7 resultados para Illinois. Ambient Air Monitoring Section

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of a solar-boosted heat pump water heater (HPWH) operating under full load and part load conditions was determined in an outdoor experimental study. The system utilised flat unglazed aluminium solar evaporator panels to absorb solar and ambient energy. Absorbed energy was transferred to the water tank by means of the heat pump and a wrap around condenser coil on the outside of the tank. The system COP was found to be in the range of 5–7 under clear daytime conditions and 3–5 under clear night-time conditions. Using part load testing of the HPWH system it was found that concentrating the coils in the lower portion of the tank could increase the efficiency of the condenser coil. It was also shown that there exists a generalised linear relationship that can be used to describe the system COP in terms of the temperature difference between the water in the storage tank and the ambient air.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A number of transition metal nitrides and oxynitrides, which are actively investigated today as electrode materials in a wide range of energy conversion and storage devices, possess an oxide layer on the surface. Upon exposure to ambient air, properties of this layer progressively change in the process known as "ageing". Since a number of electrochemical processes involve the surface or sub-surface layers of the active electrode compounds only, ageing could have a significant effect on the overall performance of energy conversion and storage devices. In this work, the influence of the ageing of tungsten and molybdenum oxynitrides on their electrochemical properties in supercapacitors is explored for the first time. Samples are synthesised by the temperature-programmed reduction in NH3 and are treated with different gases prior to exposure to air in order to evaluate the role of passivation in the ageing process. After the synthesis, products are subjected to controlled ageing and are characterised by low temperature nitrogen adsorption, X-ray photoelectron spectroscopy and transmission electron microscopy. Capacitive properties of the compounds are evaluated by performing cyclic voltammetry and galvanostatic charge and discharge measurements in the 1 M H2SO4 electrolyte. © 2014 the Partner Organisations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Exhaled air temperature (T exh) has a paramount effect on respiratory water loss during flight. For migratory birds, low T exh potentially reduces water loss and increases flight range. However, only three studies provide empirical data on T exh during flight. The aim of this study was to record T exh of birds during rest and flight at a range of controlled ambient temperatures (T amb). One wigeon and two teal flew a total of 20 times in a wind tunnel at T amb ranging from 1° to 24°C. T exh during flight did not differ between the two species and was strongly correlated with T amb (T exh=1.036 T amb + 13.426; R2=0.58). In addition, body temperature had a weak positive effect on T exh. At a given T amb, T exh was about 5°C higher during flight than at rest.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Within the marine environment, aerial surveys have historically centred on apex predators, such as pinnipeds, cetaceans and sea birds. However, it is becoming increasingly apparent that the utility of this technique may also extend to subsurface species such as pre-spawning fish stocks and aggregations of jellyfish that occur close to the surface. In light of this, we tested the utility of aerial surveys to provide baseline data for 3 poorly understood scyphozoan jellyfish found throughout British and Irish waters: Rhizostoma octopus, Cyanea capillata and Chrysaora hysoscella. Our principal objectives were to develop a simple sampling protocol to identify and quantify surface aggregations, assess their consistency in space and time, and consider the overall applicability of this technique to the study of gelatinous zooplankton. This approach provided a general understanding of range and relative abundance for each target species, with greatest suitability to the study of R. octopus. For this species it was possible to identify and monitor extensive, temporally consistent and previously undocumented aggregations throughout the Irish Sea, an area spanning thousands of square kilometres. This finding has pronounced implications for ecologists and fisheries managers alike and, moreover, draws attention to the broad utility of aerial surveys for the study of gelatinous aggregations beyond the range of conventional ship-based techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A series of digital frequency filters (DFFs) were designed to screen diverse noises and the spectrographic analysis was conducted to isolate complex boundary reflection, which obscures the damage-induced signals. The scale-averaged wavelet power (SAP) technique was applied to enhance
the measurement accuracy of Time of Flight (TOF). As an example, the propagation characteristics of elastic wave in a structural beam of square cross-section were analyzed using such an approach and verified experimentally and numerically, with the consideration of the complicated wave scatter caused by the non-ignorable section dimensions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Whilst air conditioning systems increase thermal comfortableness in vehicles, they also raise the energy consumption of vehicles. Achieving thermal comfort in an energy-efficient way is a difficult task requiring good coordination between engine and the air conditioning system. This paper presents a coordinated energy management system to reduce the energy consumption of the vehicle air conditioning system while maintaining the thermal comfortableness. The system coordinates and manages the operation of evaporator, blower, and fresh air and recirculation gates to provide the desired comfort temperature and indoor air quality, under the various ambient and vehicle conditions, the energy consumption can then be optimized. Three simulations of the developed coordinated energy management system are performed to demonstrate its energy saving capacity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

 Noncontact detection characteristic of Doppler radar provides an unobtrusive means of respiration detection and monitoring. This avoids additional preparations, such as physical sensor attachment or special clothing, which can be useful for certain healthcare applications. Furthermore, robustness of Doppler radar against environmental factors, such as light, ambient temperature, interference from other signals occupying the same bandwidth, fading effects, reduce environmental constraints and strengthens the possibility of employing Doppler radar in long-term respiration detection, and monitoring applications such as sleep studies. This paper presents an evaluation in the of use of microwave Doppler radar for capturing different dynamics of breathing patterns in addition to the respiration rate. Although finding the respiration rate is essential, identifying abnormal breathing patterns in real-time could be used to gain further insights into respiratory disorders and refine diagnostic procedures. Several known breathing disorders were professionally role played and captured in a real-time laboratory environment using a noncontact Doppler radar to evaluate the feasibility of this noncontact form of measurement in capturing breathing patterns under different conditions associated with certain breathing disorders. In addition to that, inhalation and exhalation flow patterns under different breathing scenarios were investigated to further support the feasibility of Doppler radar to accurately estimate the tidal volume. The results obtained for both experiments were compared with the gold standard measurement schemes, such as respiration belt and spirometry readings, yielding significant correlations with the Doppler radar-based information. In summary, Doppler radar is highlighted as an alternative approach not only for determining respiration rates, but also for identifying breathing patterns and tidal volumes as a preferred nonwearable alternative to the conventional - ontact sensing methods.