24 resultados para ORTHOPEDIC IMPLANTS

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydroxyapatite (HAp) is commonly used to coat titanium alloys (Ti–6Al–4V) for orthopedic implants. However, their poor adhesion strength and insufficient long-term stability limit their application. Novel sphene (CaTiSiO5) ceramics possess excellent chemical stability and cytocompatibility. The aim of this study is to use the novel sphene ceramics as coatings for Ti–6Al–4V. The sol–gel method was used to produce the coatings and the thermal properties, phase composition, microstructure, thickness, surface roughness and adhesion strength of sphene coatings were analyzed by differential thermal analysis–thermal gravity (DTA–TG), X-ray diffraction (XRD), scanning electron microscopy (SEM), atom force microscopy (AFM) and scratch test, respectively. DTA analysis confirmed that the temperature of the sphene phase formation is 875 °C and XRD analysis indicated pure sphene coatings were obtained. A uniform structure of the sphene coating was found across the Ti–6Al–4V surface, with a thickness and surface roughness of the coating of about 0.5–1 μm and 0.38 μm, respectively. Sphene-coated Ti–6Al–4V possessed a significantly improved adhesion strength compared to that for HAp coating and their chemical stability was evaluated by testing the profile element distribution and the dissolution kinetics of calcium (Ca) ions after soaking the sphene-coated Ti–6Al–4V in Tris–HCl solution. Sphene coatings had a significantly improved chemical stability compared to the HAp coatings. A layer of apatite formed on the sphene-coated Ti–6Al–4V after they were soaked in simulated body fluids (SBF). Our results indicate that sol–gel coating of novel sphene onto Ti–6Al–4V possessed improved adhesion strength and chemical stability, compared to HAp-coated Ti–6Al–4V prepared under the same conditions, suggesting their potential application as coatings for orthopedic implants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The development of artificial organs and implants for replacement of injured and diseased hard tissues such as bones, teeth and joints is highly desired in orthopedic surgery. Orthopedic prostheses have shown an enormous success in restoring the function and offering high quality of life to millions of individuals each year. Therefore, it is pertinent for an engineer to set out new approaches to restore the normal function of impaired hard tissues.

Over the last few decades, a large number of metals and applied materials have been developed with significant improvement in various properties in a wide range of medical applications. However, the traditional metallic bone implants are dense and often suffer from the problems of adverse reaction, biomechanical mismatch and lack of adequate space for new bone tissue to grow into the implant. Scientific advancements have been made to fabricate porous scaffolds that mimic the architecture and mechanical properties of natural bone. The porous structure provides necessary framework for the bone cells to grow into the pores and integrate with host tissue, known as osteointegration. The appropriate mechanical properties, in particular, the low elastic modulus mimicking that of bone may minimize or eliminate the stress-shielding problem. Another important approach is to develop biocompatible and corrosion resistant metallic materials to diminish or avoid adverse body reaction. Although numerous types of materials can be involved in this fast developing field, some of them are more widely used in medical applications. Amongst them, titanium and some of its alloys provide many advantages such as excellent biocompatibility, high strength-to-weight ratio, lower elastic modulus, and superior corrosion resistance, required for dental and orthopedic implants. Alloying elements, i.e. Zr, Nb, Ta, Sn, Mo and Si, would lead to superior improvement in properties of titanium for biomedical applications.

New processes have recently been developed to synthesize biomimetic porous titanium scaffolds for bone replacement through powder metallurgy. In particular, the space holder sintering method is capable of adjusting the pore shape, the porosity, and the pore size distribution, notably within the range of 200 to 500 m as required for osteoconductive applications. The present chapter provides a review on the characteristics of porous metal scaffolds used as bone replacement as well as fabrication processes of porous titanium (Ti) scaffolds through a space holder sintering method. Finally, surface modification of the resultant porous Ti scaffolds through a biomimetic chemical technique is reviewed, in order to ensure that the surfaces of the scaffolds fulfill the requirements for biomedical applications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Development of new biodegradable implants and devices is necessary to meet the increasing needs of regenerative orthopedic procedures. An important consideration while formulating new implant materials is that they should physicochemically and biologically mimic bone-like properties. In earlier studies, we have developed and characterized magnesium based biodegradable alloys, in particular magnesium-zirconium (Mg-Zr) alloys. Here we have reported the biological properties of four Mg-Zr alloys containing different quantities of strontium or calcium. The alloys were implanted in small cavities made in femur bones of New Zealand White rabbits, and the quantitative and qualitative assessments of newly induced bone tissue were carried out. A total of 30 experimental animals, three for each implant type, were studied, and bone induction was assessed by histological, immunohistochemical and radiological methods; cavities in the femurs with no implants and observed for the same period of time were kept as controls. Our results showed that Mg-Zr alloys containing appropriate quantities of strontium were more efficient in inducing good quality mineralized bone than other alloys. Our results have been discussed in the context of physicochemical and biological properties of the alloys, and they could be very useful in determining the nature of future generations of biodegradable orthopedic implants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The successful applications of magnesium (Mg) alloys as biodegradable orthopedic implants are mainly restricted due to their rapid degradation rate in the physiological environment, leading to a loss of mechanical integrity. This study systematically investigated the degradation behaviors of novel Mg-Zr-Sr alloys using electrochemical techniques, hydrogen evolution, and weight loss in simulated body fluid (SBF). The microstructure and degradation behaviors of the alloys were characterized using optical microscopy, XRD, SEM, and EDX. The results indicate that Zr and Sr concentrations in Mg alloys strongly affected the degradation rate of the alloys in SBF. A high concentration of 5 wt% Zr led to acceleration of anodic dissolution, which significantly decreased the biocorrosion resistance of the alloys and their biocompatibility. A high volume fraction of Mg17Sr2 phases due to the addition of excessive Sr (over 5 wt%) resulted in enhanced galvanic effects between the Mg matrix and Mg17Sr2 phases, which reduced the biocorrosion resistance. The average Sr release rate is approximately 0.15 mg L-1 day-1, which is much lower than the body burden and proves its good biocompatibility. A new biocorrosion model has been established to illustrate the degradation of alloys and the formation of degradation products on the surface of the alloys. It can be concluded that the optimal concentration of Zr and Sr is less than 2 wt% for as-cast Mg-Zr-Sr alloys used as biodegradable orthopedic implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The Medical Outcomes General Health Survey (SF-36) is a widely used health status measure; however, limited evidence is available for its performance in orthopedic settings. The aim of this study was to examine the magnitude and meaningfulness of change and sensitivity of SF-36 subscales following orthopedic surgery.

Methods: Longitudinal data on outcomes of total hip replacement (THR, n = 255), total knee replacement (TKR, n = 103), arthroscopic partial meniscectomy (APM, n = 74) and anterior cruciate ligament reconstruction (ACL, n = 62) were used to estimate the effect sizes (ES, magnitude of change) and minimal detectable change (sensitivity) at the group and individual level. To provide context for interpreting the magnitude of changes in SF-36 scores, we also compared patients' scores with age and sex-matched population norms. The studies were conducted in Sweden. Follow-up was five years in THR and TKR studies, two years in ACL, and three months in APM.

Results:
On average, large effect sizes (ES≥0.80) were found after orthopedic surgery in SF-36 subscales measuring physical aspects (physical functioning, role physical, and bodily pain). Small (0.20–0.49) to moderate (0.50–0.79) effect sizes were found in subscales measuring mental and social aspects (role emotional, vitality, social functioning, and mental health). General health scores remained relatively unchanged during the follow-up. Despite improvements, post-surgery mean scores of patients were still below the age and sex matched population norms on physical subscales. Patients' scores on mental and social subscales approached population norms following the surgery. At the individual level, scores of a large proportion of patients were affected by floor or ceiling effects on several subscales and the sensitivity to individual change was very low.

Conclusion: Large to moderate meaningful changes in group scores were observed in all SF-36 subscales except General Health across the intervention groups. Therefore, in orthopedic settings, the SF-36 can be used to show changes for groups in physical, mental, and social dimensions and in comparison with population norms. However, SF-36 subscales have low sensitivity to individual change and so we caution against using SF-36 to monitor the health status of individual patients undergoing orthopedic surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the finite element modeling and comparison of the stress and strain analyses were carried out for three different structures that are intact bone, stemless implant and stemmed one. Currently proposed stemless design studied here is the generic concept of stemless implant. This generic stemless implant reconstruction was numerically compared to the conventional stemmed implant and also to the intact bone as control solution. Two loading conditions were applied to the most proximal part of the models, while the most distal part was fixed for all degrees of freedom. The models were divided into two regions and studied along two paths of medial and lateral aspect. The results of this study showed that the stemless implant had less deviation from the control solution of the bone in all regions and in both loading conditions, comparing to the large deviation of the stemmed implant from the intact bone. However, it was shown that the fixation of this type of implant and its effect on sub-trochanter region must be carefully considered for designing the final product of any specific design of stemless implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interest in using titanium (Ti) alloys as load-bearing implant materials has increased due to their high strength to weight ratio, lower elastic modulus, and superior biocompatibility and enhanced corrosion resistance compared to conventional metals such as stainless steel and Co-Cr alloys. In the present study, the in vitro cytotoxicity of five binary titanium alloys, Ti15Ta, Ti15Nb, Ti15Zr, Ti15Sn and Ti15Mo, was assessed using human osteosarcoma cell line, SaOS-2 cells. The Cell proliferation and viability were determined, and cell adhesion and morphology on the surfaces of the binary Ti alloys after cell culture were observed by SEM. Results indicated that the Ti binary alloys of Ti15Ta, Ti15Nb and Ti15Zr exhibited the same level of excellent biocompatibility; Ti15Sn alloy exhibited a moderate biocompatibility while Ti15Mo alloy exhibited a moderate cytotoxicity. The SaOS-2 osteoblast-like cells had flattened and spread across the surfaces of the Ti15Ta, Ti15Nb, Ti15Zr and Ti15Sn groups; however, the cell shapes on the Ti15Mo alloy was shrinking and unhealthy. These results indicated that the Mo contents should be limited to a certain level in the design and development of new Ti alloys for implant material applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, to enhance the strength of porous pure titanium scaffolds with high porosity, new particulate-reinforced Ti-based composites with the addition of biocompatible oxide particles such as TiO2, SiO2, ZrO2 and Nb2O5 were prepared using a powder metallurgical method. The strengths of the new particulate-reinforced titanium composites were found to be significantly higher than that of pure titanium with an excellent biocompatibility. SaOS-2 osteoblast-like cells grew and spread well on the surfaces of the new particulate-reinforced titanium composites. The present study illustrated the feasibility of using the particulate-reinforced titanium composites as an orthopaedic implant material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medical textiles are a highly specialised stream of technical textiles industry with a growing range of applications. A significant advancement has been achieved in surgical products or biomedical textiles (implantable/non-implantable) with the advent of 3D textile manufacturing techniques. Cardiovascular soft tissue implants (vascular grafts) have been a field of interest over decades for use of innovative 3D tubular structures in treatment of cardiovascular diseases. In the field of soft tissue implants, knitted and woven tubular structures are being used for large diameter blood vessel replacements. Advent of electrospinning and tissue engineering techniques has been able to provide promising answers to small diameter vascular grafts. The aim of this review is to outline the approaches in vascular graft development utilising different 3D tubular structure forming techniques. The emphasis is on vascular graft development techniques that can help improve treatment efficacy in future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents design and simulation of a miniature rectangular spiral planar inverted-F antenna (PIFA) at UHF RFID band (902.75 - 927.25 MHz) for integration in batteryless deep brain stimulation implants. Operation in the UHF band offers small antenna size and longer transmission range. The proposed antenna has the dimensions of 10 mm × 11.5 mm × 1.6 mm, resonance frequency of 920 MHz with a bandwidth of 18 MHz at return loss of -10 dB. A dielectric substrate of FR-4 of εr = 4.5 and δ = 0.018 with thickness of 1.5644 mm is used in this design. The resonance, radiation characteristics as well as the specific absorption rate distribution induced by the designed antenna within a four layer spherical head model is evaluated by using electromagnetic modeling software which employs the finite element method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A compact meandered three-layer stacked circular planar inverted-F antenna is designed and simulated at the UHF band (902.75 – 927.25 MHz) for passive deep brain stimulation implants. The UHF band is used because it offers small antenna size, and high data rate. The top and middle radiating layers are meandered, and low cost substrate and superstrate materials are used to limit the radius and height of the antenna to 5 mm and 1.64 mm, respectively. A dielectric substrate of FR-4 of εr= 4.7 and δ= 0.018, and a biocompatible superstrate of silicone of er= 3.7 and d= 0.003 with thickness of 0.2 mm are used in the design. The resonance frequency of the proposed antenna is 918 MHz with a bandwidth of 24 MHz at return loss of −10 dB in free space. The antenna parameter such as 3D gain pattern of the designed antenna within a skin-tissue model is evaluated by using the finite element method. The compactness, wide bandwidth, round shape, and stable characteristics in skin make this antenna suitable for DBS. The feasibility of the wireless power transmission to the implant in the human head is also examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Children with cochlear implants have been shown to have language skills on a par with children with severe hearing losses who have hearing aids. Earlier implants, bilateral implantation, and focused intervention programmes may result in some children with cochlear implants displaying similar language skills to their hearing peers. The development of pragmatic skills is central to communication competence and underpins the development of friendships. Although some studies of pragmatic skills in children with cochlear implants have been reported, most have used a contrived referential communication task rather than free conversation.

Method: This study investigated the conversational skills of 20 children with cochlear implants, aged between 9 and 12 years, in free conversation with their hearing peers. The pragmatic skills of these 20 deaf/hearing pairs or dyads were compared with the pragmatic skills of 20 hearing/hearing dyads. Pragmatic skills were analysed in terms of conversational balance, conversational turn types, and conversational maintenance. The impact of the participants’ level of speech intelligibility was also investigated.

Results: Children with cochlear implants tend to dominate conversations with their hearing peers. They initiated more topics, took longer turns, asked more questions, and tended to make more personal comments while their hearing friends tended to use more conversational devices and minimal answers. In contrast, pairs of matched hearing children were very balanced in all of these aspects of conversation. Speech intelligibility did not appear to impact consistently on the pragmatic skills of the children with cochlear implants but all children had a relatively high level of speech intelligibility.

Discussion: Rather than being characterized by frequent conversational breakdown as in older studies, children with cochlear implants had a strong grasp of basic conversational rules. They conversed in a similar way to some deaf adults who also have been shown to take control of the conversation. Findings are discussed for their implications for intervention and future research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distal clavicle fracture associated with complete coracoclavicular ligament disruption represents an unstable injury, and osteosynthesis is recommended. This study was performed (1) to retrospectively analyse the clinico-radiological outcomes of two internal fixation techniques, and (2) to identify and analyse radiographic fracture patterns of fracture that are associated with this injury. Conclusions: Internal fixation of this fracture pattern is associated with a high union rate and favorable clinical outcomes with both techniques. A combination of distal radius plate and ligament reconstruction device resulted in stable fixation and significantly lower reoperation rates, and should be used when fracture geometry permits (Types 1 and 2).