3 resultados para Pulsed Photoacoustic Technique

em Deakin Research Online - Australia


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Some people who experience migraine demonstrate reduced visual contrast sensitivity that is measurable between migraines. Contrast sensitivity loss to low spatial frequency gratings has been previously attributed to possible impairment of magnocellular pathway function. This study measured contrast sensitivity using low spatial frequency targets (0.25–4 c/deg) where the adaptation aspects of the stimuli were designed to preferentially assess either magnocellular or parvocellular pathway function (steady and pulsed pedestal technique). Twelve people with migraine with measured visual field abnormalities and 17 controls participated. Subjects were tested foveally and at 10° eccentricity. Foveally, there was no significant difference in group mean contrast sensitivity. At 10°, the migraine group demonstrated reduced contrast sensitivity for both the stimuli designed to assess magnocellular and parvocellular function (P < 0.05). The functional deficits measured in this study infer that abnormalities of the low spatial frequency sensitive channels of both pathways contribute to contrast sensitivity deficits in people with migraine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have developed a rapid and robust method for the determination of urea in spent haemodialysis fluid as a measure of the efficiency of haemodialysis treatments. A novel flow analysis instrument (which generates a pulsed solution flow) was coupled with a chemiluminescence detection system, based on the oxidation of urea with hypobromite. The ‘pulsed-flow chemiluminescence analyser’ exhibited high precision (1.6% relative standard deviation (R.S.D.) for a 1×10−5 M urea standard, n=10) and good limit of detection (9×10−7 M, S/N=3) as a result of the rapid and reproducible mixing of small volumes of reagent and sample at the point of detection. The proposed chemiluminescence technique and an established urease-based laboratory procedure were compared, and showed a very similar trend for the change in urea concentration during a typical haemodialysis treatment. The relative chemiluminescence response from the oxidation of species with similar structure has revealed the inherent selectivity of the light producing pathway, but a positive interference was obtained from protein when this technique was applied to the determination of urea in serum samples. Arginine was identified as the predominant source of this interference.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Liquid plasma, produced by nanosecond pulses, provides an efficient and simple way to fabricate a nanocomposite architecture of Co3O4/CNTs from carbon nanotubes (CNTs) and clusters of Co3O4 nanoparticles in deionized water. The crucial feature of the composite's structure is that Co3O4 nanoparticle clusters are uniformly dispersed and anchored to CNT networks in which Co3O4 guarantees high electrochemical reactivity towards sodium, and CNTs provide conductivity and stabilize the anode structure. We demonstrated that the Co3O4/CNT nanocomposite is capable of delivering a stable and high capacity of 403 mA h g(-1) at 50 mA g(-1) after 100 cycles where the sodium uptake/extract is confirmed in the way of reversible conversion reaction by adopting ex situ techniques. The rate capability of the composite is significantly improved and its reversible capacity is measured to be 212 mA h g(-1) at 1.6 A g(-1) and 190 mA h g(-1) at 3.2 A g(-1), respectively. Due to the simple synthesis technique with high electrochemical performance, Co3O4/CNT nanocomposites have great potential as anode materials for sodium-ion batteries.