72 resultados para Neck

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this study are (1) to establish a reliable and valid quality-of-life (QOL) questionnaire for Chinese patients with head and neck (H&N) cancer who are treated with radiation therapy and (2) to evaluate the impact of the immediate side effects of treatment on the QOL of these patients. The 39-item "Quality of Life Radiation Therapy Instrument with Head and Neck Companion Module" (QOL-RTI/H&N) was translated into Chinese. In the reliability evaluation phase (study module 1), the questionnaire was administered twice to 56 H&N cancer patients, 7 days apart, during the second and third week of radiation therapy. In the validity evaluation phase (study module 2), 138 patients completed the QOL-RTI/H&N before starting and at the end of radiation therapy. Sixty-nine of these 138 patients also completed the QOL-RTI/H&N during the second week of their radiation therapy, at the same time as completing the Functional Assessment of Cancer Therapy-Head and Neck (FACT-H&N) questionnaire. Cronbach alpha coefficients were 0.88 for the general-tool QOL-RTI and 0.90 for the H&N subscale. Test-retest reliability was satisfactory with intraclass correlation coefficients of 0.89 for the general-tool QOL-RTI and 0.75 for the H&N subscale. The instrument can discriminate between patients with stage I or II disease and those with stage III or IV disease (P < .05). Concurrent validity was established by the good agreement with the FACT-H&N (r = 0.86, P < .001). A highly significant deterioration was in the QOL from the baseline to the end of treatment (mean difference for general tool = 1.95, P < .001; mean difference for H&N subscale = 4.85, P < .001). The Chinese QOL-RTI/H&N is a reliable and valid tool for determining the QOL in H&N cancer patients receiving radiation therapy. The immediate side effects of treatment had a significantly negative impact on the patients' QOL. The impact was relatively large for the functional and treatment-site aspects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare surface electromyography (EMG) activation levels of selected neck muscles for two common neck-training modalities (Thera-Band and Cybex). Seventeen asymptomatic subjects (eight men and nine women) with a mean age 23.4 years were recruited. EMG activation normalized to maximal voluntary isometric contraction (MVIC) was measured with subjects performing exercises with green, blue, and black Thera-Bands and 50%, 70%, and 90% of 3RM for the Cybex modality. Four variables were used to depict exercise intensity: average and peak EMG activation in the concentric and eccentric phases. Significant differences (P <= 0.05) in EMG activation were evident when comparing intensities of the Cybex modality with each other and when comparing the Cybex intensities with Thera-Band intensities in most cases. Minimal differences were found among differing intensities of Thera-Band. Thera-Band exercise resulted in low-level EMG activation (range, flexion 3.8-15.7% MVIC; range, extension 20.2-34.8% MVIC); therefore, such exercise may be useful in rehabilitation programs. Cybex exercise (range, flexion 20.9-83.5% MVIC; range, extension 40.6-95.8% MVIC) may be useful for occupation-related injury prevention. However, exercise prescription should be undertaken with care as the mechanical loading on passive spinal structures is unknown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to examine the reliability of normalisation methods used in the study of the posterior and posterolateral neck muscles in a group of healthy controls. Six asymptomatic male subjects performed a total of 12 maximum voluntary isometric contractions (MVIC) and 60%-submaximal isometric contractions (60%-MVIC) against the torque arm of an isokinetic dynamometer whilst surface and intramuscular electromyography (EMG) was recorded unilaterally from representative posterior and posterolateral locations. Reliability was calculated using intra-class correlation coefficient (ICC), relative standard error of measurement (%SEM) and relative coefficient of variation (%CV). Maximal torque output was found to be highly reliable in the directions of extension and right lateral bending when the first of three MVIC contractions was excluded. When averaged across contraction direction, high reliability was found for both surface (MVIC: ICC = 0.986, %SEM = 7.5, %CV = 9.2; 60%-MVIC: ICC = 0.975, %SEM = 10, %CV = 13.7) and intramuscular (MVIC: ICC = 0.910, %SEM = 20, %CV = 19.1; 60%-MVIC: ICC = 0.952, %SEM = 16.5, %CV = 13.5) electrodes. Intramuscular electrodes displayed the least reliability in right lateral bending. The use of visual feedback markedly increased the reliability of 60%-MVIC contractions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Impairments of cervico-cephalic kinaesthesia and habitual forward head posture have been considered important in the aetiology of postural neck pain, yet these factors have not been specifically examined in a homogeneous clinical population. The objective of this study was to compare the habitual sitting posture (HSP), perception of good posture and postural repositioning error (PRE) of the cervico-thoracic (CT) spine in individuals with postural neck pain, with a matched group of asymptomatic subjects. Twenty-one subjects with postural neck pain and 22 asymptomatic control subjects were recruited into the study. An optical motion analysis system was used to measure the HSP and perceived ‘good’ sitting posture. PRE was measured over six trials where the subject attempted to replicate their self-selected ‘good’ posture. There was no difference between the groups in the HSP but significant differences were identified in the perception of ‘good’ posture. Posture repositioning error was higher for the head posture variables than for CT and shoulder girdle variables in both groups. However, there was no significant difference in posture repositioning error between groups for any of the posture measures. The findings suggest that individuals with postural neck pain may have a different perception of ‘good’ posture, but no significant difference in HSP or kinaesthetic sensibility compared with matched asymptomatic subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Neck injuries are common in high performance combat pilots and have been attributed to high gravitational forces and the non-neutral head postures adopted during aerial combat maneuvers. There is still little known about the pathomechanics of these injuries.

Methods: Six Royal Australian Air Force Hawk pilots flew a sortie that included combinations of three +Gz levels (1, 3, and 5) and four head postures (Neutral, Turn, Extension, and Check-6). Surface electromyography from neck and shoulder muscles was recorded in flight. Three-dimensional measures of head postures adopted in flight were estimated postflight with respect to end-range of the cervical spine using an electromagnetic tracking device.

Results: Mean muscle activation increased significantly with both increasing +Gz and non-neutral head postures. Check-6 at +5 Gz (mean activation of all muscles = 51% MVIC) elicited significantly greater muscle activation in most muscles when compared with Neutral, Extension, and Turn head postures. High levels of muscle co-contraction were evident in high acceleration and non-neutral head postures. Head kinematics showed Check-6 was closest to end-range in any movement plane (86% ROM in rotation) and produced the greatest magnitude of rotation in other planes. Turn and Extension showed a large magnitude of rotation with reference to end-range in the primary plane of motion but displayed smaller rotations in other planes.

Discussion:
High levels of neck muscle activation and co-contraction due to high +Gz and head postures close to end range were evident in this study, suggesting the major influence of these factors on the pathomechanics of neck injuries in high performance combat pilots.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acceptable reliability of normalisation contractions in electromyography (EMG) is paramount for testing conducted over a number of days or if normal laboratory strength testing equipment is unavailable. This study examined the reliability of maximal voluntary isometric contractions (MVIC) and sub-maximal (60%) isometric contractions for use in neck muscle EMG studies. Surface EMG was recorded bilaterally from eight sites around the neck at C4/5 level from five healthy male subjects. Subjects performed MVIC and sub-maximal normalisation contractions using an isokinetic dynamometer (ID) and a portable cable dynamometer with attached strain gauge (PCD) in addition to a MVIC against a manual resistance (MR). Subjects were tested in flexion, extension, left and right lateral bending and were retested by the same tester within a two-week period. Intra class correlation co-efficients (ICC) were calculated for each testing method and contraction direction and a mean ICC was calculated across all contraction directions. All normalisation methods produced excellent within-day reliability (mean ICC >0.80) but only the MVICs using the ID and PCD had acceptable reliability when assessed between-days. This study confirmed the validity of using MVICs elicited using the ID and PCD as reliable reference contractions for the normalisation of neck EMG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Performing specific neck strengthening exercises has been proposed to decrease the incidence of neck injury and pain in high performance combat pilots. However, there is little known about these exercises in comparison to the demands on the neck musculature in flight.

Methods: Eight male non-pilots performed specific neck exercises using two different modalities (elastic band and resistance machine) at six different intensities in flexion, extension, and lateral bending. Six Royal Australian Air Force Hawk pilots flew a sortie that included combinations of three +Gz levels and four head positions. Surface electromyography (EMG) from selected neck and shoulder muscles was recorded in both activities.

Results: Muscle activation levels recorded during the three elastic band exercises were similar to in-flight EMG collected at +1 Gz (15% MVIC). EMG levels elicited during the 50% resistance machine exercises were between the +3 Gz (9-40% MVIC) and +5 Gz (16-53% MVIC) ranges of muscle activations in most muscles. EMG recorded during 70% and 90% resistance machine exercises were generally higher than in-flight EMG at +5 Gz.

Discussion: Elastic band exercises could possibly be useful to pilots who fly low +Gz missions while 50% resistance machine mimicked neck loads experienced by combat pilots flying high +Gz ACM. The 70% and 90% resistance machine intensities are known to optimize maximal strength but should be administered with care because of the unknown spinal loads and diminished muscle force generating capacity after exercise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective : To determine the level of neck strength decrement and the rate of strength recovery of the neck muscles after a single bout of specific neck conditioning exercise in both males and females.

Hypothesis : A decrement in neck strength may be evident after a bout of strengthening exercise.

Design : Intervention study with pre-and-post design.

Setting : Biomechanics laboratory.

Participants : Twenty healthy participants (10 male and 10 female, mean ± standard deviation age 22 ± 1.2 years).

Main Outcome Measures : Participants performed a single bout of neck strengthening exercise. Neck strength testing using an isokinetic dynamometer was performed pre and at five time points (1 h, one, three, five and seven days) post-exercise to assess the level of neck strength decrement and neck strength recovery rate from pre-exercise levels.

Results : Statistically significant (p ≥ 0.036) decreases in neck extension strength were recorded in all participants 1 h and one day post-exercise. The level of neck extension strength returned to pre-exercise levels three days post-exercise and surpassed pre-exercise levels five and seven days post-exercise. The male participants' neck flexion strength decrement and recovery followed a similar pattern to that displayed in neck extension but more variability in neck flexion strength recovery rates were recorded in the female participants in this study.

Conclusion : The consistent strength recovery times for the male participants recorded in this study idealise the prescription of neck strengthening exercises in a periodised fashion. More investigation needs to be instigated for the female neck musculature as consistent strength recovery rates were not identified in this study.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine the relationship between femoral neck geometry and the risk of hip fracture in post-menopausal Caucasian women, we conducted a retrospective study comparing the femoral neck dimensions of 62 hip fracture cases to those of 608 randomly selected controls. Measurements were made from dual-energy X-ray absorptiometry scans (Lunar DPX-L), using the manufacturers ruler function, and included: hip axis length (HAL), femoral neck axis length (FNAL), femoral neck width (FNW), femoral shaft width (FSW), medial femoral shaft cortical thickness (FSCTmed), and lateral femoral shaft cortical thickness (FSCTlat). The fracture group was older (median age 78.3 years vs 73.8 years), lighter (median weight 59.9 kg vs 64.5 kg), and, after adjustment for age, taller (mean height 158.7±0.8 cm vs 156.7±0.2 cm) than the controls. Furthermore, bone mineral density was lower in this group (0.682±0.016 g/cm2 vs 0.791±0.006 g/cm2). After adjustment for age, bone mineral content (BMC) or height, hip fracture patients had greater FNW (up to 6.6%) and FSW (up to 6.3%) than did the controls. Each standard deviation increase in FNW and FSW was associated with a 1.7-fold (95% CI 1.3–2.3) and a 2.4-fold (95% CI 1.8–3.2) increase in the fracture risk, respectively. BMC-adjusted FNAL was greater in the fracture group (+2.1%) than in the controls, while the age-adjusted FSCTmed was reduced (–7.2%). There was a trend towards longer HAL (up to 2.1%) after adjustment for age or BMC, and thinner age-adjusted FSCTlat (–1.7%) in fracture patients that did not reach statistical significance. In multivariate analysis, the risk of hip fracture was predicted by the combination of age, FNW, FSW, BMC and FSCTmed. HAL was not analyzed because of the small number of HAL measurements among fracture cases. We conclude that post-menopausal women with hip fractures have wider femoral necks and shafts, thinner femoral cortices and longer femoral neck axis lengths than do women with no fractures. Alteration in hip geometry is associated with the risk of hip fracture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hip axis length (HAL) has been reported as an independent risk factor for hip fracture. Later puberty may increase bone size because of delayed epiphyseal fusion. We sought to identify associations between bone size at the proximal femur with age at menarche and other indices of growth such as stature. Femoral neck dimensions were measured from dual-energy X-ray absorptiometry scans of the proximal femur in a random sample of 203 premenopausal Caucasian women (age 20–30 years). There were no associations between age at menarche and HAL, femoral axis length (FAL) or femoral neck width (FNW). Age at menarche was associated with height (r= 0.2, p= 0.02). Variations in HAL, FAL and FNW do not appear to be related to age at menarche.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Fighter pilots frequently report neck pain and injury, and although risk factors have been suggested, the relationships between risk factors and neck pain have not been quantified. The aim of this study was to identify personal and work behaviors that are significantly associated with neck pain in fighter pilots.
Methods: Eighty-two Royal Australian Air Force fighter pilots were surveyed about their flying experience, neck pain prevalence, and prevention. Multinomial logistic regressions were used to fit models between pilots' neck pain during and after flight and a range of personal and work characteristics.
Results: In-flight neck pain was very weakly, yet positively associated with flight hours. Duration of postflight pain was positively associated with the weekly desktop work hours and the sum of preventative actions taken in flight. The duration pilots were considered temporarily medically unfit for flying was positively associated with pilots' age and their weekly desktop work hours.
Discussion: The risk factors identified by the current study should guide neck pain prevention for fighter pilots. In particular, reducing desktop working hours as well as incorporating specific neck-strengthening exercises and in-flight bracing actions should be considered by agencies to help alleviating neck pain in their pilots

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RUNX2 is an essential transcription factor required for skeletal development and cartilage formation. Haploinsufficiency of RUNX2 leads to cleidocranial displaysia (CCD) a skeletal disorder characterised by gross dysgenesis of bones particularly those derived from intramembranous bone formation. A notable feature of the RUNX2 protein is the polyglutamine and polyalanine (23Q/17A) domain coded by a repeat sequence. Since none of the known mutations causing CCD characterised to date map in the glutamine repeat region, we hypothesised that Q-repeat mutations may be related to a more subtle bone phenotype. We screened subjects derived from four normal populations for Q-repeat variants. A total of 22 subjects were identified who were heterozygous for a wild type allele and a Q-repeat variant allele: (15Q, 16Q, 18Q and 30Q). Although not every subject had data for all measures, Q-repeat variants had a significant deficit in BMD with an average decrease of 0.7SD measured over 12 BMD-related parameters (p = 0.005). Femoral neck BMD was measured in all subjects (−0.6SD, p = 0.0007). The transactivation function of RUNX2 was determined for 16Q and 30Q alleles using a reporter gene assay. 16Q and 30Q alleles displayed significantly lower transactivation function compared to wild type (23Q). Our analysis has identified novel Q-repeat mutations that occur at a collective frequency of about 0.4%. These mutations significantly alter BMD and display impaired transactivation function, introducing a new class of functionally relevant RUNX2 mutants.