8 resultados para Geosynthetic

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gas flow unified measurement system (UMS-G) for sequential measurement of gas diffusion and gas permeability of geosynthetic clay liners (GCLs) under applied stress conditions (2 to 20 kPa) is described. Measurements made with the UMS-G are compared with measurements made with conventional experimental devices and are found to give similar results. The UMS-G removes the need to rely on two separate systems and increases further the reliability of the gas properties’ measurements. This study also shows that the gas diffusion and gas permeability reduce greatly with the increase of both gravimetric water content and apparent degree of saturation. The effect of applied stress on gas diffusion and gas permeability is found to be more pronounced at gravimetric water content greater than 60%. These findings suggest that at a nominal overburden stress of 20 kPa, the GCL used in the present investigation needs to be hydrated to 134% gravimetric water content (65% apparent degree of saturation) before gas diffusion and gas permeability drop to 5.5 × 10−11 m2·s−1 and 8.0 × 10−13 m·s−1, respectively, and to an even higher gravimetric water content (apparent degrees of saturation) at lower stress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the performance of bentonite components of geosynthetic clay liners (GCLs) when exposed to aggressive leachates using the fluid loss test and provides a possible quick method for estimating the effect of acidic conditions on hydraulic conductivity. Fluid loss generally increases with increasing acid concentrations. Hydraulic conductivity values back-calculated from the fluid loss tests (kFL) are compared with the values measured using a flexible-wall permeameter (kTri).Generally, the predicted hydraulic conductivity values are conservative (kFL/kTri > 1) under water and low acid concentrations(≤0.015 mol/L). However, the back-calculated hydraulic conductivity is shown to be nonconservative (kFL/kTri < 1) at high acid concentrations (≥0.125 mol/L).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An initially wet contact filter paper test (IW-CFPT) and an initially dry contact filter paper test (ID-CFPT) were used to examine the wetting paths of geosynthetic clay liners, including non-contact filter paper tests for comparative purposes. The CFPTs were applied to both geosynthetic clay liner faces to examine the effect of geotextile type on capillary contact. The non-woven geotextile face was found to be more likely to cause capillary breaks than the woven geotextile face. Both IW- and ID-CFPTs were found to be applicable to geosynthetic clay liners within their accurate upper matric suction measurement limits of 146 kPa and 66 kPa, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results of a series of gas permeability tests, with monitoring of gravimetric/volumetric moisture content and total suction, on a commercially available needle-punched geosynthetic clay liner (GCL) are presented. GCL specimens were partially hydrated with deionised water under 2 and 20 kPa confinement prior to testing. The tests were conducted at differential pressures ranging from 1 to 10 kPa. Gas permeability was found to decrease with an increase in gravimetric/volumetric moisture content and a decrease of suction. The effect of the preconditioning stress was found to be more pronounced at gravimetric moisture contents greater than 40% (25% apparent degree of saturation, 0·30 m3/m3 volumetric moisture content), and suctions less than 1·6 MPa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability of geosynthetic clay liners (GCLs) to contain acidic mining leachates is examined. The results of saturated hydraulic conductivity (k) of two GCLs permeated with sulfuric acid solutions (H2SO4) at 0.015M, 0.125M and 0.5M concentrations are reported. Also, the saturated k values of consolidated (35kPa) bentonite cakes made from sodium bentonite extracted from both GCLs were compared to a commonly used magnesium-sodium form bentonite. Chemical compatibility and effects of pre-hydration and effective stress were assessed as part of this study. Results indicated that an increased acid concentration (ionic strength) increased the k of all tested specimens. The ratio of the k0.5 values for non-prehydrated specimens permeated with 0.5M H2SO4 to the kw values for specimens permeated with deionized (DI) water (k0.5/kw) ranged from 10 to 110. Pre-hydration (50-140% water content) and increased effective stress (35-200kPa) improved the performance of GCLs (lower k). Strong correlations were observed between k and liquid limit and swell index parameters independent of pre-hydration and effective stress in this study. However, care should still be taken when using these correlations to evaluate hydraulic performance because the intrinsic micro-structure properties of bentonite, such as porosity, should also be considered. This work showed that, for example, high SI of bentonite does not translate necessarily to a better hydraulic performance of GCLs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bentonite is a natural clay mineral widely used in the mining and solid waste containment industry, for example, as a soil mixture for the construction of seepage barriers, or as a component of geosynthetic clay liners (GCLs), to provide low hydraulic conductivity. However, degradation of bentonites generally occurs when permeated with acid solutions, such as encountered in mining applications, which may influence physical properties, and particularly, the hydraulic performance of geosynthetic clay liners.In this paper, properties such as Atterberg limits, free swell index, and fluid loss of three bentonites were measured with different concentrations of sulphuric acid solutions. These properties were found to deteriorate even with low (0.015 M) sulphuric acid solutions; higher concentrations (up to 1 M) resulted in larger degradation. X-ray diffraction and infrared spectroscopy were used to monitor the change of bentonites after interaction with the acid solutions. Acid leachates in general result in the overall degradation of the hydraulic performance of geosynthetic clay liners and potentially, any bentonite-soil mixture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of adding glycerol carbonate (GC) or propylene carbonate (PC) to sodium (Na)-bentonite on the hydraulic performance of geosynthetic clay liners (GCLs) under hypersaline conditions is examined. Fluid loss (FL), swell index (SI) and solution retention capacity (SRC) measurements were carried out to compare the potential hydraulic performance of these two cyclic organic carbonates (COCs) as bentonite modifiers. A modified FL test enabled quantitative measurement of both the water retention characteristics of untreated and COC modified bentonites as well as calculation of hydraulic conductivity values. Tests under aggressively saline conditions (ionic strength, I ≥ 1 M of NaCl and ≥3 M of CaCl2) showed that at a mass ratio of 1:1 (GC to bentonite), the FL of a GC-Na-bentonite was ≈40–104 mL in NaCl and ≈61–91 mL in CaCl2. This was about 10–20 mL and 70–200 mL, respectively, lower than that of a comparable PC-Na-bentonite (1:1 PC to bentonite) and untreated Na-bentonite. Greater swelling (SI) and greater solution retention capacity (SRC) was observed for the GC treated Na-bentonite compared to untreated Na-bentonite in all salt solutions, and for PC-Na-bentonite at high ionic strength of both NaCl and CaCl2 solutions, demonstrating the superior hydraulic barrier performance of COC-bentonites under severely saline conditions. Experiments conducted in flexible-wall permeameters with I = 3 M CaCl2 showed approximately one order of magnitude lower (∼10−11 m/s vs ∼1.9 × 10−10 m/s) hydraulic conductivity of GC treated bentonite cake compared to the k value of the untreated Na-bentonite cake. Calculated hydraulic conductivity from fluid loss tests estimated the measured values in a conservative way (overestimation).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An overview of the design and performance of geosynthetics in composite barrier systems for biopiles used to remediate hydrocarbon-contaminated soil at Casey Station, Antarctica, is presented. Seven instrumented biopiles were constructed over three field seasons. To minimize the risk of hydrocarbon migration to groundwater, composite barrier systems were used (each using different combinations of geosynthetic clay liners (GCLs), high density polyethylene (HDPE) geomembranes (GMB), and geotextiles (GTXs)). One biopile used a co-extruded geomembrane (HDPE with an ethylene vinyl alcohol (EVOH) core). The liner system was subject to a combination of coupled phenomena that could interact and affect the GMB-GCL composite barrier performance. The exposure conditions involved potential freeze-thaw cycling, hydration-desiccation cycles, cation exchange, direct and diffusive exposure to hydrocarbons. The effect of these phenomena was investigated by monitoring GCL and GMB sacrificial coupons. GCL coupons were placed between the main GCL component and the main geomembrane component of the composite liner and GMB coupons placed between the main GMB sheet and the GTX protection layer. Coupons were exhumed from the biopiles each year. The exhumed GCL field moisture content values ranged from 162% to 22%. After three (3) years in the field, GCL coupons that had undergone at least one hydration/desiccation cycle showed no significant change in swell index values or fluid loss values. The measured hydraulic conductivity of exhumed GCL coupons from Biopiles 1 and 2 (3 × 10-11 m s-1) was within the expected range and not significantly different from the values for virgin GCL. GMB coupons exhumed after three years from Biopiles 1 and 2 showed no significant change in oxidative induction time (OIT), melt flow index or tensile properties. Diffusion tests were performed as an index test for establishing the performance of the GMBs as a diffusive barrier to hydrocarbons, with permeation parameters for BTEX contaminants ranging from P g = 0.9-9.2 × 10-13 m2 s-1 for the exhumed GMB (with values depending on the contaminant and GMB). These values were similar to the parameters obtained for virgin GMBs and there was no significant change with field exposure, with GMBs appearing to be performing well.