7 resultados para Flow chemistry

em Deakin Research Online - Australia


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chemiluminescence, the production of light from a chemical reaction, has found widespread use in analytical chemistry. Both tris (2, 2’-bipyridyl) ruthenium (II) and acidic potassium permanganate are chemiluminescence reagents that have been employed for the determination of a diverse range of analytes. This thesis encompasses some fundamental investigations into the chemistry and spectroscopy of these chemiluminescence reactions as well as extending the scope of their analytical applications. Specifically, a simple and robust capillary electrophoresis chemiluminescence detection system for the determination of codeine, O6-methylcodeine and thebaine is described, based upon the reaction of these analytes with chemically generated tris(2,2'-bipyridyl)ruthenium(III) prepared in sulfuric acid (0.05 M). The reagent solution was contained in a glass detection cell, which also held both the capillary and the cathode. The resultant chemiluminescence was monitored directly using a photomultiplier tube mounted flush against the base of the detection cell. The methodology, which incorporated a field amplification sample introduction procedure, realised detection limits (3a baseline noise) of 5 x 10~8 M for both codeine and O6-methylcodeine and 1 x 10~7 M for thebaine. The relative standard deviations of the migration times and the peak areas for the three analytes ranged from 2.2 % up to 2.5 % and 1.9 % up to 4.6 % respectively. Following minor instrumental modifications, morphine, oripavine and pseudomorphine were determined based upon their reaction with acidic potassium permanganate in the presence of sodium polyphosphate. To ensure no migration of the permanganate anion occurred, the anode was placed at the detector end whilst the electroosmotic flow was reversed by the addition of hexadimethrine bromide (0.001% m/v) to the electrolyte. The three analytes were separated counter to the electroosmotic flow via their interaction with a-cyclodextrin. The methodology realised detection limits (3 x S/N) of 2.5 x 10~7 M for both morphine and oripavine and 5 x 10~7 M for pseudomorphine. The relative standard deviations of the migration times and the peak heights for the three analytes ranged from 0.6 % up to 0.8 % and 1.5% up to 2.1 % respectively. Further improvements were made by incorporating a co-axial sheath flow detection cell. The methodology was validated by comparing the results realised using this technique with those obtained by high performance liquid chromatography (HPLC), for the determination of both morphine and oripavine in seven industrial process liquors. A complimentary capillary electrophoresis procedure with UV-absorption detection was also developed and applied to the determination of morphine, codeine, oripavine and thebaine in nine process liquors. The results were compared with those achieved using a standard HPLC method. Although over eighty papers have appeared in the literature on the analytical applications of acidic potassium permanganate chemiluminescence, little effort has been directed towards identifying the origin of the luminescence. It was found that chemiluminescence was generated during the manganese(III), manganese(IV) and manganese(VII) oxidations of sodium borohydride, sodium dithionite, sodium sulfite and hydrazine sulfate in acidic aqueous solution. From the corrected chemiluminescence spectra, the wavelengths of maximum emission were 689 ± 5 nm and 734 ± 5 nm when the reactions were performed in sodium hexametaphosphate and sodium dihydrogenorthophosphate or orthophosphoric acid environments respectively. The corrected phosphorescence spectrum of manganese(II) sulfate in a solution of sodium hexametaphosphate at 77 K, exhibited two peaks with maxima at 688 nm and 730 nm. The chemical and spectroscopic evidence presented strongly supported the postulation that the emission was an example of solution phase chemically induced phosphorescence of manganese(II). Thereby confirming earlier predictions that the chemiluminescence from acidic potassium permanganate reactions originated from an excited manganese(II) species. Additionally, these findings have had direct analytical application in that manganese(IV) was evaluated as a new reagent for chemiluminescence detection. The oxidations of twenty five organic and inorganic species, with solublised manganese(IV), were found to elicit analytically useful chemiluminescence with detection limits (3 x S/N) for Mn(II), Fe(II), morphine and codeine of 5 x 10-8 M, 2.5 x 10-7 M, 7.5 x 10-8 M and 5 x 10-8M, respectively. The corrected emission spectra from four different analytes gave wavelengths of maximum emission in the range from 733 nm up to 740 nm indicating that these chemiluminescence reactions also shared a common emitting species, excited manganese(II). Whilst several analytical problems were addressed in this thesis and answers to certain questions regarding the fundamentals of acidic potassium permanganate chemiluminescence were proposed, there are several areas that would benefit from further research. These are outlined in the final chapter of this thesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This collection of seventy-five publications represents the authors contribution to spectroscopy, separation science and flow analysis. Of particular note are the fundamental investigations into chemiluminescence and the innovative strategies for its utilisation as a sensitive and selective means of detection for several important and challenging problems in analytical chemistry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The research was a detailed investigation into a challenging analytical chemistry problem for the alumina industry. The successful outcomes were derived through innovative reagent chemistry and novel instrumental development. The resultant methodology and instrumentation deployed on this most demanding sample matrix is more robust, reliable and less expensive than anything currently used in this industry worldwide.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Novel flow-cells with integrated confluence points and reaction channels designed for efficient mixing of fast chemiluminescence systems were constructed by machining opposing sides of a polymer chip and sealing the channels with transparent epoxy-acetate films. A hole drilled through the chip provided the conduit from the confluence point on one side to the centre of the reaction zone on the other side, allowing rapid presentation of the reacting mixture to the photodetector. The effectiveness of each flow-cell was evaluated by comparing the chemiluminescence intensity using flow injection analysis methodology, and examining the distribution of light emanating from the reaction zone (captured by photography in a dark room) when the reactants were continuously merged. Although previously reported chemiluminescence detectors constructed by machining channels into polymers have almost exclusively been prepared using transparent materials, we obtained far greater emission intensities using an opaque white chip with a thin transparent seal, which minimised the loss of light through surfaces not exposed to the photomultiplier tube. Furthermore, this approach enabled the exploration of reactor designs that could not be incorporated in traditional coiled-tubing flow-cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Herein we explore modern fabrication techniques for the development of chemiluminescence detection flow-cells with features not attainable using the traditional coiled tubing approach. This includes the first 3D-printed chemiluminescence flow-cells, and a milled flow-cell designed to split the analyte stream into two separate detection zones within the same polymer chip. The flow-cells are compared to conventional detection systems using flow injection analysis (FIA) and high performance liquid chromatography (HPLC), with the fast chemiluminescence reactions of an acidic potassium permanganate reagent with morphine and a series of adrenergic phenolic amines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The performance of curtain flow chromatography column technology with MS detection was evaluated for the analysis of labile compounds. The curtain flow column design allows for separations that are faster and/or more sensitive than conventional columns, depending on how exactly the curtain flow column is configured. For example, when mass spectral detection is employed, the curtain flow column can yield separations that are 5-times faster than conventional columns when the curtain flow and the conventional columns have the same internal diameter. Or when the internal diameter of the conventional column is reduced in order to yield the same analytical through-put as the curtain flow column, the sensitivity on the curtain flow column can be as much as 66-fold higher than the conventional column. As a consequence of the higher analytical through-put less standardization is required in the analysis of labile compounds because less sample degradation is apparent. Consequently the sample integrity is preserved yielding data of a higher quality.