14 resultados para RELATIVE-HUMIDITY

em Deakin Research Online - Australia


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Environmental factors may affect chemical communication between individuals by limiting their ability to detect and respond to these signals. One such factor, high humidity, has been shown to interfere with the normal response of some invertebrate species to their attractant pheromones. The effect of humidity on the response of the five-spined bark beetle, Ips grandicollis, to a synthetic form of the aggregation pheromone component ipsenol, was tested in an experimental chamber in the laboratory. The response was measured as both the number of beetles to reach the pheromone source and the time taken, and was tested under high (>80% relative humidity) and low (30–40% relative humidity) conditions of humidity. There was no significant difference in response of beetles between the two treatments although there was a reduction in response in the high-humidity treatment when relative humidity levels were in excess of 90%. These findings suggest that atmospheric humidity does not influence bark beetles response to synthetic pheromone, except perhaps in unlikely conditions of excessive humidity.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A novel sensitive humidity nanosensor based on Na1-doped ZnO nanofiber membrane has been prepared via electrospinning and calcination. The product was characterized by scanning electron microscopy and X-ray diffraction. During the whole relative humidity (11%–95%) measurement, the response and recovery time is about 3 and 6 s, respectively, with good linearity, and reproducibility. These remarkable and sensitive sensing performances make our product a good candidate in fabricating humidity sensors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Six endurance-trained men [peak oxygen uptake (VO2) = 4.58 ± 0.50 (SE) l/min] completed 60 min of exercise at a workload requiring 68 ± 2% peak VO2 in an environmental chamber maintained at 35°C (<50% relative humidity) on two occasions, separated by at least 1 wk. Subjects ingested either a 6% glucose solution containing 1 µCi [3-3H]glucose/g glucose (CHO trial) or a sweet placebo (Con trial) during the trials. Rates of hepatic glucose production [HGP = glucose rate of appearance (Ra) in Con trial] and glucose disappearance (Rd), were measured using a primed, continuous infusion of [6,6-2H]glucose, corrected for gut-derived glucose (gut Ra) in the CHO trial. No differences in heart rate, VO2, respiratory exchange ratio, or rectal temperature were observed between trials. Plasma glucose concentrations were similar at rest but increased (P < 0.05) to a greater extent in the CHO trial compared with the Con trial. This was due to the absorption of ingested glucose in the CHO trial, because gut Ra after 30 and 50 min (16 ± 5 µmol · kg-1 · min-1) was higher (P < 0.05) compared with rest, whereas HGP during exercise was not different between trials. Glucose Rd was higher (P < 0.05) in the CHO trial after 30 and 50 min (48.0 ± 6.3 vs 34.6 ± 3.8 µmol · kg-1 · min-1, CHO vs. Con, respectively). These results indicate that ingestion of carbohydrate, at a rate of ~1.0 g/min, increases glucose Rd but does not blunt the rise in HGP during exercise in the heat.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The thermoregulatory responses of subjects wearing two different forms of rugby league jersey, one with plastic sponsorship recognition and numbering (trial Gl) and one without (trial G2), and a lightweight alternative (trial G3), were compared with a trial without any form of upper body garment (trial GO). Ten male volunteers, mean age 20.9 (±2.3) years, height 179.8 (±4.7) cm, weight 80.2 (±8.9) kg, and body surface area 1.99 (±0.13) m2, participated in this study. Subjects had a mean maximal oxygen uptake capacity of 56.0 (±6.3) ml.kg.min-1 and a sum of 8 skinfolds of 80.6 (±23.8) mm. Subjects were exercised at approximately 50% of maximal oxygen uptake in a warm humid environment for 50 minutes. Mean ambient temperature was 27.6°C (±0.32) with a relative humidity of 64.7% (±1.44). Measurements of core and skin (7 sites) temperature, heart rate, oxygen uptake, plasma volume, peak lactate concentration, and pre- and post-trial body weight, hematocrit and garment weight were recorded. The statistical results showed that all subjects experienced significant (p ≤.0001) decreases in body weight representing a percentage decrease ranging from 1.2-1.3%. No significant difference was found between trials with respect to body weight change. No significant effect of garment type was found on pre- and post-trial hematocrit, plasma volume changes or peak blood lactic acid concentration. However, mean peak lactate was highest for trial Gl (5.6 mmol.L-1 ±2.2) and lowest for trial G3 (4.6 mmol.L-1 ±1.27). Post-trial core temperature was significantly (p≤ .0001) higher than the resting value; no significant difference was found between trials. The mean absolute increase for all experimental trials was 0.9°C. A significant (p≤.005) difference between mean total (7 sites) skin temperature was found with a post-hoc test revealing that trials Gl and G2 were significantly higher than trial GO; no significant difference was found when comparing trial G3 with trial GO or when comparing the garments between each other. Mean skin temperature under the garment (4 sites) was found to be significantly (p≤.05) higher for all trials involving a garment when compared with mean skin temperature outside (3 sites) the garment; no significant difference was found between trials. Mean oxygen uptake was significantly different between trials (p≤.005), with trial Gl and G3 found to be significantly lower than trial GO; no difference was found when comparing the garments with each other. Post-trial garment weights were significantly (p≤.001) heavier than pre-trial and were significantly (p≤.0001) different when compared with each other. There was no significant effect on heart rate, haematocrit, plasma volume changes, peak blood lactic acid concentration, or core temperature due to garment type. However, differences in skin temperature suggest that the garment used in trial G3 may have a benefit. Further research should consider the impact of increased exercise intensity and/or environmental temperature and humidity on the measured parameters while wearing the garments described in this study.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The production of alumina involves the use of a process known as the Bayer process. This method involves the digestion of raw bauxite in sodium hydroxide at temperatures around 250°C. The resultant pregnant liquor then goes through a number of filtering and precipitation processes to obtain the aluminium oxide crystals which are then calcined to obtain the final product. The plant is situated in a sub tropical climate in Northern Australia and this combined with the hot nature of the process results in a potential for heat related illnesses to develop. When assessing a work environment for heat stress a heat stress index is often employed as a guideline and to date the Wet Bulb Globe Temperature (WBGT) has been the recommended index. There have been concerns over the past that the WBGT is not suited to the Northern Australian climate and in fact studies in other countries have suggested this is the case. This study was undertaken in the alumina plant situated in Gladstone Queensland to assess if WBGT was in fact the most suitable index for use or if another was more applicable. To this end three indices, Wet Bulb Globe Temperature (WBGT), Heat Stress Index (HSI) and Required Sweat Rate (SWreq) were compared and assessed using physiological monitoring of heart rate and surrogate core temperature. A number of different jobs and locations around the plant were investigated utilising personal and environmental monitoring equipment. These results were then collated and analysed using a computer program written as part of the study for the manipulation of the environmental data . Physiological assessment was carried out using methods approved by international bodies such as National Institute for Occupational Safety & Health (NIOSH) and International Standards Organisation (ISO) and incorporated the use of a ‘Physiological Factor’ developed to enable the comparison of predicted allowable exposure times and strain on the individual. Results indicated that of the three indices tested, Required Sweat Rate was found to be the most suitable for the climate and in the environment of interest. The WBGT system was suitable in areas in the moderate temperature range (ie 28 to 32°C) but had some deficiencies above this temperature or where the relative humidity exceeded approximately 80%. It was however suitable as a first estimate or first line indicator. HSI over-estimated the physiological strain in situations of high temperatures, low air flows and exaggerated the benefit of artificial air flows on the worker in certain environments ie. fans.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper centres around the presentation of multiple measured results on a psychrometric chart. The psychrometric chart was programmed in Microsoft Office Excel to accommodate measured results. It was written because existing programs appear not to cater for the researcher wishing to enter results electronically onto the chart. Furthermore, many existing charts are complex and cluttered displaying up to ten attributes, being intended for engineering design, whereas presenting the behaviour of living and working environments is focused on wet and dry bulb temperature and relative humidity. As well as results, users would also like to specify and adjust the ‘comfort zone’ (a shaded area on the chart) for different ‘adaptive’ or ‘seasonal’ conditions. The comfort zone is bounded by lines of constant heat loss from the skin, relative humidity and wet-bulb temperature. The paper presents various applications of the psychrometric chart for the analysis and reporting of research and discusses the programming of Microsoft Office Excel to generate the chart and display user data.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Exposure to airborne pollen from certain plants can cause allergic disease, leading to acute respiratory symptoms. Whole pollen grains, 15–90 μ m-sized particles, provoke the upper respiratory symptoms of rhinitis (hay fever), while smaller pollen fragments capable of depositing in the lower respiratory tract have been proposed as the trigger for asthma. In order to understand factors leading to pollen release and fragmentation we have examined the rupture of Chinese elm pollen under controlled laboratory conditions and in the outdoor atmosphere. Within 30 minutes after immersion in water, 70% of fresh Chinese pollen ruptures, rapidly expelling cytoplasm. Chinese elm flowers, placed in a controlled atmosphere chamber, emitted pollen and pollen debris after a sequential treatment of 98% relative humidity followed by drying and a gentle disturbance. Immunologic assays of antigenic proteins specific to elm pollens revealed that fine particulate material (D p < 2 μ m) collected from the chamber contained elm pollen antigens. In a temporal study of the outdoor urban atmosphere during the Chinese elm bloom season of 2004, peak concentrations of pollen and fine pollen fragments occurred at the beginning of the season when nocturnal relative humidity (RH) exceeded 90%. Following later periods of hot dry weather, pollen counts decreased to zero. The Chinese elm pollen fragments also decreased during the hot weather, but later displayed additional peaks following periods of more moderate RH and temperature, indicating that pollen counts underestimate total atmospheric pollen allergen concentrations. Pollen fragments thus increase the biogenic load in the atmosphere in a form that is no longer recognizable as pollen and, therefore, is not amenable to microscopic analysis. This raises the possibility of exposure of sensitive individuals to pollen allergens in the form of fine particles that can penetrate into the lower airways and pose potentially severe health risks.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

[1] As part of the Large-Scale Biosphere-Atmosphere Experiment in Amazonia (LBA)-Cooperative LBA Airborne Regional Experiment (CLAIRE) 2001 campaign in July 2001, separate day and nighttime aerosol samples were collected at a ground-based site in Amazonia, Brazil, in order to examine the composition and temporal variability of the natural “background” aerosol. We used a high-volume sampler to separate the aerosol into fine (aerodynamic diameter, AD < 2.5 μm) and coarse (AD > 2.5 μm) size fractions and quantified a range of organic compounds in methanolic extracts of the samples by a gas chromatographic-mass spectrometric technique. The carbon fraction of the compounds could account for an average of 7% of the organic carbon (OC) in both the fine and coarse aerosol fractions. We observed the highest concentrations of sugars, sugar alcohols, and fatty acids in the coarse aerosol samples, which suggests that these compounds are associated with primary biological aerosol particles (PBAP) observed in the forest atmosphere. Of these, trehalose, mannitol, arabitol, and the fatty acids were found to be more prevalent at night, coinciding with a nocturnal increase in PBAP in the 2–10 μm size range (predominantly yeasts and other small fungal spores). In contrast, glucose, fructose, and sucrose showed persistently higher daytime concentrations, coinciding with a daytime increase in large fungal spores, fern spores, pollen grains, and, to a lesser extent, plant fragments (generally >20 μm in diameter), probably driven by lowered relative humidity and enhanced wind speeds/convective activity during the day. For the fine aerosol samples a series of dicarboxylic and hydroxyacids were detected with persistently higher daytime concentrations, suggesting that photochemical production of a secondary organic aerosol from biogenic volatile organic compounds may have made a significant contribution to the fine aerosol. Anhydrosugars (levoglucosan, mannosan, galactosan), which are specific tracers for biomass burning, were detected only at low levels in the fine aerosol samples. On the basis of the levoglucosan-to-OC emission ratio measured for biomass burning aerosol, we estimate that an average of ∼16% of the OC in the fine aerosol was due to biomass burning during CLAIRE 2001, indicating that the major fraction was associated with biogenic particles.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, the effect of various aging environments on the painted surface finish of unidirectional carbon fibre composite laminates, manufactured by autoclave and a novel out-of-autoclave technique was investigated. Laminates were exposed to water immersion, 95 % relative humidity and cyclic environments for 552 h and the surface finish was evaluated using visual and wave-scan distinctness of image (DOI) techniques. It was found that the laminate surface finish was dependent on the amount of moisture in the aging test. Minor surface waviness occurred on the laminates exposed to the cyclic test, whereas, surface waviness, print through and DOI values were all significantly higher as the laminates absorbed larger quantities of moisture from the hygrothermal and hydrothermal tests. The water immersion test, which was the most detrimental to the surface finish of the painted laminates, produced dense blistering on the autoclave manufactured laminate surface whereas the out-of-autoclave laminate surface produced only a few. It was found that the out-of-autoclave laminate had high substrate surface roughness which resulted in improved paint adhesion and, therefore, prevented the formation of surface blistering with aging. © 2012 Springer Science+Business Media Dordrecht.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of the present study was to determine if there is an acclimation effect when unacclimatized males exercise in the heat at weekly intervals. Five subjects performed four exercise bouts, each lasting 1 h at 55% VO2max. The first trial was in moderate conditions (mean(s.d.) temperature (Ta) = 22.0(0.8)degrees C; mean(s.d.) relative humidity (rh) = 67(6)%) and the subsequent three trials were carried out at weekly intervals in the heat (mean(s.d.) Ta = 34.6(0.6)degrees C; mean(s.d.) rh = 60(7)%). There were no significant differences between trials in the heat for heart rate, rectal temperature, skin temperature or VO2 (repeated measures analysis of variance), and total sweat loss (one-way analysis of variance). As changes in these variables are seen with heat acclimation it was concluded that there was no heat acclimation effect and separating exercise bouts by 1 week was a valid method for comparing the effects of different treatments on unacclimatized males during exercise in the heat.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Transformerless inverters technology in photovoltaic systems offers many advantages, but there are some safety issues due to the solar panel parasitic capacitance. The parasitic capacitance value depends on many factors such as PV panels and frame structure, surface of the cells, distance between the cells, module frame, weather conditions (e.g., humidity) and the amount of dust covering the PV panel. Harsh climate like the one in the Central Queensland region is characterized by high temperature, high relative humidity. Due to the region’s high dew point, high humidity and heavy rain during the wet season, the water condensed over the PV array surface will affect the stray capacitance significantly and consequently, the system leakage current. Human safety in PV system is a key issue, which must be addressed when this technology is applied. Protection against electrical shock is essential while deploying such systems to avoid injury or loss of life. Furthermore, PV insulation varies with meteorological conditions such as, temperatures, humidity. Therefore, the protective circuit should have the capability to adapt to any changes in metrological variables. This paper explorers the effect of meteorological changes on the insulation parameters and leakage capacitance and design a tools for protection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The resurrection grass Sporobolus stapfianus Gandoger can rapidly recover from extended periods of time in the desiccated state (water potential equilibrated to 2% relative humidity) (Gaff and Ellis, Bothalia 11:305–308 1974; Gaff and Loveys, Transactions of the Malaysian Society of Plant Physiology 3:286–287 1993). Physiological studies have been conducted in S. stapfianus to investigate the responses utilised by these desiccation-tolerant plants to cope with severe water-deficit. In a number of instances, more recent gene expression analyses in S. stapfianus have shed light on the molecular and cellular mechanisms mediating these responses. S. stapfianus is a versatile research tool for investigating desiccation-tolerance in vegetative grass tissue, with several useful characteristics for differentiating desiccation-tolerance adaptive genes from the many dehydration-responsive genes present in plants. A number of genes orthologous to those isolated from dehydrating S. stapfianus have been successfully used to enhance drought and salt tolerance in model plants as well as important crop species. In addition to the ability to desiccate and rehydrate successfully, the survival of resurrection plants in regions experiencing short sporadic rainfall events may depend substantially on the ability to tightly down-regulate cell division and cell wall loosening activities with decreasing water availability and then grow rapidly after rainfall while water is plentiful. Hence, an analysis of gene transcripts present in the desiccated tissue of resurrection plants may reveal important growth-related genes. Recent findings support the proposition that, as well as being a versatile model for devising strategies for protecting plants from water-loss, resurrection plants may be a very useful tool for pinpointing genes to target for enhancing growth rate and biomass production.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Passive cooling system has become an attractive option to design and modify homes to achieve thermal comfort. The system provides cooling through the use of passive processes, which often use heat flow paths that do not exist in conventional or bioclimatic buildings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The flight range of migrating birds depends crucially on the amount of fuel stored by the bird prior to migration or taken up en route at stop-over sites. However, an increase in body mass is associated with an increase in energetic costs, counteracting the benefit of fuel stores. Water imbalance, occurring when water loss exceeds metabolic water production, may constitute another less well recognised problem limiting flight range. The main route of water loss during flight is via the lungs; the rate of loss depends on ambient temperature, relative humidity and ventilatory flow and increases with altitude. Metabolite production results in an increased plasma osmolality, also endangering the proper functioning of the organism during flight. Energetic constraints and water-balance problems may interact in determining several aspects of flight behaviour, such as altitude of flight, mode of flight, lap distance and stop-over duration. To circumvent energetic and water-balance problems, a bird could migrate in short hops instead of long leaps if crossing of large ecological barriers can be avoided. However, although necessitating larger fuel stores and being more expensive, migration by long leaps may sometimes be faster than by short hops. Time constraints are also an important factor in explaining why soaring, which conserves energy and water, occurs exclusively in very large species: small birds can soar at low speeds only. Good navigational skills involving accurate orientation and assessment of altitude and air and ground speed assist in avoiding physiological stress during migration.