14 resultados para Printed Monopole Antenna

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is about challenges to the hegemony of printed books in Australian tertiary education and the potential demise of that hegemony. Not because the book in its traditional form is considered by some to be outdated and not because ofcompeting products that might put the use of the traditional book under threat - our Australian 'book-industry' might well rise to such challenges given that competitiveness is a driving feature of business. This paper is about challenges to the hegemony of printed books in tertiary education because of forces entirely outside the 'book-industry's' control.

The function of traditional printed books within tertiary education is changing. Education is a user-pays product, and competitive pressures ensure students are given greater voice in the types of learning resources provided, with the evolution of electronic and communication technologies allowing student learning resources to be made available in a myriad of ways. Thus a traditional printed book may be an inflexible tool in a dynamic environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the problem of the design of a precoder for multiple transmit antenna communication systems with spatially and temporally correlated fading channels. Using the theories of matrix differential calculus, the paper derives a precoder for unitary space-time codes that can exploit the spatio-temporal correlation in the time-varying fading channels. The design criterion is based on minimizing the mean square error of the channel estimates. Computer simulation results show that a significant performance gain can be achieved by using the designed precoder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Differential space-time modulation (DSTM) techniques developed for multi-antenna systems allow the receiver to detect the transmitted signal without the knowledge of the fading channels. It can be viewed as an extension of differential phase-shift keying (DPSK) in single antenna systems. In this paper, we derived the pairwise error probability upper bound of differential space-time coded systems with spatially correlated Rayleigh fading channels. Based on the performance analysis, we develop a novel DSTM scheme which can exploit the spatial correlation in the fading channels. It is found that by carefully designing the initial transmitted signal matrix, the performance of the differential space-time coded systems can be significantly improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research addressed performance issues for wireless signal transmission and has shown that performance improves with the help of relays due to increased diversity. Further, the areas of antenna selection and channel estimation and modelling has been investigated for improved cost and complexity and has shown to further enhance the performance of the wireless relay systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A compact meandered three-layer stacked circular planar inverted-F antenna is designed and simulated at the UHF band (902.75 – 927.25 MHz) for passive deep brain stimulation implants. The UHF band is used because it offers small antenna size, and high data rate. The top and middle radiating layers are meandered, and low cost substrate and superstrate materials are used to limit the radius and height of the antenna to 5 mm and 1.64 mm, respectively. A dielectric substrate of FR-4 of εr= 4.7 and δ= 0.018, and a biocompatible superstrate of silicone of er= 3.7 and d= 0.003 with thickness of 0.2 mm are used in the design. The resonance frequency of the proposed antenna is 918 MHz with a bandwidth of 24 MHz at return loss of −10 dB in free space. The antenna parameter such as 3D gain pattern of the designed antenna within a skin-tissue model is evaluated by using the finite element method. The compactness, wide bandwidth, round shape, and stable characteristics in skin make this antenna suitable for DBS. The feasibility of the wireless power transmission to the implant in the human head is also examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multi-layer circular planar inverted-F antenna is designed and simulated at the industrial, scientific, and medical (ISM) band of 915 MHz for closed loop deep brain stimulation implant. The ISM band is considered due to the capabilities of small antenna size, high data rate, and long transmission range. In the proposed four-layer antenna, the top three radiating layers are meandered, and a high permittivity substrate and superstrate materials are used to limit the radius and the height of the antenna to 3.5 mm and 2.2 mm, respectively. The bottom layer works as a ground plate. The Roger RO3210 of εr = 10.2 and δ = 0.003 is used as a dielectric substrate and superstrate. The resonance frequency of the proposed antenna is 915 MHz with a bandwidth of 12 MHz at the return loss of -10 dB in free space. The stacked layered structure reduces the antenna size, and the circular shape makes it easily implantable into the human head. The antenna parameters (e.g. 3D gain pattern), SAR value, and electric field distribution within a six layers spherical head model are evaluated by using the finite element method (FEM). The feasibility of the wireless transmission of power, control and command signal to the implant in the human head is also examined. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents design and simulation of a circular meander dipole antenna at the industrial, scientific, and medical band of 915 MHz for energy scavenging in a passive head-mountable deep brain stimulation device. The interaction of the proposed antenna with a rat body is modeled and discussed. In the antenna, the radiating layer is meandered, and a FR-4 substrate is used to limit the radius and height of the antenna to 14 mm and 1.60 mm, respectively. The resonance frequency of the designed antenna is 915 MHz and the bandwidth of 15 MHz at a return loss of -10 dB in free space. To model the interaction of the antenna with a rat body, two aspects including functional and biological are considered. The functional aspect includes input impedance, resonance frequency, gain pattern, radiation efficiency of the antenna, and the biological aspect involves electric field distribution, and SAR value. A complete rat model is used in the finite difference time domain based EM simulation software XFdtd. The simulated results demonstrate that the specific absorption rate distributions occur within the skull in the rat model, and their values are higher than the standard regulated values for the antenna receiving power of 1W.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study is to design a low-cost planar Archimedean dipole antenna for batteryless transcranial direct current stimulation devices. The antenna parameters including resonance frequency, radiation efficiency, radiation pattern, and gain are simulated using finite difference time domain based electromagnetic simulation software XFdtd. The proposed antenna is simulated with low-cost FR4 PCB substrate of thickness of 1.6 mm. The antenna is designed with half wavelength of resonant frequency and fed with a matching line. The target frequency band is the industrial, scientific and medical (ISM) band of 915 MHz which is in the simulated band width of 31 MHz (903-934MHz). Moreover, since the bio-effect of specific absorption rate by radio frequency electromagnetic wave for power harvesting is an important concern, we try to find out the safety limit. Thus a quantitative analysis of distributions of electric field and power absorption in anatomical human head model by the far field radio frequency energy received by our designed antenna has been presented.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herein we explore modern fabrication techniques for the development of chemiluminescence detection flow-cells with features not attainable using the traditional coiled tubing approach. This includes the first 3D-printed chemiluminescence flow-cells, and a milled flow-cell designed to split the analyte stream into two separate detection zones within the same polymer chip. The flow-cells are compared to conventional detection systems using flow injection analysis (FIA) and high performance liquid chromatography (HPLC), with the fast chemiluminescence reactions of an acidic potassium permanganate reagent with morphine and a series of adrenergic phenolic amines.