15 resultados para MAPPING NONUNIFORM CORROSION

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

 A new method has been developed to measure metal corrosion rates and their distribution under cathodic protection (CP). This method uses an electrochemically integrated multi-electrode array to take local measurements of cathodic current density while simulating a continuous metallic surface. The distribution of cathodic current densities obtained under CP was analyzed to estimate the anodic current component at each electrode of the array. Corrosion patterns determined by this new method have shown good correlation with visual inspection and surface profilometry of the multi-electrode array surface.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A new method of visualising dynamically changing electrode processes has been demonstrated by mapping localised corrosion processes occurring on buried steel surfaces under the effect of anodic transients. Dynamically shifting external electrical interferences such as anodic transients are known to affect the efficiency of cathodic protection (CP) of underground pipelines; however unfortunately conventional techniques including electrochemical methods have difficulties in measuring such effects. In this paper we report that the wire beam electrode has necessary temporal and spatial resolutions required for measuring and visualising the dynamic effects of anodic transients on CP, passivation and localised corrosion processes occurring on buried steel surfaces. For the first time a critical anodic transient duration has been observed and explained as the incubation period for the breakdown of passivity and the initiation of localised corrosion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

New progresses have been made during recent years in the application of the wire beam electrode (WBE, a coupled multielectrode array) for studying electroplating of metallic coatings, for monitoring the electrodeposition of polymer coatings, and for evaluating the performance of anti-corrosion coatings. The WBE allows localized electrode processes to occur over different locations of its surface under external anodic or cathodic polarization and permits monitoring of nonuniform electrodeposition processes. Several typical experiments are presented in this paper. One sample experiment is the characterization of nonuniform electroplating of nickel coating, which was achieved by mapping the distributions of currents over a WBE surface that was under cathodic polarization. Various characteristic current distribution patterns, which indicate different electrodeposition mechanisms or low covering-power, have been observed. These patterns were found to correlate with the effects of several affecting factors such as electrolyte concentration, temperature and agitation flow. Another sample experiment is the investigation of nonuniform anodic electrodeposition of polyaniline (PANI) coatings and the understanding of their anti-corrosion performance and mechanisms. Anodic polarization currents were measured from various locations over the WBE surface in order to produce anodic polarization current maps under PANI deposition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mixed rare-earth organophosphates have been investigated as potential corrosion inhibitors for AA2024-T3, and previously have shown synergistic inhibition behavior; however, the mechanism was not identified. In this paper, a key factor contributing to corrosion inhibition of AA2024-T3 with mischmetal diphenyl phosphate [Mm(dpp)3] is the unique stability of Pr(dpp)3 compared to other key rare earths in mischmetal. Although increasing pH causes precipitation of other components, the Pr compound is stable at higher pH. Electrochemically, a synergy is evident when Ce(dpp)3 and Pr(dpp)3 are combined. Raman mapping indicates the Pr(dpp)3 inhibitor leads to a more uniform coverage of the alloy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An auto-switch device has been designed, constructed, and tested for multisensor corrosion measurements. The auto-switch is able to connect/disconnect the selected wire beam electrode and/or electrode pairs under computer control. A computer controlled analog switch-array consisting of 100 inputs has been used as an essential part of the switch bank. The switch-bank is an essential component of a corrosion-monitoring instrument that is expected to find wide application in industry. The performance of the switch-bank is discussed and its effect on the signals is illustrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This book covers the areas of electrochemical heterogeneity and electrode inhomogeneity and their effects on nonuniform electrode processes, in particular, localized corrosion. It covers the fundamentals, experimental methods, and engineering aspects of electrochemical heterogeneity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several new technical developments have been made based on the combined use of the wire beam electrode (WBE), electrochemical noise analysis (ENA) and the scanning reference electrode technique (SRET). These have included: (i) The WBE-R n method- the combined use of the WBE and the noise resistance (Rn) to map the rates and patterns of uniform or localized corrosion; (ii) The WBE-Noise Signatures method- the combined use of the WBE and the noise signature to detect the origination and propagation of localized corrosion; and (iii) The WBE-SRET method- the combined use of the WBE and SRET to investigate localized corrosion from both the metallic and electrolyte phases of a corroding metal surface. This paper presents a brief review on these novel methods and their applications for detecting general and localized corrosion, for mapping the rates of corrosion, and for studying corrosion inhibitors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Different modes of scanning electrochemical mapping (SECM) such as surface generation/tip collection (SG/TC), amperometry, AC-SECM and potentiometry were employed to characterize the active/passive domains, hydrogen gas (H2) evolution and local pH on a corroding surface of AZ31 in simulated biological fluid (SBF). It was found that the main domains of H2 evolution are associated with lower insulating properties of the surface as well as higher local pH. The near surface pH was found to be highly alkaline indicating that, even in a buffered solution such as SBF, the local pH on a corroding AZ31 surface can be significantly different to the bulk pH. © 2014 Elsevier Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Surface passivation of AZNd Mg alloy with Pr(NO3)3 is studied using scanning electrochemical microscopy (SECM) in surface generation/tip collection (SG/TC) and AC modes. Corrosion protection afforded by the Pr treatment and the degradation mechanism in a simulated biological environment was examined on a local scale and compared with non-treated AZNd. SG/TC mode results revealed a drastic decrease in H2 evolution due to the Pr treatment. Mapping the local insulating characteristics using AC-SECM showed higher conductivity of the surface where H2 evolution was most favorable.