45 resultados para ON-A-CHIP

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the design and simulation of a novel passive micromixer. The micromixer consists of two inlet tanks, one mixing channel and two outlet channels. In order to maximise the mixing efficiency, the following considerations are made: (i) The inlet tanks are followed by a series of microchannels, in which the flow is split. The microchannels are arranged in an interdigital manner to maximise the contact area between the two flows. (ii) The microchannels attached to the lower inlet tank have an upward slope while those attached to the upper tank have a downward slope. The higher-density flow is fed to the lower inlet tank and gets an upward velocity before entering the mixing channel. (iii) Two triangular barriers are placed within the mixing channel to impose chaotic advection and perturb the less-mixed flow along the top and bottom surfaces of the channel. (iv) Finally, two outlet channels are incorporated to discard the less-mixed flow. Three-dimensional simulations are carried out to evaluate the performance of the micromixer. Simulations are performed in the absence and presence of the gravitational force to analyse the influence of gravity on the micromixer. Mixing efficiencies of greater than 92% are achieved using water and a 1011'density biological solvent as the mixing fluids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper presents the design and simulation of a novel passive micromixer. The micromixer consists of two inlet tanks, one mixing channel and two outlet channels. In order to maximise the mixing efficiency, the following considerations are made : (i) The inlet tanks are followed by a series of microchannels, in which the flow is split. The microchannels are arranged in an interdigital manner to  maximise the contact area between the two flows. (ii) The microchannels attached to the lower inlet tank have an upward slope while those attached to the upper tank have a downward slope. The higher-density flow is fed to the lower inlet tank and gets an upward velocity before entering the mixing channel. (iii) Two triangular barriers are placed within the mixing channel to impose chaotic advection and perturb the less-mixed flow along the top and bottom surfaces of the channel. (iv) Finally, two outlet channels are incorporated to discard the less-mixed flow. Three-dimensional simulations are carried out to evaluate the performance of the micromixer. Simulations are performed in the absence and presence of the gravitational force to analyse the influence of gravity on the micromixer. Mixing efficiencies of greater than 92 % are achieved using water and a low-density biological solvent as the mixing fluids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a review of the recent trends and developments in non-optical biosensing platforms for lab-on- a-chip systems. This includes design considerations and applications of the non-optical biosensing platforms. The paper first categorizes the non-optical biosensors into four groups. The definition of each group together with a review of the reported works associated with the group are given. A performance analysis of different non-optical detection methods is also presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Miniaturization is being increasingly applied to biological and chemical analysis processes. Lab-on-a-chip systems are direct creation of the advancement in the miniaturization of these processes. They offer a host of exciting applications in several areas including clinical diagnostics, food and environmental analysis, and drug discovery and delivery studies. This paper reviews lab-on-a-chip systems from their components perspective. It provides a categorization of the standard functional components found in lab-on-a-chip devices together with an overview of the latest trends and developments related to lab-on-a-chip technologies and their application in nanobiotechnology. The functional components include: injector, transporter, preparator, mixer, reactor, separator, detector, controller, and power supply. The components are represented by appropriate symbols allowing designers to present their lab-on-a-chip products in a standard manner. Definition and role of each functional component are included and complemented with examples of existing work. Through the approach presented in this paper, it is hoped that modularity and technology transfer in lab-on-a-chip systems can be further facilitated and their application in nanobiotechnology be expanded.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent years have brought enormous progress in cell-based lab-on-a-chip technologies, allowing dynamic studies of cell death with an unprecedented accuracy. As interest in the microfabricated technologies for cell-based bioassays is rapidly gaining momentum, we highlight the most promising technologies that provide a new outlook for the rapid assessment of programmed and accidental cell death and are applicable in drug discovery, high-content drug screening, and personalized clinical diagnostics.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current practice of designing microfluidic Lab-on-a-Chip (LoCs) limits reusing designs and makes sharing tasks among researchers difficult. One way to achieve that objective is to borrow best practices from engineering. Also it takes a lot of skills to design LoCs. Design-by-assembly in which a LoC can be designed by configuring, laying out subsystems can help new researchers to develop custom chips. Flexible, reusable, and rapid-prototyping-feasible LoC designs can be achieved by fabricated modular microfluidic blocks. However, challenging problems still persist, which limit the usefulness of prefabricated blocks. We propose software microfluidic modules (SoftMABs) based design technique to solve issues fabricated modules face. By configuring SoftMABs, integrating them, the new assembly of SoftMABs can form a 3D LoC design ready to be prototyped. The proposed method can make designing a complex LoC less challenging, and collaborating among laboratories easier. We created SoftMABs and designed a custom microfluidic chip by assembling SoftMABs like LEGOs, dragging-and-dropping them. Later we reconfigured them - by replacing a SoftMAB with another module - to make a new LoC. We believe this computeraided method is an interesting and useful LoC design technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes the manufacturing and characterisation of plano-convex miniaturised lenses using a CO2 laser engraving process in PMMA substrates. The technique allows for lenses to be fabricated rapidly and in a reproducible manner at depths of over 200 µm and for lens diameters of more than 3 mm. Experimental characterisation of the lens focal lengths shows good correlation with theory. The plano-convex lenses have been successfully embedded into capillary microfluidic systems alongside planar microlenses, allowing for a significant reduction of ancillary optics without a loss of detection sensitivity when performing fluorescence measurements. Such technology provides a significant step forward towards the portability of fluorescence- or luminescence-based systems for biological/chemical analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lab-on-a-chip technology has been long envisaged to have tremendous commercial potential, owing to the ability of such devices to encapsulate a full range of laboratory processes in a single instrument and operate in a portable manner, rapidly and at low cost. Devices are believed to have potential in fields ranging across medical diagnostics, environmental sampling and a range of consumer products, however, to date very few devices have attained commercial success. This review examines the challenges relating to the commercialization of lab-on-a-chip technology from fundamental research to mass manufacturing and aims to provide insight to both academics and product development specialists the perceived hindrances to commercialization and a strategy by which future work could be translated into commercial success.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microfluidics is an emerging and promising interdisciplinary technology which offers powerful platforms for precise production of novel functional materials (e.g., emulsion droplets, microcapsules, and nanoparticles as drug delivery vehicles- and drug molecules) as well as high-throughput analyses (e.g., bioassays, detection, and diagnostics). In particular, multiphase microfluidics is a rapidly growing technology and has beneficial applications in various fields including biomedicals, chemicals, and foods. In this review, we first describe the fundamentals and latest developments in multiphase microfluidics for producing biocompatible materials that are precisely controlled in size, shape, internal morphology and composition. We next describe some microfluidic applications that synthesize drug molecules, handle biological substances and biological units, and imitate biological organs. We also highlight and discuss design, applications and scale up of droplet- and flow-based microfluidic devices used for drug discovery and delivery.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Integrated optical detection is considered to be an important operation in lab-on-a-chips. This paper presents an optical fiber-based micro-sensor that is capable of detecting food substance particles in a lab-on-a-chip. The system consists of a microcontroller and associated circuitry, a laser emitter, a laser receiver, fiber optic cables, a microfluidics chip, and the food substance samples to be tested. When the particles flow through the microfluidic channel in the chip, the receiver’s output voltage varies due to the particles blocking the passage of the laser ray. The changes in the collected signals are analyzed to count the number of particles. Experiments are conducted on several food substance samples including talcum powder, ground ginger, and soy sauce. The experimental results are presented and discussed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The first continuous flow micro PCR introduced in 1998 has attracted considerable attention for the past several years because of its ability to amplify DNA at much faster rate than the conventional PCR and micro chamber PCR method. The amplification is obtained by moving the sample through 3 different fixed temperature zones. In this paper, the thermal behavior of a continuous flow PCR chip is studied using commercially available finite element software. We study the temperature uniformity and temperature gradient on the chip’s top surface, the cover plate and the interface of the two layers. The material for the chip body and cover plate is glass. The duration for the PCR chip to achieve equilibrium temperature is also studied.