67 resultados para Nearly zero energy buildings

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The era of legislation and creditable methods towards producing sustainable buildings is upon us. Yet, a major barrier to achieving environmental responsive design is in the lack of available information at the programming or pre-design phases of a project. The review and evaluation of climate as well as energy-efficient strategies could be difficult to consider at these preliminary stages. Until recently, introducing energy simulation tools at the design stage has been difficult and perhaps next to impossible at a pre-design or programming stage. However, analysis of this sort is essential to &lsquo;green building rating&rsquo; or performance assessment schemes such as LEED (Leadership in Energy and Environmental Design) and BREEAM (Building Research Establishment Environment Assessment Method). This paper discusses the implementation of a particular tool, ENERGY-10, where &lsquo;basecase&rsquo; building defaults are compared to a low-energy case which has applied multiple energy-efficient strategies automatically. An annual hour-by-hour simulation provides a daylighting calculation with a subsequent thermal evaluation. Calculation results provide energy consumption, peak load equipment sizing, a RANK feature of the energy-efficient strategies, reporting of CO2, SO2 and NOx reduction, optimum glazing type as well as excellent graphic output. Consideration is given as to the approach of how such information can be introduced into the building project brief enforcing a low-energy<br />performance target.<br />

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energy consumption in heating and cooling around the world has been a major contributor to global warming. Hence, many studies have been aimed at finding new techniques to save and control energy through energy efficient measures. Most of this energy is used in residential, agricultural and commercial buildings. It is therefore important to adopt energy efficiency measures in these buildings through new technologies and novel building designs. These new building designs can be developed by employing various passive cooling systems. Earth pipe cooling is one of these which can assist to save energy without using any customary mechanical units. This paper investigates the earth pipe cooling performance in a hot humid subtropical climate of Rockhampton, Australia. A thermal model is developed using ANSYS Fluent for measuring its performance. Impacts of air velocity, air temperature, relative humidity and soil temperature on room cooling performance are also assessed. A temperature reduction of around 2 &deg;C was found for the system. This temperature reduction contributed to an energy saving of a maximum of 866.54 kW (8.82%) per year for a 27.23 m3 room.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two Australian species of teal (Anseriformes: Anatidae: <i>Anas</i>), the grey teal <i>Anas gracilis</i> and the chestnut teal <i>A. castanea</i>, are remarkable for the zero or near-zero divergence recorded between them in earlier surveys of mitochondrial DNA (mtDNA) diversity. We confirmed this result through wider geographical and population sampling as well as nucleotide sampling in the more rapidly evolving mtDNA control region. Any data set where two species share polymorphism as is the case here can be explained by a model of gene flow through hybridization on one hand or by incomplete lineage sorting on the other hand. Ideally, analysis of such shared polymorphism would simultaneously estimate the likelihood of both phenomena. To do this, we used the underlying principle of the IMa package to explore ramifications to understanding population histories of A. gracilis and <i>A. castanea</i>. We cannot reject that hybridization occurs between the two species but an equally or more plausible finding for their nearly zero divergence is incomplete sorting following very recent divergence between the two, probably in the mid-late Pleistocene. Our data add to studies that explore intermediate stages in the evolution of reciprocal monophyly and paraphyletic or polyphyletic relationships in mtDNA diversity among widespread Australian birds.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Embodied energy (EE) analysis has become an important area of energy research, in attempting to trace the direct and indirect energy requirements of products and services throughout their supply chain. Typically, input-output (I-O) models have been used to calculate EE because they are considered to be comprehensive in their analysis. However, a major deficiency of using I-O models is that they have inherent errors and therefore cannot be reliably applied to individual cases. Thus, there is a need for the ability to disaggregate an I-O model into its most important 'energy paths', for the purpose of integrating case-specific data. This paper presents a new hybrid method for conducting EE analyses for individual buildings, which retains the completeness of the I-O model. This new method is demonstrated by application to an Australian residential building. Only 52% of the energy paths derived from the I-O model were substituted using case-specific data. This indicates that previous system boundaries for EE studies of individual residential buildings are less than optimal. It is envisaged that the proposed method will provide construction professionals with more accurate and reliable data for conducting life cycle energy analysis of buildings. Furthermore, by analysing the unmodified energy paths, further data collection can be prioritized effectively. <br />

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Energy used in buildings is a major contributor to Australia&rsquo;s energy consumption and associated environmental impacts. The advent of complex glazing systems such as double glazing, particularly in northern America and Europe, has partially closed a weak thermal link in the building envelope. In milder climates, however, building envelope features may not be as effective in life cycle energy terms, i.e. including the embodied energy of their manufacture. A net energy analysis compares the savings in operational energy to the additional requirements for embodied energy, in terms of the energy payback period and energy return on investment. The effectiveness of double glazing is determined for an Australian residential building. A wide range of building operation regimes was simulated. These results support the principle of installing double glazing in residential buildings in Melbourne, Australia, at least in terms of net primary energy savings.<br />

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aims to compare the energy embodied in office buildings varying in height from a few storeys to over 50 storeys. The energy embodied in substructure, superstructure and finishes elements was investigated for five Melbourne office buildings of the following heights: 3, 7, 15, 42 and 52 storeys. The two high-rise buildings have approximately 60 percent more energy embodied per unit gross floor area (GFA) in their materials than the low-rise buildings. While building height was found to dictate the amount of energy embodied in the &ldquo;structure group&rdquo; elements (upper floors, columns, internal walls, external walls and staircases), other elements such as substructure, roof, windows and finishes seemed uninfluenced.<br />

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We analyse the wood and concrete designs of the W&auml;lludden building described by B&ouml;rjesson et al. (Energy Policy 28 (2000) 575) in terms of their embodied energy, employing an environmentally extended input&ndash;output framework in a tiered hybrid life-cycle assessment, and in a structural path analysis. We illustrate the complexity of the inter-industry supply chains underlying the upstream energy requirements for the building options, and demonstrate that higher-order inputs are difficult to capture in a conventional process analysis. Our calculations show that B&ouml;rjesson and Gustavsson's estimates of energy requirements and greenhouse gas emissions are underestimated by a factor of about 2, and that corresponding greenhouse gas balances are positive at about 30 t C-eq. Nevertheless, B&ouml;rjesson and Gustavsson's general result&mdash;the concrete-framed building causing higher emissions&mdash;still holds.<br />

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Building design decisions are commonly based on issues pertaining to construction cost, and consideration of energy performance is made only within the context of the initial project budget. Even where energy is elevated to more importance, operating energy is seen as the focus and embodied energy is nearly always ignored. For the first time, a large sample of buildings has been assembled and analysed in a single study to improve the understanding of the relationship between energy and cost performance over their full life cycle. Thirty recently completed buildings in Melbourne, Australia have been studied to explore the accuracy of initial embodied energy prediction based on capital cost at various levels of model detail. The embodied energy of projects, elemental groups, elements and selected items of work are correlated against capital cost and the strength of the relationship is computed. The relationship between initial embodied energy and capital cost generally declines as the predictive model assumes more detail, although elemental modelling may provide the best solution on balance. <br />

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a study on energy performance of Singapore's hotel buildings. Energy consumption data and other pertinent information were collected from 29 quality hotels through a national survey. Building features and operational characteristics contributing to the variations in hotel energy performance were discussed. The annual average total energy use intensity (EUI) in these hotels is 427 kWh/m2. Electricity and gas are used in all sampled hotels, and some hotels also use diesel to power standby generator or hot water boiler. We also investigated relationships between electricity consumption and number of occupied rooms in individual hotels; the weak correlations found indicate it is necessary to improve energy management when occupancy rate is low. Besides, Pearson correlations between hotel energy use intensity and possible explanatory indicators revealed that three-star hotels differ from high class establishments in energy use. Worker density and years after the last major energy retrofit were also found to be highly correlated to hotel building energy use intensity. Also discussed in this paper is the effect of weather conditions on electricity consumption of the hotels.<br />

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Buildings have a significant impact on the environment due to the energy required for the manufacture of construction materials. The method of assessing the energy embodied in a product is known as energy analysis. Detailed office building embodied energy case studies are very rare. However, there is evidence to suggest that the energy requirements for the construction phase of commercial buildings, including the energy embodied in materials, is a significant component of the life cycle energy requirements. This thesis sets out to examine the current state of energy analysis, determine the national average energy intensities < i.e. embodied energy rates < for building materials and assess the significance of using national average energy intensities for the energy analysis of a case study office building. Likely ranges of variation in the building material embodied energy rates from the national averages are estimated and the resulting distribution for total embodied energy in the case study building simulated. Strategies for improving the energy analysis methods and data are suggested. Detailed energy analysis is shown to be a useful indicative method of quantifying the energy required for the construction of buildings.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis demonstrates a strong relationship between life cycle energy and life cycle cost based on an analysis of thirty recent Melbourne buildings. Embodied energy (initial cost) can be reliably modelled by construction cost (initial cost) and thus be readily available as early design advice, enabling more sustainable development.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A holistic approach to low-energy building design is essential to ensure that any efficiency improvement strategies provide a net energy benefit over the life of the building. Previous work by the authors has established a model for informing low-energy building design based on a comparison of the life cycle energy demand associated with a broad range of building assemblies. This model ranks assemblies based on their combined initial and recurrent embodied energy and operational energy demand. The current study applies this model to an actual residential building in order to demonstrate the application of the model for optimising a building&rsquo;s life cycle energy performance. The aim of this study was to demonstrate how the availability of comparable energy performance information at the building design stage can be used to better optimise a building&rsquo;s energy performance. The life cycle energy demand of the case study building, located in the temperate climate of Melbourne, Australia, was quantified using a comprehensive embodied energy assessment technique and TRNSYS thermal energy simulation software. The building was then modelled with variations to its external assemblies in an attempt to optimise its life cycle energy performance. The alternative assemblies chosen were those shown through the author&rsquo;s previous modelling to result in the lowest life cycle energy demand for each building element. The best performing assemblies for each of the main external building elements were then combined into a best-case scenario to quantify the potential life cycle energy savings possible compared to the original building. The study showed that significant life cycle energy savings are possible through the modelling of individual building elements for the case study building. While these findings relate to a very specific case, this study demonstrates the application of a model for optimising building life cycle energy performance that may be applied more broadly during early-stage building design to optimise life cycle energy performance.