Patellar tendinopathy, a common condition in sport, can be recurrent and resistant to treatment, Risk factors include the level of training, biomechanics, and genetic factors. This review discusses several programs based on eccentric exercise and suggests principles for nonoperative treatment including improving shock absorption, load modification, and adaptation of the tendon to sporting stress. The level of pain that patients are asked to tolerate during tendon-exercise programs varies among programs, and it is unclear what level is optimal to stimulate tendon recovery. Rehabilitation presents several challenges: It can take a long time (3-12 months), exercise prescription in an athlete who is continuing to compete is not straightforward, and guidelines for treatment progression are poor, Nonoperative treatment can fail because of inappropriate exercise prescription and poor athlete compliance. If this occurs and surgical intervention is required, the athlete might still have an unpredictable outcome. Solutions to these problems require additional clinical research.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: The functional results associated with nonoperative treatment of severely impacted valgus fractures of the proximal part of the humerus are poor, and these injuries are difficult to treat with minimally invasive percutaneous fixation techniques. The aim of this study was to review the functional and radiographic results and complications of a new operative technique in a series of twenty-five patients.

Methods: Over a two-year period, we treated twenty-nine patients with a severely impacted valgus fracture of the proximal part of the humerus. Three patients were lost to follow-up and one died, leaving twenty-five patients who were available for the study. In all of the fractures, the head-shaft angle had been tilted into =160° of valgus and the greater tuberosity was displaced by >1 cm. All patients were treated with open reduction of the fracture, and the space created behind the humeral head was filled with Norian Skeletal Repair System (SRS) bone substitute. The fractures were stabilized with either screws or buttress plate fixation. Associated rotator cuff tears were repaired. All patients underwent functional outcome assessment with use of the Constant, DASH (Disabilities of the Arm, Shoulder and Hand), and SF-36 (Short Form-36) scores at one year, and twelve patients were followed for two years.

Results: All fractures united within the first year, all reductions were maintained, and no patient had signs of osteonecrosis of the humeral head on the latest follow-up radiographs. At one year, the median Constant score was 80 points and the median DASH score was 22 points. The functional results continued to be satisfactory in the twelve patients who were followed for two years. The results in our series were better than those achieved in studies of nonoperative treatment of similar fracture configurations. There were six clinically relevant complications, although none required a reoperation and all six patients had a satisfactory short-term functional outcome.

Conclusions: Internal fixation of severely impacted valgus fractures of the proximal part of the humerus, supplemented by Norian SRS bone substitute to fill the proximal humeral metaphyseal defect, produces good early functional and radiographic outcomes. Additional follow-up will be required to assess whether these initially satisfactory outcomes are maintained over the longer term.

Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background:
The factors influencing the decision making of operative treatment for fractures of the proximal humerus are debated. We hypothesized that there is no difference in treatment recommendations between surgeons shown radiographs alone and those shown radiographs and patient information. Secondarily, we addressed (1) factors associated with a recommendation for operative treatment, (2) factors associated with recommendation for arthroplasty, (3) concordance with the recommendations of the treating surgeons, and (4) factors affecting the inter-rater reliability of treatment recommendations.
Methods: A total of 238 surgeons of the Science of Variation Group rated 40 radiographs of patients with proximal humerus fractures. Participants were randomized to receive information about the patient and mechanism of injury. The response variables included the choice of treatment (operative vs nonoperative) and the percentage of matches with the actual treatment.
Results: Participants who received patient information recommended operative treatment less than those who received no information. The patient information that had the greatest influence on treatment recommendations included age (55%) and fracture me chanism (32%). The only other factor associated with a recommendation for operative treatment was region of practice. There was no significant difference between participants who were and were not provided with information regarding agreement with the actual treatment (operative vs nonoperative) provided by the treating surgeon.
Conclusion: Patient information - older age in particular - is associated with a higher likelihood of recommending nonoperative treatment than radiographs alone. Clinical information did not improve agreement of the Science of Variation Group with the actual treatment or the generally poor interobserver agreement on treatment recommendations

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The functional results associated with nonoperative treatment of severely impacted valgus fractures of the proximal part of the humerus are poor, and these injuries are difficult to treat with minimally invasive percutaneous fixation techniques. The aim of this study was to review the functional and radiographic results and complications of a new operative technique in a series of twenty-five patients.

Methods: Over a two-year period, we treated twenty-nine patients with a severely impacted valgus fracture of the proximal part of the humerus. Three patients were lost to follow-up and one died, leaving twenty-five patients who were available for the study. In all of the fractures, the head-shaft angle had been tilted into > or = 160 degrees of valgus and the greater tuberosity was displaced by >1 cm. All patients were treated with open reduction of the fracture, and the space created behind the humeral head was filled with Norian Skeletal Repair System (SRS) bone substitute. The fractures were stabilized with either screws or buttress plate fixation. Associated rotator cuff tears were repaired. All patients underwent functional outcome assessment with use of the Constant, DASH (Disabilities of the Arm, Shoulder and Hand), and SF-36 (Short Form-36) scores at one year, and twelve patients were followed for two years.

Results: All fractures united within the first year, all reductions were maintained, and no patient had signs of osteonecrosis of the humeral head on the latest follow-up radiographs. At one year, the median Constant score was 80 points and the median DASH score was 22 points. The functional results continued to be satisfactory in the twelve patients who were followed for two years. The results in our series were better than those achieved in studies of nonoperative treatment of similar fracture configurations. There were six clinically relevant complications, although none required a reoperation and all six patients had a satisfactory short-term functional outcome.

Conclusions: Internal fixation of severely impacted valgus fractures of the proximal part of the humerus, supplemented by Norian SRS bone substitute to fill the proximal humeral metaphyseal defect, produces good early functional and radiographic outcomes. Additional follow-up will be required to assess whether these initially satisfactory outcomes are maintained over the longer term.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to review the complication rate and profile associated with surgical fixation of acute midshaft clavicle fracture in a large cohort of patients treated in a level I trauma centre.Patients and methods: We identified all patients who underwent surgical treatment of acute midshaft clavicle fracture between 2002 and 2010. The study group consisted of 138 fractures (134 patients). There were 107 males (78%) and 31 females (22%) and median age of 35 years (IQR 24-45). The most common mechanism of injury was a road traffic accident (78%). Sixty percent (n = 83) had an injury severity score of ≥ 15 indicating major trauma. The most common fracture type (75%) was simple or wedge comminuted (2B1) according to the Edinburgh classification. The median interval between the injury and operation was 3 days (IQR 1-6). Plate fixation was performed in 110 fractures (80%) and intramedullary fixation was performed in 28 fractures (20%). There were 85 males and 25 females in the plate fixation group with median age of 35 years (IQR: 25-45) There were 22 males and 6 females in intramedullary fixation group with median age of 31 years (IQR 24-42 years). Statistical analysis was performed using Independent sample t-test, Mann-Whitney test, and Chi-square test. Significant P-value was < 0.05.Results: The overall incidence of complication was 14.5% (n = 20). The overall nonunion rate 6%. Post operative wound infection occurred in 3.6% of cases. The incidence of complication associated with plate fixation was 10% (11 of 110 cases) compared to 32% associated with intramedullary fixation (9 of 28 cases) (P = 0.003). Thirty five percent of complications were related to inadequate surgical technique and potentially avoidable. Symptomatic hardware requiring removal occurred in 23% (n = 31) of patients. Symptomatic metalware was more frequent after plate fixation compared to intramedullary fixation (26% vs 7%, P = 0.03).Conclusions: Intramedullary fixation of midshaft clavicle fracture is associated with higher incidence of complications. Plate fixation is associated with a higher rate of symptomatic metalware requiring removal compared to intramedullary fixation. Approximately one in three complications may be avoided by attention to adequate surgical technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose To address the null hypothesis that surgeons shown radiographs of little finger metacarpal neck fractures with measured fracture angulation would recommend surgery as often as surgeons shown unmarked radiographs. Methods Members of the Science of Variation Group, an international collaboration of fully trained orthopedic and trauma surgeons, were asked to review 20 little finger metacarpal neck fracture cases, which included a vignette and 3 high-quality radiographs. Members were then randomized to review radiographs with or without measured fracture angulation on the lateral view and select operative or nonoperative management. Results Surgeons shown radiographs with measured angulation were more likely to recommend surgery, and there was less variability among these surgeons, particularly for fractures with less angular deformity. Conclusions Measured fracture angulation has a small but significant influence on treatment recommendations for little finger metacarpal neck fractures.