53 resultados para Microsoft Office

em Deakin Research Online - Australia


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper centres around the presentation of multiple measured results on a psychrometric chart. The psychrometric chart was programmed in Microsoft Office Excel to accommodate measured results. It was written because existing programs appear not to cater for the researcher wishing to enter results electronically onto the chart. Furthermore, many existing charts are complex and cluttered displaying up to ten attributes, being intended for engineering design, whereas presenting the behaviour of living and working environments is focused on wet and dry bulb temperature and relative humidity. As well as results, users would also like to specify and adjust the ‘comfort zone’ (a shaded area on the chart) for different ‘adaptive’ or ‘seasonal’ conditions. The comfort zone is bounded by lines of constant heat loss from the skin, relative humidity and wet-bulb temperature. The paper presents various applications of the psychrometric chart for the analysis and reporting of research and discusses the programming of Microsoft Office Excel to generate the chart and display user data.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Data is a collation of local and global programs that address tertiary education attainment. It is in the form of a Microsoft Office Excel spreadsheet and is purely text.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims to compare the energy embodied in office buildings varying in height from a few storeys to over 50 storeys. The energy embodied in substructure, superstructure and finishes elements was investigated for five Melbourne office buildings of the following heights: 3, 7, 15, 42 and 52 storeys. The two high-rise buildings have approximately 60 percent more energy embodied per unit gross floor area (GFA) in their materials than the low-rise buildings. While building height was found to dictate the amount of energy embodied in the “structure group” elements (upper floors, columns, internal walls, external walls and staircases), other elements such as substructure, roof, windows and finishes seemed uninfluenced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In exploiting the capabilities of online technologies, governments have developed policies and launched projects to conduct transactions and deliver their services through the Internet. The motivations for this include cost cutting, efficiency improvements, service enhancements, and leadership in business transformation. However, these diverse goals are not necessarily consistent, especially in the early stages of implementation. The e-government initiative discussed in this case study (E-Tax) provided an additional service to individual Australian taxpayers by enabling them to file their tax returns online. This case study provides an analysis of the E-Tax implementation in the first three years of its operation. Data on E-Tax use compared to other filing methods show that the package worked well technically, was favorably received by users, and was consistent with policy on e-government. However, adoption levels in the early stages did not meet government targets. The analysis suggests that impediments to a greater level of E-Tax use included entrenched patterns of filing, the nature of the taxation system, and political sensitivities. The E-Tax case demonstrates how complex e-government projects can be and the need to take contextual factors into account in planning and evaluating e-government implementation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy efficient office buildings are intended to provide a comfortable and healthy environment for their occupants as well as reducing the energy consumption of the building. They are often designed as "showcase" buildings illustrating the potential for savings through some innovative design technology. But do such buildings actually deliver the desired energy savings and satisfactory comfort conditions for occupants? Measurements of a "green" University campus building in Victoria, Australia, designed with an innovative fabric energy storage system, demonstrate that the ventilation system is not providing acceptable indoor air quality conditions. The design strategies used to reduce energy consumption have had negative consequences on the air quality of the building. Insufficient fresh air is being drawn into the building leading to an excessive build up of carbon dioxide. It is recommended that monitoring systems need to use a wider range of measurements than temperature alone to guarantee good quality indoor air and working conditions and that commissioning of buildings should include adequate monitoring of the operational performance of the building. Designers need to be made aware of the potential consequences of their decisions when attempting innovative energy-efficient designs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A recently-published work in by two well-known authors in the field of spreadsheet modeling is reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an application of Microsoft Robotics Studio (MSRS) in which a team of six four wheel drive, ground based robots explore and map simulated terrain. The user has the ability to modify the terrain and assign destination objectives to the team while the simulation is running. The terrain is initially generated using a gray scale image, in which the intensity of each pixel in the image gives an altitude datum. The robots start with no knowledge of their surroundings, and map the terrain as they attempt to reach user-defined target objectives. The mapping process simulates the use of common sensory hardware to determine datum points, including provision for field of view, detection range, and measurement accuracy. If traversal of a mapped area is indicated by the users’ targeting commands, path planning heuristics developed for MSRS by the author in earlier work are used to determine an efficient series of waypoints to reach the objective. Mutability of terrain is also explored- the user is able to modify the terrain without stopping the simulation. This forces the robots to adapt to changing environmental conditions, and permits analysis of the robustness of mapping algorithms used when faced with a changing world.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A two-storey rammed earth building was built on the Thurgoona Campus of Charles Sturt University in Albury-Wodonga, Australia, in 1999. The building is novel both in the use of materials and equipment for heating and cooling. The climate at Wodonga can be characterised as hot and dry, so the challenge of providing comfortable working conditions with minimal energy consumption is considerable. This paper describes an evaluation of the building in terms of measured thermal comfort and energy use. Measurements, confirmed by a staff questionnaire, found the building was too hot in summer and too cold in winter. Comparison with another office building in the same location found that the rammed earth building used more energy for heating. The thermal performance of three offices in the rammed earth building was investigated further using simulation to predict office temperatures. Comparisons were made with measurements made over typical weeks in summer and winter. The validated model has been used to investigate key building parameters and strategies to improve the thermal comfort and reduce energy consumption in the building. Simulations showed that improvements could be made by design and control strategy changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research is a preliminary investigation of the objective measurements ofthelmal comfort and C02 levels as well as subjective user evaluation surveys in six meeting rooms. The ongoing objective measurements were taken via thelmal comfort carts while the surveys evaluated parameters of temperature, lighting, air quality, meeting effectiveness etc. The outcomes are of particular interest since some of the objective measurements clearly to not support those of the users. In fact, the investigation has triggered off further interest in refining questionnaires to develop more precise indicators of 'discomfort'.
Furthelmore, meeting rooms present a challenge when it comes to conditioning spaces (HV AC design) which are sporadic in use and often with high occupancy for short periods. This paper investigates meeting rooms in four different buildings and their conditioning control concepts are discussed in relation to measured results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of climate change and global warming has received increased attention in society with constant reminders about the importance of energy efficiency and sustainability in buildings. Whilst the focus is often placed on smaller items such as plastic bags, air conditioners and motor vehicles, the emphasis has recently shifted to structures in the built environment. Office buildings have been identified as contributing significantly to global warming during their building lifecycle with a substantial contribution to CO2 omissions. In response, building designs and construction techniques have evolved over time to improve energy efficiency and reduce CO2 omissions. Whilst property valuers, managers and analysts must remain up-to-date regarding changes, relatively little research has been conducted about whether and how increased sustainability, such as signified in a Green Star rating affects a property’s highest and best value and long-term lifecycle. This study investigates the degree to which sustainability is understood in the property marketplace, especially in relation to property values with the emphasis placed on a cost- benefit analysis from both an owner’s and tenant’s perspective. Whilst it may be argued that incorporating sustainability into a new office building is cost prohibitive on a financial cost-benefit analysis, often various minor steps can be taken to upgrade the sustainability of an existing building. This project examines recent trends in capital expenditure to increase the sustainability of offices and where Green Star ratings have been applied to establish whether any corresponding increase in value is evident. In order to develop a researchframework, a thorough literature review will be conducted of recent Australian and overseas studies. This will enable links between sustainability and office buildings to be highlighted, and vitally how they affect a property’s value in both the short and long-term.