21 resultados para Plasmonic circuitry

em Deakin Research Online - Australia


Relevância:

60.00% 60.00%

Publicador:

Resumo:

An atomistic understanding was garnered through large scale molecular simulations, for the adsorption and interaction of reconfigurable hybrid biomolecule components at different aqueous metallic interfaces. This would allow for the development of future hybrid biomolecular ligands that could be used to synthesise novel and tuneable materials with unique electromagnetic properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, first the fundamental concept of nano-optical biosensing is studied. Since Raman scattered signal is very weak to be recognized by current measuring equipments, the signal must be amplified. SPR and LSPR are utilized to enhance the incident field of the target molecules, to improve the sensitivity of the sensor. The paper focuses on the use of LSPR to enhance Raman signal in SERS technology. Different structures of nano-particles in LSPR to improve enhancement of the SERS signal are reviewed and compared.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Integrated optical detection is considered to be an important operation in lab-on-a-chips. This paper presents an optical fiber-based micro-sensor that is capable of detecting food substance particles in a lab-on-a-chip. The system consists of a microcontroller and associated circuitry, a laser emitter, a laser receiver, fiber optic cables, a microfluidics chip, and the food substance samples to be tested. When the particles flow through the microfluidic channel in the chip, the receiver’s output voltage varies due to the particles blocking the passage of the laser ray. The changes in the collected signals are analyzed to count the number of particles. Experiments are conducted on several food substance samples including talcum powder, ground ginger, and soy sauce. The experimental results are presented and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Deep brain stimulation has emerged as an effective method to treat certain medical conditions. Electrical charges are injected into the target tissue through a conducting electrode exciting the tissue. A variety of DBS devices have been developed based on different operation principles. Majority of these devices, however, employ complex circuitry and are bulky. In clinical trials, laboratory animals need to freely move around and perform activities whilst receiving brain stimulation for days. This paper presents a simple lightweight head mountable deep brain stimulation device that can be carried by the animal during the course of a clinical trial. The device produces continuous current pulses of specific characteristics. It employs passive charge balancing to minimize undesirable effects on the target tissue. The device is constructed and its performance tested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ability of skeletal muscle to enhance lipid utilization during exercise is a form of metabolic plasticity essential for survival. Conversely, metabolic inflexibility in muscle can cause organ dysfunction and disease. Although the transcription factor Kruppel-like factor 15 (KLF15) is an important regulator of glucose and amino acid metabolism, its endogenous role in lipid homeostasis and muscle physiology is unknown. Here we demonstrate that KLF15 is essential for skeletal muscle lipid utilization and physiologic performance. KLF15 directly regulates a broad transcriptional program spanning all major segments of the lipid-flux pathway in muscle. Consequently, Klf15-deficient mice have abnormal lipid and energy flux, excessive reliance on carbohydrate fuels, exaggerated muscle fatigue, and impaired endurance exercise capacity. Elucidation of this heretofore unrecognized role for KLF15 now implicates this factor as a central component of the transcriptional circuitry that coordinates physiologic flux of all three basic cellular nutrients: glucose, amino acids, and lipids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Object  In a companion study, the authors describe the development of a new instrument named the Wireless Instantaneous Neurotransmitter Concentration System (WINCS), which couples digital telemetry with fast-scan cyclic voltammetry (FSCV) to measure extracellular concentrations of dopamine. In the present study, the authors describe the extended capability of the WINCS to use fixed potential amperometry (FPA) to measure extracellular concentrations of dopamine, as well as glutamate and adenosine. Compared with other electrochemical techniques such as FSCV or high-speed chronoamperometry, FPA offers superior temporal resolution and, in combination with enzyme-linked biosensors, the potential to monitor nonelectroactive analytes in real time.

Methods  The WINCS design incorporated a transimpedance amplifier with associated analog circuitry for FPA; a microprocessor; a Bluetooth transceiver; and a single, battery-powered, multilayer, printed circuit board. The WINCS was tested with 3 distinct recording electrodes: 1) a carbon-fiber microelectrode (CFM) to measure dopamine; 2) a glutamate oxidase enzyme–linked electrode to measure glutamate; and 3) a multiple enzyme–linked electrode (adenosine deaminase, nucleoside phosphorylase, and xanthine oxidase) to measure adenosine. Proof-of-principle analyses included noise assessments and in vitro and in vivo measurements that were compared with similar analyses by using a commercial hardwired electrochemical system (EA161 Picostat, eDAQ; Pty Ltd). In urethane-anesthetized rats, dopamine release was monitored in the striatum following deep brain stimulation (DBS) of ascending dopaminergic fibers in the medial forebrain bundle (MFB). In separate rat experiments, DBS-evoked adenosine release was monitored in the ventrolateral thalamus. To test the WINCS in an operating room setting resembling human neurosurgery, cortical glutamate release in response to motor cortex stimulation (MCS) was monitored using a large-mammal animal model, the pig.

Results   The WINCS, which is designed in compliance with FDA-recognized consensus standards for medical electrical device safety, successfully measured dopamine, glutamate, and adenosine, both in vitro and in vivo. The WINCS detected striatal dopamine release at the implanted CFM during DBS of the MFB. The DBS-evoked adenosine release in the rat thalamus and MCS-evoked glutamate release in the pig cortex were also successfully measured. Overall, in vitro and in vivo testing demonstrated signals comparable to a commercial hardwired electrochemical system for FPA.

Conclusions  By incorporating FPA, the chemical repertoire of WINCS-measurable neurotransmitters is expanded to include glutamate and other nonelectroactive species for which the evolving field of enzyme-linked biosensors exists. Because many neurotransmitters are not electrochemically active, FPA in combination with enzyme-linked microelectrodes represents a powerful intraoperative tool for rapid and selective neurochemical sampling in important anatomical targets during functional neurosurgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, the effects of silver nano-spheroid size and elongation on plasmon wavelength are investigated, and the plasmon eigenvalues are formulated as a function of the radius and aspect ratio of the nano-particles. These can be used in eigenmode plasmonic interaction method to study interaction of nano-particles on each other at dipole resonance frequencies.. It is demonstrated that plasmon eigenvalues are partially linear with respect to radius and aspect ratio of the nano-spheroids. In addition, it is shown that the maximum enhancement occurs in the direction of the polarization angle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new nano-sinusoid shape has recently been proposed, which offers the advantage of more resonance wavelength tunability than that offered by other sharp-tip nano-particles. In this paper, a one-dimensional (1D) chain of the nano-sinusoids is modelled, and results are compared with those describing chains of nano-triangles and nano-diamonds. It is demonstrated that the chain of nano-sinusoids provides more enhancement at hot spots than other examined nano-particle shapes. This enhancement is analytically quantified using the coupling constant values used in the electrostatic eigenmode method for analytically solving Maxwell's equations for the nano-plasmonic devices. In addition, investigating LSPR spectrum of two-dimensional (2D) arrays of NPs demonstrates existence of enhanced surface electric fields on hot spots of the outer rows of the array.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By integrating together VO2’s unique near-room-temperature (RT) semiconductor–metal (S–M) phase transition with a thin silver (Ag) layer’s plasmonic properties, VO2/Ag multilayers could present a much enhanced optical transmission change when increasing the temperature from RT to over VO2’s S–M phase-transition temperature. Changing VO2 and Ag layer thicknesses can also significantly tune their transmission and absorption properties, which could lead to a few useful designs in optoelectronic and energy-saving industries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Deep brain stimulation has emerged as an effective medical procedure that has therapeutic efficacy in a number of neuropsychiatric disorders. Preclinical research involving laboratory animals is being conducted to study the principles, mechanisms, and therapeutic effects of deep brain stimulation. A bottleneck is, however, the lack of deep brain stimulation devices that enable long term brain stimulation in freely moving laboratory animals. Most of the existing devices employ complex circuitry, and are thus bulky. These devices are usually connected to the electrode that is implanted into the animal brain using long fixed wires. In long term behavioral trials, however, laboratory animals often need to continuously receive brain stimulation for days without interruption, which is difficult with existing technology. This paper presents a low power and lightweight portable microdeep brain stimulation device for laboratory animals. Three different configurations of the device are presented as follows: 1) single piece head mountable; 2) single piece back mountable; and 3) two piece back mountable. The device can be easily carried by the animal during the course of a clinical trial, and that it can produce non-stop stimulation current pulses of desired characteristics for over 12 days on a single battery. It employs passive charge balancing to minimize undesirable effects on the target tissue. The results of bench, in-vitro, and in-vivo tests to evaluate the performance of the device are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A biosynthetic platform composed of a conducting polypyrrole sheet embedded with unidirectional biodegradable polymer fibers is described (see image; scale bar = 50 µm). Such hybrid systems can promote rapid directional nerve growth for neuro-regenerative scaffolds and act as interfaces between the electronic circuitry of medical bionic devices and the nervous system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes research into three different but interrelated technologies that can add value to commodity printing substrates by taking advantage of developments in synthetic chemistry, materials science and plasma physics. These investigations have been conducted in a Cooperative Research Centre (CRC) in Australia, called CRC Smartprint. Research into ink receptive coatings based on pigments possessing a positive surface charge has led to coatings that display improved resolution and colour saturation compared with silica based formulations. Although silica exhibits a high level of liquid absorption, it has relatively poor affinity for dye molecules contained in ink-jet ink. The second development involves the use of plasma enhanced chemical vapour deposition at atmospheric pressure to change surface functionality with particular emphasis on absorptive and printing properties. Thirdly, the development of a prototype labelling system based on the application of electrochromic conductive polymer to a flexible substrate that responds to electrical stimuli is discussed. Taken together, these three developments illustrate how both impact and non-impact printing technologies can be judiciously used to apply not only improved visual imagery to paper and paperboard, but also have the potential to enable printing of micro-electronic circuitry directly onto packaging materials, or onto labels that will enable a wide range of improved tracking, security and marketing functions to be incorporated cost-effectively into packaged goods in future.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Design of a rectangular spiral planar inverted-F antenna (PIFA) at 915 MHz for wireless power transmission applications is proposed. The antenna and rectifying circuitry form a rectenna, which can produce dc power from a distant radio frequency energy transmitter. The generated dc power is used to operate a low-power deep brain stimulation pulse generator. The proposed antenna has the dimensions of 10 mm × 12.5 mm × 1.5 mm and resonance frequency of 915 MHz with a measured bandwidth of 15 MHz at return loss of -10 dB. A dielectric substrate of FR-4 of εr = 4.8 and δ = 0.015 with thickness of 1.5 mm is used for both antenna and rectifier circuit simulation and fabrication because of its availability and low cost. An L-section impedance matching circuit is used between the PIFA and voltage doubler rectifier. The impedance matching circuit also works as a low-pass filter for elimination of higher order harmonics. Maximum dc voltage at the rectenna output is 7.5 V in free space and this rectenna can drive a deep brain stimulation pulse generator at a distance of 30 cm from a radio frequency energy transmitter, which transmits power of 26.77 dBm.