15 resultados para Power device

em Deakin Research Online - Australia


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This OXADM are located in the nodes, which have more than two switching directions in ring networks. The function of OXADM is to flexibility switch the wavelengths among the different input and output ports. Because of the OXADM's imperfect performance, the insertion loss and crosstalk are induced in the system. Analytical modeling method is using to analyze the OXADM structure in crosstalk or power leakage that lead to the power penalty. To overcome this problem, power penalty is needed to be supplied. The insertion of this power penalty depends on few parameters. The parameters that we going to investigate here will be in term of number of operating wavelengths and number of input/output ports as well as the Q factor. The variation of this parameters will affects the amount of the desired power penalty. Simulation results in higher crosstalk or higher power penalty needed as the number of OXADM increases. As the sum of the wavelength and the number of input/output for each OXADM increases, the power penalty will increased as well. Investigation on the maximum Q factors is 6 to get the minimum power penalty at the lowest BER for most of the combination of the sum of the wavelength and the number of input/output for each OXADM.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Deep brain stimulation has emerged as an effective medical procedure that has therapeutic efficacy in a number of neuropsychiatric disorders. Preclinical research involving laboratory animals is being conducted to study the principles, mechanisms, and therapeutic effects of deep brain stimulation. A bottleneck is, however, the lack of deep brain stimulation devices that enable long term brain stimulation in freely moving laboratory animals. Most of the existing devices employ complex circuitry, and are thus bulky. These devices are usually connected to the electrode that is implanted into the animal brain using long fixed wires. In long term behavioral trials, however, laboratory animals often need to continuously receive brain stimulation for days without interruption, which is difficult with existing technology. This paper presents a low power and lightweight portable microdeep brain stimulation device for laboratory animals. Three different configurations of the device are presented as follows: 1) single piece head mountable; 2) single piece back mountable; and 3) two piece back mountable. The device can be easily carried by the animal during the course of a clinical trial, and that it can produce non-stop stimulation current pulses of desired characteristics for over 12 days on a single battery. It employs passive charge balancing to minimize undesirable effects on the target tissue. The results of bench, in-vitro, and in-vivo tests to evaluate the performance of the device are presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A passive deep brain stimulation (DBS) device can be equipped with a rectenna, consisting of an antenna and a rectifier, to harvest energy from electromagnetic fields for its operation. This paper presents optimization of radio frequency rectifier circuits for wireless energy harvesting in a passive head-mountable DBS device. The aim is to achieve a compact size, high conversion efficiency, and high output voltage rectifier. Four different rectifiers based on the Delon doubler, Greinacher voltage tripler, Delon voltage quadrupler, and 2-stage charge pumped architectures are designed, simulated, fabricated, and evaluated. The design and simulation are conducted using Agilent Genesys at operating frequency of 915 MHz. A dielectric substrate of FR-4 with thickness of 1.6 mm, and surface mount devices (SMD) components are used to fabricate the designed rectifiers. The performance of the fabricated rectifiers is evaluated using a 915 MHz radio frequency (RF) energy source. The maximum measured conversion efficiency of the Delon doubler, Greinacher tripler, Delon quadrupler, and 2-stage charge pumped rectifiers are 78, 75, 73, and 76 % at -5 dBm input power and for load resistances of 5-15 kΩ. The conversion efficiency of the rectifiers decreases significantly with the increase in the input power level. The Delon doubler rectifier provides the highest efficiency at both -5 and 5 dBm input power levels, whereas the Delon quadrupler rectifier gives the lowest efficiency for the same inputs. By considering both efficiency and DC output voltage, the charge pump rectifier outperforms the other three rectifiers. Accordingly, the optimised 2-stage charge pumped rectifier is used together with an antenna to harvest energy in our DBS device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The field of electronic noses and gas sensing has been developing rapidly since the introduction of the silicon based sensors. There are numerous systems that can detect and indicate the level of a specific gas. We introduce here a system that is low power, small and cheap enough to be used in mobile robotic platforms while still being accurate and reliable enough for confident use. The design is based around a small circuit board mounted in a plastic case with holes to allow the sensors to protrude through the top and allow the natural flow of gas evenly across them. The main control board consists of a microcontroller PCB with surface mount components for low cost and power consumption. The firmware of the device is based on an algorithm that uses an Artificial Neural Network (ANN) which receives input from an array of gas sensors. The various sensors feeding the ANN allow the microcontroller to determine the gas type and quantity. The Testing of the device involves the training of the ANN with a number of different target gases to determine the weightings for the ANN. Accuracy and reliability of the ANN is validated through testing in a specific gas filled environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The thesis disturbs the seeming secure foundations of the dominant realist tales about the imperatives for the development of Health Impact Assessment, a relatively new policy device used within governments to consider the effects of policies on health. Foucauldian genealogical approaches are used to provide alternative, non-linear and non-definitive accounts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Randomly orientated electrospun poly(vinylidene fluoride) nanofiber membranes were directly used as active layers to make mechanical-to-electrical energy conversion devices. Without any extra poling treatment, the device can generate high electrical outputs upon receiving a mechanical impact. The device also showed long-term working stability and ability to drive electronic devices. Such a nanofiber membrane device may serve as a simple but efficient energy source for self-powered electronics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents design and simulation of a circular meander dipole antenna at the industrial, scientific, and medical band of 915 MHz for energy scavenging in a passive head-mountable deep brain stimulation device. The interaction of the proposed antenna with a rat body is modeled and discussed. In the antenna, the radiating layer is meandered, and a FR-4 substrate is used to limit the radius and height of the antenna to 14 mm and 1.60 mm, respectively. The resonance frequency of the designed antenna is 915 MHz and the bandwidth of 15 MHz at a return loss of -10 dB in free space. To model the interaction of the antenna with a rat body, two aspects including functional and biological are considered. The functional aspect includes input impedance, resonance frequency, gain pattern, radiation efficiency of the antenna, and the biological aspect involves electric field distribution, and SAR value. A complete rat model is used in the finite difference time domain based EM simulation software XFdtd. The simulated results demonstrate that the specific absorption rate distributions occur within the skull in the rat model, and their values are higher than the standard regulated values for the antenna receiving power of 1W.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Design of a rectangular spiral planar inverted-F antenna (PIFA) at 915 MHz for wireless power transmission applications is proposed. The antenna and rectifying circuitry form a rectenna, which can produce dc power from a distant radio frequency energy transmitter. The generated dc power is used to operate a low-power deep brain stimulation pulse generator. The proposed antenna has the dimensions of 10 mm × 12.5 mm × 1.5 mm and resonance frequency of 915 MHz with a measured bandwidth of 15 MHz at return loss of -10 dB. A dielectric substrate of FR-4 of εr = 4.8 and δ = 0.015 with thickness of 1.5 mm is used for both antenna and rectifier circuit simulation and fabrication because of its availability and low cost. An L-section impedance matching circuit is used between the PIFA and voltage doubler rectifier. The impedance matching circuit also works as a low-pass filter for elimination of higher order harmonics. Maximum dc voltage at the rectenna output is 7.5 V in free space and this rectenna can drive a deep brain stimulation pulse generator at a distance of 30 cm from a radio frequency energy transmitter, which transmits power of 26.77 dBm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Herein, we demonstrate that a flexible, air-permeable, thermoelectric (TE) power generator can be prepared by applying a TE polymer (e.g. poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate)) coated commercial fabric and subsequently by linking the coated strips with a conductive connection (e.g. using fine metal wires). The poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) coated fabric shows very stable TE properties from 300 K to 390 K. The fabric device can generate a TE voltage output (V) of 4.3 mV at a temperature difference (ΔT) of 75.2 K. The potential for using fabric TE devices to harvest body temperature energy has been discussed. Fabric-based TE devices may be useful for the development of new power generating clothing and self-powered wearable electronics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the development of an energy harvesting circuit for use with a head-mountable deep brain stimulation (DBS) device. It consists of a circular planar inverted-F antenna (PIFA) and a Schottky diode-based Cockcroft-Walton 4-voltage rectifier. The PIFA has the volume of π × 10(2) × 1.5 mm(3), resonance frequency of 915 MHz, and bandwidth of 16 MHz (909-925 MHz) at a return loss of -10 dB. The rectifier offers maximum efficiency of 78% for the input power of -5 dBm at a 5 kΩ load resistance. The developed rectenna operates efficiently at 915 MHz for the input power within -15 dBm to +5 dBm. For operating a DBS device, the DC voltage of 2 V is recorded from the rectenna terminal at a distance of 55 cm away from a 26.77 dBm transmitter in free space. An in-vitro test of the DBS device is presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents design, implementation, and evaluation of a miniature rectenna for energy harvesting applications. The rectenna produces DC power from a distant microwave energy transmitter. The generated DC power is then utilized to operate a head-mountable deep brain stimulation device. The rectenna consists of a miniature three-layer planar inverted-F antenna and a Schottky-diode-based bridge rectifier. The antenna has a volume of π × 6 × 1.584 mm3, a resonance frequency of 915 MHz with a simulated bandwidth of 18 MHz (907-925 MHz), and a measured bandwidth of 18 MHz (910-928 MHz) at the return loss of -10 dB. A dielectric substrate of FR-4 of εr = 4.5 and δ = 0.02 is used for simulation and fabrication of the antenna and the rectifier due to its low cost. An L-section impedance matching circuit is employed between the antenna and the rectifier to reduce the mismatch loss. The impedance matching circuit operates as a low-pass filter eliminating higher order harmonics. A deep brain stimulation device is successfully operated by the rectenna at a distance of 20 cm away from a microwave energy transmitter of power 26.77 dBm. The motivation of this paper includes creation of a deep brain stimulation device that operates indefinitely without a battery. From the application standpoint, the developed energy harvesting rectenna facilitates long-term deep brain stimulation of laboratory animals for preclinical research investigating neurological disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Appliance-specific Load Monitoring (LM) provides a possible solution to the problem of energy conservation which is becoming increasingly challenging, due to growing energy demands within offices and residential spaces. It is essential to perform automatic appliance recognition and monitoring for optimal resource utilization. In this paper, we study the use of non-intrusive LM methods that rely on steady-state appliance signatures for classifying most commonly used office appliances, while demonstrating their limitation in terms of accurately discerning the low-power devices due to overlapping load signatures. We propose a multi-layer decision architecture that makes use of audio features derived from device sounds and fuse it with load signatures acquired from energy meter. For the recognition of device sounds, we perform feature set selection by evaluating the combination of time-domain and FFT-based audio features on the state of the art machine learning algorithms. Further, we demonstrate that our proposed feature set which is a concatenation of device audio feature and load signature significantly improves the device recognition accuracy in comparison to the use of steady-state load signatures only.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Research is being conducted on the use of transcranial direct current stimulation (tDCS) for therapeutic effects, and also on the mechanisms through which such therapeutic effects are mediated. A bottleneck in the progress of the research has been the large size of the existing tDCS systems which prevents subjects from performing their daily activities. To help research into the principles, mechanisms, and benefits of tDCS, reduction of size and weight, improvement in simplicity and user friendliness, portability, and programmability of tDCS systems are vital. This paper presents a design for a low-cost, light-weight, programmable, and portable tDCS device. The device is head-mountable and can be concealed in a hat and worn on the head by the subject while receiving the stimulation. The strength of the direct current stimulation can be selected through a simple user interface. The device is constructed and its performance evaluated through bench and in vivo tests. The tests validated the operation of the device in inducing neuromodulatory changes in primary motor cortex, M1, through measuring excitability of dominant M1 of resting right first dorsal interosseus muscle by transcranial magnetic stimulation induced motor evoked potentials. It was observed that the tDCS device induced comparable neuromodulatory effects in M1 as the existing bulky tDCS systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a portable neural recording device for use with laboratory animals. It can detect and record neural signals from the cortical region of the brain during pre-clinical trials. The device utilizes simplified circuitry to perform signal detection, filtering, sampling, and storage. It includes analog and digital components each implemented on a separate small printed circuit board. The two printed circuit boards are then attached to one another to form the device. It is capable of uninterrupted operation for over 2 hours on a single coin battery. A bench-testing of the device was performed with pre-recorded neural signal which then injected to the input of the device to give validation of efficient operation of the device. Its amplification and filtration features have been analyzed. An overall 56 dB amplification and filtration in the frequency range of 300 Hz to 4 KHz was achieved. Sampling and storage at a reduced power and computational load is demonstrated with uninterrupted storage of the neural signal. A comparison of the input and reconstructed neural signals shows minimal variation error.