17 resultados para GOLD ELECTRODE

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

All rights reserved. A graphene nanodots-encaged porous gold electrode via ion beam sputtering deposition (IBSD) for electrochemical sensing is presented. The electrodes were fabricated using Au target, and a composite target of Al and graphene, which were simultaneously sputtered onto glass substrates by Ar ion beam, followed with hydrochloric acid corrosion. The as-prepared graphene nanodots-encaged porous gold electrodes were then used for the analysis of heavy metal ions, e.g. Cu2+ and Pb2+ by Osteryoung square wave voltammetry (OSWV). These porous electrodes exhibited enhanced detection range for the heavy metal ions due to the entrapped graphene nanodots in 3-D porous structure. In addition, it was also found that when the thickness of porous electrode reached 40 nm the detection sensitivity came into saturation. The linear detection range is 0.009-4 μM for Cu2+ and 0.006-2.5 μM for Pb2+. Good reusability and repeatability were also observed. The formation mechanism and 3-D structure of the porous electrode were also investigated using scanning electron microscope (SEM), transmission electron microscope (TEM) and X-ray photoelectron spectra (XPS). This graphene entrapped 3-D porous structure may envision promising applications in sensing devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A uniform graphene nanodots inlaid porous gold electrode was prepared via ion beam sputtering deposition (IBSD) and mild corrosion chemistry. HRTEM, SEM, AFM and XPS analyses revealed the successful fabrication of graphene nanodots inlaid porous gold electrode. The as-prepared porous electrode was used as π-orbital-rich drug loading platform to fabricate an electrochemically controlled drug release system with high performance. π-orbital-rich drugs with amino mioety, like doxorubicin (DOX) and tetracycline (TC), were loaded into the graphene nanodots inlaid porous gold electrode via non-covalent π-π stacking interaction. The amino groups in DOX and TC can be easily protonated at acidic medium to become positively-charged NH3(+), which allow these drug molecules to be desorbed from the porous electrode surface via electrostatic repulsion when positive potential is applied at the electrode. The drug loading and release experiment indicated that this graphene nanodots inlaid porous gold electrode can be used to conveniently and efficiently control the drug release electrochemically. Not only did our work provide a benign method to electrochemically controlled drug release via electrostatic repulsion process, it also enlighten the promising practical applications of micro electrode as a drug carrier for precisely and efficiently controlled drug release via embedding in the body.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Electrochemical sensors for copper ions in environmental samples were prepared by modifying gold electrodes with l-cysteine by self-assembly. The adsorption of l-cysteine on gold electrodes was studied by electrochemical reductive desorption in 0.5 M KOH, and the interaction of l-cysteine with copper ions was investigated by cyclic voltammetry, chronoamperometry and X-ray photoelectron spectroscopy. At low concentrations the ratio of l-cysteine to bound Cu(II) is 2:1. At higher concentrations (0.1 M) copper reacts with adsorbed cysteine forming copper sulfide on the electrode surface. On a modified l-cysteine gold electrode, Osteryoung square wave voltammetric determination of Cu(II) with a detection limit below 5 ppb has been demonstrated.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

An electrochemical sensor for the detection of Cu2+ is reported which incorporates poly-l-aspartic acid (PLAsp) with 32–96 aspartate units as a selective ligand for the metal ion. PLAsp is covalently attached to a gold electrode modified with a monolayer of 3-mercaptopropionic acid using carbodiimide coupling via an N-hydroxysuccinimide (NHS) ester intermediate. The acid side groups and deprotonated peptide nitrogens on two aspartate moieties are thought to be primarily responsible for chelation of Cu2+, which remains bound when reduced to Cu+. A consequence of the multiple binding points that are available with a polypeptide is the low detection limit. The lowest concentration detected was 3 nM (0.2 ppb) achieved with Osteryoung square wave voltammetry. This detection limit compares favourably with that of ICP-OES and previously reported cysteine-modified electrodes. Analysis of tap and lake water samples using the PLAsp-modified electrode agreed well with ICP-OES analysis of the same samples.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Herein, a uniform three-dimensional (3-D) graphene nanodots-encaged porous gold electrode was prepared via ion beam sputtering deposition (IBSD) and mild corrosion chemistry for efficient enzyme electrode fabrication. Enzymes, like glucose oxidase and catalase, were modified with pyrene functionalities and then loaded into the graphene nanodots encaged porous gold electrode via non-covalent π-π stacking interaction between pyrene and graphene. The fabricated enzyme electrodes showed profound reusability and repeatability, high sensitivity, inherent selectivity and enhanced detection range. As for glucose analysis a broad linear range from 0.05 to 100 mM was obtained and the linear range for hydrogen peroxide was 0.005 to 4 mM. Detection limits of 30 μM for glucose and 1 μM for hydrogen peroxide were achieved (S/N = 3), respectively. These electrodes can be applied to analyze the clinical samples with reliable results. The formation mechanism and 3-D structure of the porous electrode were investigated using high resolution transmission electron microscope (HRTEM), atomic force microscopy (AFM), scanning electron microscope (SEM) and electrochemical impedance spectroscopy (EIS). Most importantly, various other ideal biosensors can be fabricated using the same porous electrode and the same enzyme modification methodology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An electrochemical metal ion sensor has been developed with a detection limit of less than 0.2 ppt by the covalent attachment of the tripeptide Gly-Gly-His as a recognition element to a 3-mercaptopropionic acid modified gold electrode.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The modification of electrodes with the tripeptide Gly–Gly–His for the detection of copper in water samples is described in detail. The tripeptide modified electrode was prepared by first self-assembling 3-mercaptopropionic acid (MPA) onto the gold electrode followed by covalent attachment of the tripeptide to the self-assembled monolayer using carbodiimide coupling. The electrodes were characterized using electrochemistry, a newly developed mass-spectrometry method and quantum mechanical calculations. The mass spectrometry confirmed the modification to proceed as expected with peptide bonds formed between the carboxylic acids of the MPA and the terminal amine of the peptide. Electrochemical measurements indicated that approximately half the MPA molecules in a SAM are modified with the peptide. The peptide modified electrodes exhibited high sensitivity to copper which is attributed to the stable 4N coordinate complex the peptide formed around the metal ion to give copper the preferred tetragonal coordination. The formation of a 4 coordinate complex was predicted using quantum mechanical calculation and confirmed using mass spectrometry. The adsorption of the copper to the peptide modified electrode was consistent with a Langmuir isotherm with a binding constant of (8.1 ± 0.4) 1010 M−1 at 25 °C.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The fabrication of enzyme electrodes using self-assembled monolayers (SAMs) has attracted considerable interest because of the spatial control over the enzyme immobilization. A model system of glucose oxidase covalently bound to a gold electrode modified with a SAM of 3-mercaptopropionic acid was investigated with regard to the effect of fabrication variables such as the surface topography of the underlying gold electrode, the conditions during covalent attachment of the enzyme and the buffer used. The resultant monolayer enzyme electrodes have excellent sensitivity and dynamic range which can easily be adjusted by controlling the amount of enzyme immobilized. The major drawback of such electrodes is the response which is limited by the kinetics of the enzyme rather than mass transport of substrates. Approaches to bringing such enzyme electrodes into the mass transport limiting regime by exploiting direct electron transfer between the enzyme and the electrode are outlined.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A highly selective and sensitive electrochemical biosensor has been developed that detects DNA hybridization by employing the electrocatalytic activity of ferrocene (Fc) bearing cyclen complexes (cyclen = 1,4,7,10-tetraazacyclododecane, Fc[Zn(cyclen)H2O]2(ClO4)4 (R1), Fc(cyclen)2 (R2), Fc[Zn(cyclen)H2O](ClO4)2 (R3), and Fc(cyclen) (R4)). A sandwich-type approach, which involves hybridization of a target probe hybridized with the preimmobilized thiolated capture probe attached to a gold electrode, is employed to fabricate a DNA duplex layer. Electrochemical signals are generated by voltammetric interrogation of a Fc bearing Zn−cyclen complexes that selectively and quantitatively binds to the duplex layers through strong chelation between the cyclen complexes and particular nucleobases within the DNA sequence. Chelate formation between R1 or R3 and thymine bases leads to the perturbation of base-pair (A−T) stacking in the duplex structure, which greatly diminishes the yield of DNA-mediated charge transport and displays a marked selectivity to the presence of the target DNA sequence. Coupling the redox chemistry of the surface-bound Fc bearing Zn−cyclen complex and dimethylamine provides an electrocatalytic pathway that increases sensitivity of the assay and allows the 100 fM target DNA sequence to be detected. Excellent selectivity against even single-base sequence mismatches is achieved, and the DNA sensor is stable and reusable.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A strategy for a fast (ca. 20 min), specific, electrochemical immunoassay for the cardiac biomarker creatine kinase (CK) and the human cytokine interleukin 10 (IL10) has been developed in this paper. The polyaniline modified gold surface formed from electrochemical reduction of diazonium salt supplies a solid substrate to link the activated carboxylic acid groups from the antibodies, which were labelled with ferrocene. The direct electrochemistry of ferrocene allows the analysis of protein markers with good sensitivity. The creatine kinase sensor demonstrates limit of detection of 0.5 pg mL−1 in a physiological Krebs-Henseleit solution. The anti-IL10 antibody retained fluorescence activity after further coupling to ferrocene and covalent immobilization on to a gold electrode, showing a linear detection range for IL-10 from 0.001 ng mL−1 to 50 ng mL−1 in PBS. We attribute the high sensitivity to the well-controlled modified surface which results in end–on antibodies that can specifically capture the antigen with ease.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel strategy for selective and sensitive electrochemical lead ion (Pb2+) biosensor was developed based on the single-stranded DNAzyme catalytic beacon. A DNAzyme that requires Pb2+ for activation was selected and labeled with redox-active ferrocene (Fc) for signal transducer. The Fc-labeled single-stranded DNAzyme (Fc-ssDNAzyme) was self-assembled through SAu bonding on a gold electrode surface. In the presence of Pb2+, the ssDNAzyme was activated and catalyzed the hydrolytic cleavage of the substrate strand, resulting in the removal of the substrate strand along with the Fc from the Au electrode surface. The dissociation of Fc caused a decrease of electrochemical signal ("signal-off"). Under the optimal conditions, the electrochemical signal of Fc decreased directly with the increasing Pb2+ concentration, exhibiting a linear response in the range of 0.5nM to 5μM with a detection limit of 0.25nM. This strategy is simple, sensitive and selective with the minimal reagents and working steps, thereby holds great potential for Pb2+ detection in real environmental sample analysis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, the influence of chemically reduced graphene oxide sheets (CRGOs) on the electrochemical performance through methyl or carboxylic acid terminated self-assembled monolayers (SAMs) is reported. The gold electrode was initially modified with methyl or carboxylic acid terminated alkanethiols with various carbon chain lengths (n = 4, 6, 8 and 11) and subsequently immobilization of the CRGOs on a SAM surface was achieved via a hydrophobic and electrostatic interaction. By using the potassium ferricyanide as a redox probe, it was observed that CRGOs could effectively enhance the heterogeneous electron transfer (ET) of the SAM due to a tunneling effect. The assemblies based on thiol end groups with methyl head groups were observed to afford more hydrophobic interaction binding with CRGOs with a higher reduction time than the assemblies developed with thiol end groups and a -COOH group which were shown to bind more electrostatically with CRGOs, a lowering reduction time. The Nyquist plots developed show a gradual decrease of the charge transfer resistance (Rct) of [Fe(CN)6]3-/4- redox couple at the CRGOs-SAMs electrode with the controllable adsorption of different CRGO's onto the SAM. Depending on the chain length and terminal functional group the electron transfer rate kinetics were observed to differ considerably.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Voltammetric behavior at gold electrodes in aqueous media is known to be strongly dependent on electrode polishing and history. In this study, an electrode array consisting of 100 nominally identical and individually addressable gold disks electrodes, each with a radius of 127 µm, has been fabricated. The ability to analyze both individual electrode and total array performance enables microscopic aspects of the overall voltammetric response arising from variable levels of inhomogeneity in each electrode to be identified. The array configuration was initially employed with the reversible and hence relatively surface insensitive [Ru(NH3)6]3+/2+ reaction and then with the more highly surface sensitive quasi-reversible [Fe(CN)6]3−/4− process. In both these cases, the reactants and products are solution soluble and, at a scan rate of 50 mV s−1, each electrode in the array is assumed to behave independently, since no evidence of overlapping of the diffusion layers was detected. As would be expected, the variability of the individual electrodesʼ responses was significantly larger than found for the summed electrode behavior. In the case of cytochrome c voltammetry at a 4,4′-dipyridyl disulfide modified electrode, a far greater dependence on electrode history and electrode heterogeneity was detected. In this case, voltammograms derived from individual electrodes in the gold array electrode exhibit shape variations ranging from peak to sigmoidal. However, again the total response was always found to be well-defined. This voltammetry is consistent with a microscopic model of heterogeneity where some parts of each chemically modified electrode surface are electroactive while other parts are less active. The findings are consistent with the common existence of electrode heterogeneity in cyclic voltammetric responses at gold electrodes, that are normally difficult to detect, but fundamentally important, as electrode nonuniformity can give rise to subtle forms of kinetic and other forms of dispersion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, six types of typical bio-wastes are used to prepare activated carbons (ACs) by high-temperature carbonization and activation with KOH. A novel electrochemical sensor for rutin was developed based on a peanut shell-derived activated carbon and gold nanoparticle composite modified glassy carbon electrode (P-AC/AuNPs/GCE). The as-synthesized ACs and composites were characterized by a variety of physicochemical techniques. The proposed sensor exhibits ideal electrochemical behavior for rutin with a wide linear range, low detection limit, and good selectivity. The desirable electrochemical performance enables the biomass-derived ACs and their composites to act as new sources of carbonaceous materials for electrochemical sensors.