistant masks using the EnvisionTEC GmbH Bioplotter, and wet etching using Chromium, Ammonium Persulphate, and Salt-Vinegar etching solutions. Preliminary testing with other mask types, development processes, and sensor design approaches for various applications are discussed.