10 resultados para OPC

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the results of an investigation that studied the effects of admixed polypropylene (PP) fibres on the long-term drying shrinkage of hardened concrete. Five concrete mixtures, made with 100% Ordinary Portland Cement (OPC) as the binder and containing different volume fractions of PP fibre (0%, 0.05%, 0.1%, 0.2% and 0.5%) were tested. Also, three concrete mixtures were made with 65 % slag-blended cement binder incorporating 0% and 0.2% volume fraction of PP. The results show higher water loss and higher drying shrinkages in concretes that incorporate PP fibres than concrete without fibre. The results of early age cracking tendency of slag concrete, with and without fibre, under fully restrained and drying conditions, show that that PP fibre concrete had higher cracking tendency than concrete without fibre. Higher cracking tendency of PP fibre concrete was due to higher drying shrinkage and elastic moduli.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OLE Process Control (OPC) is an industry standard that facilitates the communication between PCs and Programmable Logic Controllers (PLC). This communication allows for the testing of control systems with an emulation model. When models require faster and higher volume communications, limitations within OPC prevent this. In this paper an interface is developed to allow high speed and high volume communications between a PC and PLC enabling the emulation of larger and more complex control systems and their models. By switching control of elements within the model between the model engine and the control system it is possible to use the model to validate the system design, test the real world control systems and visualise real world operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports on the second phase of a research project aimed at the development of an environmentally friendly noise barrier for urban freeways, also known as KMAK (Krezel and McManus, 2007). The concrete barrier, which has some unique capabilities to mitigate transportation noise, is made from recycled concrete (RC) aggregate and industrial by-products such as fly ash and reclaimed water. The current developmental work expands on a research project that resulted in a two-layer (2L) concrete barrier. Two prototypes of the 2L barrier were produced, followed by extensive acoustic testing and a number of simulations where standard timber and/or concrete barriers were substituted with KMAK barrier (Krezel et al, 2004). Current research investigates a variety of architectural finishes applied to the original KMAK barrier with the aim of improving its visual appearance and also fine-tuning its acoustic performance. The new three-layer (3L) barrier optimises sound absorption in a frequency range characteristic to that of transportation noise, especially road traffic noise. Three major aspects related to the development of architectural finishes were considered; environmentally responsible materials, surface features and production methods. The light-weight material used in the architectural finish is based on ordinary Portland cement (OPC) and uses very fine fraction of RC aggregate. The manufacturing process of the 3L barrier was tested in a commercial setting and two sets of prototype barrier were cast. An innovative, cost effective method of applying pattern and perforation to the surface of architectural finish was also developed and tested. The findings of the current investigation demonstrate that there is a positive correlation between surface features, percentage of perforation as well as depth of the architectural layer and increased potential of the 3L barrier to mitigate transportation noise. On average, the addition of perforated architectural finish contributes to 20% increase in sound absorption. The preliminary results also show that the sound absorbency of the 3L barrier can be better controlled and tuned to specific noise frequency. The visual appearance has been significantly improved with the addition of the architectural finish, which makes the barrier an attractive, feasible and viable alternative to road barriers made from standard concrete or timber.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Diabetes is the major cause of chronic kidney disease (CKD) in Australia. Anaemia of CKD occurs earlier than in non-diabetics and is often insidious and undetected.

Aim:
A large, prospective, single-centre study was undertaken to determine the feasibility of point of care testing (POCT) haemoglobin (Hb) and microalbumin in people with type 2 diabetes (T2DM) attending routine outpatient clinic appointments (OPC).

Method: Clinic nurses measured Hb and microalbumin using the HemoCue Haemoglobin Capillary Analyser and the HemoCue Urine Albumin Analyser (Medipac Scientific), respectively when they tested blood glucose, weight and blood pressure. The nurses were trained to use the analysers before the study commenced. Standard demographic data, duration of diabetes, treatment mode, and presence of complications, comorbidities, and HbA1c were ascertained from patients’ medical records.

Results: Five hundred and fifty-four (80%) patients were screened. The nurses were able to perform the tests competently but testing, especially microalbumin, was time-consuming. Patients’ mean age was 62 years (11 SD): 230 females, mean blood glucose (BG) 10 (3.9 SD) mmol/L, mean haemoglobin 127.2 (16.3 SD) g/L; mean microalbumin 47.8 (58.7 SD) mg/L: 324 were males, mean BG 10.2 (3.9 SD) mmol/L, mean Hb 138.6 (18.8 SD) gm/L, and mean microalbumin 67.9 (73.9 SD) mg/L. 27% of males and 22% of females were anaemic. Of those with anaemia, 27% of females and 29% of males had microalbuminuria.

Conclusions:
POCT is feasible in routine outpatient clinics but is time-consuming. One in four T2DM attending OPC were anaemic. POCT Hb testing in OPC is feasible and could identify T2DM who need full haematological assessment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Any organisation that captures personal data in Canada for processing is deemed tohave a ‘real and substantial connection’ to Canada and thus fall within thejurisdiction of the Personal Information Protection and Electronic Documents Act(PIPEDA) and of the Office of the Privacy Commissioner of Canada (OPC). Whathas been the experience of enforcing Canadian privacy protection law on US-basedsocial networking services? We analyse some of the high-profile enforcement actionsby the Privacy Commissioner. We also test compliance through an analysis of theprivacy policies of the top 23 SNSs operating in Canada and through the use of accessto personal information requests. Our analysis suggests that non-compliance iswidespread, and is explained by the countervailing conceptions of jurisdictioninherent in corporate policy and technical system design.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose – Construction contractors and facility managers are being challenged to minimize the carbon footprint. Life cycle carbon‐equivalent (CO2‐e) accounting, whereby the potential emissions of greenhouse gases due to energy expenditure during construction and subsequent occupation of built infrastructure, generally ceases at the end of the service life. However, following demolition, recycling of demolition waste that becomes incorporated into 2nd generation construction is seldom considered within the management of the carbon footprint. This paper aims to focus on built concrete infrastructure, particularly the ability of recycled concrete to chemically react with airborne CO2, thereby significantly influencing CO2‐e estimates.

Design/methodology/approach – CO2‐e estimates were made in accordance with the methodology outlined in the Australian National Greenhouse Accounts (NGA) Factors and were based on the energy expended for each life cycle activity from audited records. Offsets to the CO2‐e estimates were based on the documented ability of concrete to chemically react with airborne carbon dioxide (“carbonation”) and predictions of CO2 uptake by concrete and recycled concrete was made using existing predictive diffusion models. The author's study focused on a built concrete bridge which was demolished and recycled at the end of the service life, and the recycled concrete was utilized towards 2nd generation construction. The sensitivity of CO2‐e and carbonation estimates were tested on several different types of source demolition waste as well as subsequent construction applications using recycled concrete (RCA). Whole‐of‐life CO2‐e estimates, including carbonation of RCA over the 1st and 2nd generations, were estimated and contrasted with conventional carbon footprints that end at the conclusion of the 1st generation.

Findings – Following demolition, CO2 capture by RCA is significant due to the more permeable nature of the crushed RCA compared with the original built infrastructure. RCA also has considerably greater exposed surface area, relative to volume, than a built concrete structure, and therefore more highly exposed surface to react with CO2: it therefore carbonates more comprehensively. CO2‐e estimates can be offset by as much as 55‐65 per cent when including the contribution of carbonation of RCA built within 2nd generation infrastructure. Further offsets are achievable using blended fly ash or slag cement binders; however, this study has focused on concrete composed of 100 per cent OPC binders and the effects of RCA.

Originality/value – Construction project estimates of life cycle CO2‐e emissions should include 2nd generation applications that follow the demolition of the 1st generation infrastructure. Life cycle estimates generally end at the time of demolition. However, by incorporating the recycled concrete demolition waste into the construction of 2nd generation infrastructure, the estimated CO2‐e is significantly offset during the 2nd generation life cycle by chemical uptake of CO2 (carbonation). This paper provides an approach towards inclusion of 2nd generation construction applications into whole‐of‐life estimates of CO2‐e.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of strain rate on compressive and tensile strength of fly ash based geopolymer concrete were investigated experimentally. Four mixes of geopolymer concrete using different alkaline solutions and under vary curing conditions were prepared. One mix of ordinary Portland cement (OPC) concrete was prepared for comparison. Both Quasi-Static tests using standard MTS and dynamic tests using Split-Hopkinson pressures bar (SHPB) were conducted, which were giving varying strain rate loadings from 10‾⁷ to 103 per second. The strain rate effect is presented as the ratio of dynamic compressive strength to static compressive strength (DIF). Results show that DIFs of geopolymer concrete are generally higher than those of OPC concrete at strain range of 187/s to 346/s (compression tests) and 7/s to 13/s (splitting tensile tests), respectively. This tendency is independent on loading regimes (compression or tension). This suggests that geopolymer concrete can be used as an alternative construction material to OPC concrete for the structures which has a high risk of being subjected to impact loadings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As environmentally-friendly materials, geopolymers have the potential to replace ordinary Portland cement (OPC) for the construction of railway sleepers and multi-flue chimneys, where the vibration control capabilities of the material must be considered. The critical damping value (ξ) is the main parameter in relation to vibration reduction. In this study, the traditional logarithmic decrement technique was used to measure the ξ of geopolymers. Geopolymers were prepared by activating fly ash using alkali solutions with different SiO2/Na2O ratios. The results show that the ξ of the geopolymers is similar to that of the OPC counterpart. Finite element analysis (FEM) based on the Rayleigh damping model was conducted to replicate the test results, and scanning electron microscopy and mercury-intrusion porosimetry were used to study the microstructure of the geopolymers. A discussion of the possible damping mechanisms based on the microstructural investigation and the FEM analysis is presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Significant research advances have been made in the field of carbon nanotube (CNT) reinforced ordinary Portland cement (OPC) paste composites in recent years. However, the distribution of CNTs in fresh OPC paste is yet to be fully researched and quantified, thereby creating a technical barrier to CNT utilization in concrete construction. In this study, fresh OPC paste was treated as a two-phase material containing solid particles (cement grains) and liquid solutions (pore solutions). A centrifugation-based technique was proposed to separate these two phases and the presence of CNTs in each phase was quantified. UV-Vis spectrometry showed that the degree of dispersion can achieve above 90 wt% using polycarboxylate superplasticizer. The results suggested an upper limit of 0.26 wt% for CNT addition into water before mixing with OPC, and the dispersion was found to be stable for at least 4 hours. Based on scanning electron imaging, the adsorption phenomenon of CNTs on OPC grains with size less than 4 μm was discovered. Energy-dispersive X-ray spectroscopy indicated these adsorptive particles have lower Ca to Si ratio. It was observed that about 0.5 mg of CNTs per gram of OPC grains was adsorbed in solid OPC grains in typical fresh OPC pastes. On the basis of these results, a conceptual model was proposed for the distribution of CNTs in fresh OPC paste where about 33 wt% of the CNTs stay in pore solution and 65 wt% of CNTs are adsorbed on OPC grains.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

New infrastructure, particularly in the developing countries, demands substantial capital investment and a loss of durability of the concrete means a waste of oportunity. Improving durability of concrete structures is a non-trivial task. The durability of concrete has been related to its ability to resist the transport of water and the potentail imporvements to concrete durability using supplementary cementitious materials (SCM) has been well documented. With access to neutron and synchrotron facilities it has become possible to; (a) measure the ability of SCM to inhibit transport of water in concrete (b) measure particle size increase of hydrating cements (with and without SCM) by ultra-small angle neutron scattering (c) use neutron tomography combined with x-ray tomography to determine the three dimensional flaws in the structure of concretes that enable water ingress into structures, and (d) determine the amount of curing or degree of hydration on the durability of SCM/OPC blends. This review will detail preliminary results on cement and concrete obtained using the newly available neutron, synchrotron and other facilities in Australia and Brazil and highlights their ability to estimate factors which determine the service life of concrete