45 resultados para Maximal arc

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses the personal perceptions that have shaped my poetics in writing La Pucelle: an Epic of Joan of Arc as part of a PhD candidature in the School of Communication and Creative Arts, Deakin University.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of pacing on performance, oxygen uptake (V̇O2), oxygen deficit and blood lactate accumulation during a 6-minute cycle ergometer test. Six recreational cyclists completed three 6-minute cycling tests using fast-start, even-pacing and slow-fast pacing conditions. Cycle ergometer performance was measured as the mean power output produced for each cycling test. Energy system contribution during each cycling trial was estimated using a modified accumulated oxygen deficit (AOD) method. Blood lactate concentration was analysed from blood sampled using a catheter in a forearm vein prior to exercise, at 2 minutes, 4 minutes and 6 minutes during exercise, and at 2 minutes, 5 minutes and 10 minutes post-exercise. There was no significant difference between the pacing conditions for mean power output (P=0.09), peak V̇O2 (P=0.92), total V̇O2 (P=0.76), AOD (P=0.91), the time-course of V̇O2 (P=0.22) or blood lactate accumulation (P=0.07). There was, however, a significant difference between the three pacing conditions in the oxygen deficit measured over time (P=0.02). These changes in the time-course of oxygen deficit during cycling trials did not, however, significantly affect the mean power output produced by each pacing condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are 3 distinct yet closely integrated processes that operate together to satisfy the energy requirements of muscle. The anaerobic energy system is divided into alactic and lactic components, referring to the processes  involved in the splitting of the stored phosphagens, ATP and  phosphocreatine (PCr), and the nonaerobic breakdown of carbohydrate to lactic acid through glycolysis. The aerobic energy system refers to the combustion of carbohydrates and fats in the presence of oxygen. The anaerobic pathways are capable of regenerating ATP at high rates yet are limited by the amount of energy that can be released in a single bout of intense exercise. In contrast, the aerobic system has an enormous capacity yet is somewhat hampered in its ability to delivery energy quickly. The focus of this review is on the interaction and relative contribution of the energy systems during single bouts of maximal exercise. A particular emphasis has been placed on the role of the aerobic energy system during high intensity exercise.

Attempts to depict the interaction and relative contribution of the energy systems during maximal exercise first appeared in the 1960s and 1970s. While insightful at the time, these representations were based on calculations of anaerobic energy release that now appear questionable. Given repeated reproduction over the years, these early attempts have lead to 2 common misconceptions in the exercise science and coaching professions. First, that the energy systems respond to the demands of intense exercise in an almost sequential manner, and secondly, that the aerobic system responds slowly to these energy demands, thereby playing little role in determining performance over short durations. More recent research suggests that energy is derived from each of the energy-producing pathways during almost all exercise activities. The duration of maximal exercise at which equal contributions are derived from the anaerobic and aerobic energy systems appears to occur between 1 to 2 minutes and most probably around 75 seconds, a time that is considerably earlier than has traditionally been suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To efficiently and yet accurately cluster Web documents is of great interests to Web users and is a key component of the searching accuracy of a Web search engine. To achieve this, this paper introduces a new approach for the clustering of Web documents, which is called maximal frequent itemset (MFI) approach. Iterative clustering algorithms, such as K-means and expectation-maximization (EM), are sensitive to their initial conditions. MFI approach firstly locates the center points of high density clusters precisely. These center points then are used as initial points for the K-means algorithm. Our experimental results tested on 3 Web document sets show that our MFI approach outperforms the other methods we compared in most cases, particularly in the case of large number of categories in Web document sets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: This study investigated the effects of endurance training status and sex differences on skeletal muscle Na+,K+-pump mRNA expression, content and activity. Methods: Forty-five endurance-trained males (ETM), 11 recreationally active males (RAM), and nine recreationally active females (RAF) underwent a vastus lateralis muscle biopsy. Muscle was analysed for Na+,K+-pump α1, α2, α3, β1, β2 and β3 isoform mRNA expression (real-time reverse transcription-polymerase chain reaction), content ([3H]-ouabain-binding site) and maximal activity (3-O-methylfluorescein phosphatase, 3-O-MFPase). Results: ETM demonstrated lower α1, α3, β2 and β3 mRNA expression by 74%, 62%, 70% and 82%, respectively, than RAM (P < 0.04). In contrast, [3H]-ouabain binding and 3-O-MFPase activity were each higher in ETM than in RAM, by 16% (P < 0.03). RAM demonstrated a 230% and 364% higher α3 and b3 mRNA expression than RAF, respectively (P < 0.05), but no significant sex differences were found for α1, α2, β1 or β2 mRNA, [3H]-ouabain binding  or 3-O-MFPase activity. No significant correlation was found between years of endurance training and either [3H]-ouabain binding or 3-O-MFPase activity. Significant but weak correlations were found between the number of training hours per week and 3-O-MFPase activity (r = 0.31, P < 0.02) and between incremental exercise V O2(peak) and both   [3H]-ouabain binding (r = 0.33, P < 0.01) and 3-O-MFPase activity (r = 0.28, P < 0.03). Conclusions: Isoform-specific differences in Na+,K+-pump mRNA expression were found with both training status and sex differences, but only training status influenced Na+,K+-pump content and maximal activity in human skeletal muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physical vapour deposition (PVD) titanium aluminium nitride coated cutting tools are used extensively in global manufacturing for reducing production costs and improving productivity in a number of aggressive metal-cutting operations, namely, dry and high-speed machining. In this investigation, the performance of Ti1−xAlxN and Ti1−x−yAlxCryN coatings was assessed on Co-HSS twist drills used to machine grey cast iron. The failure criterion for drills was defined as a critical sized flank wear land at the outer corners of the drills. Using this criterion, the average tool life of uncoated twist drills was increased by factors of 2.5, 3.0 and 3.0 by Ti0.59Al0.41N, Ti0.27Al0.19Cr0.54N and Ti0.21Al0.14Cr0.65N coatings, respectively. Notwithstanding the similar increase in average tool life, the Ti1−x−yAlxCryN coatings produced more consistent results than the Ti1−xAlxN coated drills with standard deviations of 67, 3 and 19 holes, respectively. This result has significant practical implications in manufacturing, since drills are not replaced on an individual basis, but rather on a preset tool change frequency. The present paper discusses the performance of Ti1−xAlxN and Ti1−x−yAlxCryN coated drills in terms of average and practical drill life and concludes with remarks on the characterisation of PVD coatings and their significance on the performance of Co-HSS twist drills when dry machining grey cast iron.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cathodic arc evaporation (CAE) is a widely used technique for generating highly ionised plasma from which hard, wear-resistant PVD coatings can be deposited. A major drawback of this technique is the emission of micrometer-sized droplets of cathode material from the arc spot, which are commonly referred to as ‘macroparticles’. In this study, the effect of cathode poisoning was investigated as a method to reduce the number of macroparticles in PVD coatings. While the study focuses on the reduction of macroparticles in titanium nitride coatings, the outcomes and key findings can be broadly applied to the cathodic arc process, in particular, for the reduction of macroparticles in more advanced CAE coatings. The results support earlier findings that have shown that poisoning of the cathode can reduce the number of macroparticles emitted from the arc spot. The results of glow discharge optical emission spectroscopy (GD-OES) showed that the titanium content of the coatings varied little between the respective coatings despite changes in the deposition pressure from 0.1 to 1.2 Pa. The GD-OES results also showed the presence of oxide contamination at the surface of the coatings, which was significantly reduced with increasing deposition pressure. The coatings were also deposited onto high-speed steel twist drills to compare the metal-cutting performance when dry drilling a workpiece of cast iron. The results of the drill tests showed that tool life increased with a reduction in the number of macroparticles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Athletes commonly attempt to enhance performance by training in normoxia but sleeping in hypoxia [live high and train low (LHTL)]. However, chronic hypoxia reduces muscle Na+-K+-ATPase content, whereas fatiguing contractions reduce Na+-K+-ATPase activity, which each may impair performance. We examined whether LHTL and intense exercise would decrease muscle Na+-K+-ATPase activity and whether these effects would be additive and sufficient to impair performance or plasma K+ regulation. Thirteen subjects were randomly assigned to two fitness-matched groups, LHTL (n = 6) or control (Con, n = 7). LHTL slept at simulated moderate altitude (3,000 m, inspired O2 fraction = 15.48%) for 23 nights and lived and trained by day under normoxic conditions in Canberra (altitude ~600 m). Con lived, trained, and slept in normoxia. A standardized incremental exercise test was conducted before and after LHTL. A vastus lateralis muscle biopsy was taken at rest and after exercise, before and after LHTL or Con, and analyzed for maximal Na+-K+-ATPase activity [K+-stimulated 3-O-methylfluorescein phosphatase (3-O-MFPase)] and Na+-K+-ATPase content ([3H]ouabain binding sites). 3-O-MFPase activity was decreased by –2.9 ± 2.6% in LHTL (P < 0.05) and was depressed immediately after exercise (P < 0.05) similarly in Con and LHTL (–13.0 ± 3.2 and –11.8 ± 1.5%, respectively). Plasma K+ concentration during exercise was unchanged by LHTL; [3H]ouabain binding was unchanged with LHTL or exercise. Peak oxygen consumption was reduced in LHTL (P < 0.05) but not in Con, whereas exercise work was unchanged in either group. Thus LHTL had a minor effect on, and incremental exercise reduced, Na+-K+-ATPase activity. However, the small LHTL-induced depression of 3-O-MFPase activity was insufficient to adversely affect either K+ regulation or total work performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ti–49.5 at%Ni thin films have been formed by deposition onto Si and glass substrates using a filtered arc deposition system (FADS). The films deposited on glass were composed of nanocrystalline parent phase grains contained within an amorphous matrix. The films deposited onto silicon were crystalline, and were largely parent phase whereas a bulk alloy of the same composition would be expected to be martensite. The stabilisation of the parent phase is proposed to be a grain size effect, with the critical grain size for parent phase stabilisation being about 30 nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare three calculation methods to determine the load that maximises power output in the power clean. Five male athletes (height=179.8 10.5cms, weight 91 .8 8.8kg, power dean 1RM = 117.0 20.5kg) performed two per cleans at 10% increments from 50% to 100% of 1RM. Bar displacement data was collected using a Ballistic Measurement System (BMS) and vertical ground reaction force (VGRF) data was measured by a Kistler 9287B Force Plate. Power output was calculated for BMS (system mass), BMS (bar mass) and VGRF/BMS system mass. Optimal load was determined to be 70% for the BMS (system mass) and VGRF BMS (system mass) methods and 90% for the BMS (bar mass) method. Sports scientists should be aware of the technical issues underlying these findings due to the practical ramifications for athlete testing and training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The influence of water immersion on neuromuscular function is of importance to a number of disciplines; however, the reliability of surface electromyography (SEMG) following water immersion is not known. This study examined the reliability of SEMG amplitude during maximal voluntary isometric contractions (MVICs) of the vastus lateralis following water immersion.

Methods: Using a Biodex isokinetic dynamometer and in a randomized order, 12 healthy male subjects performed four MVICs at 60° knee flexion on both the dominant and nondominant kicking legs, and the SEMG was recorded. Each subject's dominant and nondominant kicking leg was then randomly assigned to have SEMG electrodes removed or covered during 15 min of water immersion (20°C–25°C). Following water immersion, subjects performed a further four MVICs.

Results: Intraclass correlation coefficient (ICC) and the relative standard error of measurement (%SEM) of SEMG amplitude showed moderate to high trial-to-trial reliability when electrodes were covered (0.93% and 2.79%) and removed (0.95% and 2.10%, respectively).

Conclusions: The results of the this study indicate that SEMG amplitude of the vastus lateralis may be accurately determined during maximal voluntary contractions following water immersion if electrodes are either removed or covered with water-resistive tape during the immersion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The VO2-power regression and estimated total energy demand for a 6-minute supramaximal exercise test was predicted from a continuous incremental exercise test. Sub-maximal VO2- power co-ordinates were established from the last 40 seconds(s) of 150-second exercise stages. The precision of the estimated total energy demand was determined using the 95% confidence interval (95% CI) of the estimated total energy demand. The linearity of the individual VO2-power regression equations was determined using Pearson's correlation coefficient. The mean 95% CI of the estimated total energy demand was 5.9±2.5 mL O2 Eq•-1kg•min-1, and the mean correlation coefficient was 0.9942±0.0042. The current study contends that the sub-maximal VO2-power co-ordinates from a continuous incremental exercise test can be used to estimate supra-maximal energy demand without compromising the precision of the accumulated oxygen deficit (AOD) method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thesis comprising a creative component in the form of an epic about the history of Joan of Arc and an exegetical component concerned with redefining the epic genre and exploring the author's project.