7 resultados para Infra-ordinaire

em Deakin Research Online - Australia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Continuous measurement of internal and external environmental parameters is critical to our understanding of how buildings perform. Yet, the quantity and variety of time-series data can be quite overwhelming as well as onerous to decipher and present. In addition to this, is the fact that several of the collected data are useless in their raw format unless processed through algorithms to obtain identifiable and meaningful results.
These circumstances challenge the conventional way we present accumulated data and their processed outputs in order to get a better understanding of how and why the environmental performance occurred. It would be ideal if all of the collected and processed data could be presented in a simultaneous, yet, useful format. It is exactly the intention of this paper to suggest and present such a process as well as its format.
An example case study is provided where several parameters (air velocity, mean radiant temperature, humidity and air temperature) are measured periodically to calculate a time-series of internal comfort performance. However, external conditions of solar radiation and solar position as well as air temperature drive the interior building surface temperatures and help to explain the end result of internal comfort.
A program has been written to present the various sets of data graphically, in an integrated manner, animated as a function of time. The animation shows solar position, a cursor scanning weather data, the changing infra-red image and a representation of the resulting internal comfort performance throughout the
monitored period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current study assessed the intra- and inter-day reliability of a custom-built gymnastics vaulting feedback system. The system is a coach-friendly customized infra-red timing gate and contact timing mat system operated by the coach to augment the feedback provided to gymnasts on their vaulting performance during regular training practice. Thirteen Australian high performance gymnasts (eight males and five females) aged 11-23 years were assessed during two training sessions (Day 1 and Day 2) at their regular training centre. The approach velocity and board contact time measures were found to be reliable measures during vault training, with measures of pre-flight and table contact time less consistent. Future research should examine the validity of these measures as a tool for monitoring vault training.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inter-day training reliability and variability in artistic gymnastics vaulting was determined using a customised infra-red timing gate and contact mat timing system. Thirteen Australian high performance gymnasts (eight males and five females) aged 11-23 years were assessed during two consecutive days of normal training. Each gymnast completed a number of vault repetitions per daily session. Inter-day variability of vault run-up velocities (at -18 to -12 m, -12 to -6 m, -6 to -2 m, and -2 to 0 m from the nearest edge of the beat board), and board contact, pre-flight, and table contact times were determined using mixed modelling statistics to account for random (within-subject variability) and fixed effects (gender, number of subjects, number of trials). The difference in the mean (Mdiff) and Cohen's effect sizes for reliability assessment and intra-class correlation coefficients, and the coefficient of variation percentage (CV%) were calculated for variability assessment. Approach velocity (-18 to -2 m, CV = 2.4-7.8%) and board contact time (CV = 3.5%) were less variable measures when accounting for day-to-day performance differences, than pre-flight time (CV = 17.7%) and table contact time (CV = 20.5%). While pre-flight and table contact times are relevant training measures, approach velocity and board contact time are more reliable when quantifying vaulting performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the direct electro-chemical reduction of graphene oxide to graphene from aqueous suspension by applying reduction voltages exceeding -1.0 to -1.2 V. The conductivity of the deposition medium is of crucial importance and only values between 4-25 mS cm-1 result in deposition. Above 25 mS cm-1 the suspension de-stabilises while conductivities below 4 mS cm-1 do not show a measurable deposition rate. Furthermore, we show that deposition can be carried out over a wide pH region ranging from 1.5 to 12.5. The electro-deposition process is characterised in terms of electro-chemical methods including cyclic voltammetry, quartz crystal microbalance, impedance spectroscopy, constant amperometry and potentiometric titrations, while the deposits are analysed via Raman spectroscopy, infra-red spectroscopy, X-ray photoelectron spectroscopy and X-ray diffractometry. The determined oxygen contents are similar to those of chemically reduced graphene oxide, and the conductivity of the deposits was found to be ~20 S cm -1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The feasibility of cassava peel waste for Ni-sorption is evaluated in this work. The biosorbents are characterized by Boehm titration, Fourier transform-infra red (FTIR) spectroscopy, Nitrogen sorption, scanning electron microscopy-energy dispersive X-ray (SEM-EDX) analysis (e.g. elemental mapping) and X-ray photoelectron spectroscopy (XPS). Adsorption experiments are performed in batch mode at 30 °C (303.15 K), 45 °C (318.15 K) and 60 °C (333.15 K). The performance of several temperature dependence forms of isotherm models e.g. Langmuir, Freundlich, Sips and Toth to represent the adsorption equilibrium data is evaluated and contrasted. Sips model demonstrates the best fitting with the maximum uptake capacity for Ni(II) ions of 57 mg/g (0.971 mmol/g) at pH 4.5. For kinetic data correlation, pseudo-second order model shows the best representation. The chemisorption mechanism and thermodynamics aspect are also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Heat-reflective layered apparel or footwear constructed from various combinations of layers of materials having selected thermal and moisture transfer properties to provide improved performance characteristics. Within these various combinations, the addition of a very thin heat reflective layer, made with a metallic material such as aluminum, applied using a vacuum plasma vapor deposition method, provides a coating that will reflect infra red heat energy either back to the body or away from the body. This heat reflective coating is so thin that is does not adversely alter the original suppporting fabrics hand feel, drape,weight , strectch or breathability. Various layers manage the body heat of an individual by reflection or thermal retention while also providing moisture wicking and antimicrobial function. Other layers manage thermal isolation from the external temperatures by using materials with very low thermal conductivity in combination with waterproof layers that can also be breathable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a method using attenuated total reflectance infra-red spectroscopy to determine the surface concentration of calcium carbonate in paper samples, by applying the linear relationship between the relative infra-red absorption integrals and the concentration. The method was able to detect micro-variations in the surface concentration and could also distinguish between different sheets as well as between the top and bottom side of one sheet. The samples were also split and the calcium carbonate concentration was determined within and compared to bulk calcium carbonate concentration determined from ash testing. The surface results were also compared with analysed scanning electron microscopy images generated from back-scattering electrons. The comparison shows that both sets of results are in excellent agreement. Depending on the sample, large errors (95% confidence) were observed. These, however, are caused by micro-variations of the surface concentration, rather than by inaccuracies of the technique, which is estimated to be less than 1%. Furthermore, measurements of various sample orientations suggest that anisotropic polarisation effects can be neglected. The method can be applied to paper and cellulose matrices having calcium carbonate filler contents of less than 50%. Due to spectral overlaps it is not suitable to determine kaolin filler contents.