9 resultados para Fission track method

em Deakin Research Online - Australia


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Currently, employers tend to fast rack works where construction can begin while design is still incomplete following three main phases of procurement. This session details a case study of a fast track overseas super high rise building, where an Australian firm acted as a technical expert to provide a detailed report on the failure of the shoring system, while construction of five basements had just started next to a marina. The lessons learnt from the case study are summarized with recommendations to have better practice of the fast track method in complex high rise buildings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dietary lipids and fatty acids are not only fundamental in determining animal performance, but also determine the eating qualities of animal products. Several methods have been used to quantify fatty acid metabolism but most involve expensive in vitro approaches that are not suitable for most laboratories. Furthermore, there is considerable variation between methods with regard to enzyme activity, which makes comparison of results between studies difficult. The recently developed whole-body fatty acid balance method (WBFABM) is a simple and reliable in vivo method for assessing fatty acid metabolism, including rates of liponeogenesis and de novo fatty acid production, β-oxidation of fatty acids and bioconversion (elongation and desaturation) of fatty acids to long-chain polyunsaturated fatty acids. Initially developed for implementation with a fish model, the WBFABM has proven to be a simple and effective method that can be used in any laboratory equipped with a gas chromatography unit. Since its development, it has been used in several farmed finfish feeding trials and in broiler chicken feeding trials. The WBFABM is currently used at research institutions worldwide and its use is increasing in popularity among animal scientists. With this method, it is possible to track the fate of individual dietary fatty acids within the body. The WBFABM could contribute significantly to information generated by animal feeding trials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we describe a supervised learning algorithm that uses selective memory to track concept drift. Unlike previous methods to track concept drift that use window heuristics to adapt to changes, we present an improved approach that discriminates between the instances observed. The advantage of this method is that it allows the system to both adapt to and track drift more accurately as well as filter the noise in the data more effectively. We present the algorithm and compare its performance with FLORA a well known concept drift tracking algorithm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a method of improving level of service in congested urban railways by means of a triple-track line operation for a highly dense urban area with special travel demand characteristics. Where the future travel demand forecasts show sluggish growth or no growth at all, there is little to no incentives for heavy railway investments like quadruple-track extension and construction of new railway routes to alleviate current railway congestion problems. In such a situation, triple-track line operation can be the best alternative due to its moderate investment cost and ease in land acquisition for just an additional single track along the existing tracks. Our simulation investigation in one of the congested railway lines in Tokyo showed that triple track line operation increases railway capacity by 26% and shortens travel time by 38% in peak direction during morning peak hours. These results are encouraging and are useful for removing current railways problems in Tokyo and in similar urban situations elsewhere.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

  Remote human activity monitoring is critical and essential in physiotherapy with respect to the skyrocketing healthcare expenditure and the fast aging population. One of frequently used method to monitor human activity is wearing inertial sensors since it is low-cost and accurate. However, the measurements of those sensors are able only to estimate the orientation and rotation angles with respect to actual movement angles, because of differences in the body’s co-ordination system and the sensor’s co-ordination system. There were numerous studies being conducted to improve the accuracy of estimation, though there is potential for further discussions on improving accuracy by replacing heavy algorithms to less complexity. This research is an attempt to propose an adaptive complementary filter for identifying human upper arm movements. Further, this article discusses a feasibility of upper arm rehabilitation using the proposed adaptive complementary filter and inertial measurement sensors. The proposed algorithm is tested with four healthy subjects wearing an inertial sensor against gold standard, which is the VICON system. It demonstrated root mean squared error of 8.77◦ for upper body limb orientation estimation when compared to gold standard VICON optical motion capture system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In photovoltaic (PV) power generation, partial shading is an unavoidable complication that significantly reduces the efficiency of the overall system. Under this condition, the PV system produces a multiple-peak function in its output power characteristic. Thus, a reliable technique is required to track the global maximum power point (GMPP) within an appropriate time. This study aims to employ a hybrid evolutionary algorithm called the DEPSO technique, a combination of the differential evolutionary (DE) algorithm and particle swarm optimization (PSO), to detect the maximum power point under partial shading conditions. The paper starts with a brief description about the behavior of PV systems under partial shading conditions. Then, the DEPSO technique along with its implementation in maximum power point tracking (MPPT) is explained in detail. Finally, Simulation and experimental results are presented to verify the performance of the proposed technique under different partial shading conditions. Results prove the advantages of the proposed method, such as its reliability, system-independence, and accuracy in tracking the GMPP under partial shading conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: For many patients clinical prescription of walking will be beneficial to health and accelerometers can be used to monitor their walking intensity, frequency and duration over many days. Walking intensity should include establishment of individual specific accelerometer count, walking speed and energy expenditure (VO2) relationships and this can be achieved using a walking protocol on a treadmill or overground. However, differences in gait mechanics during treadmill compared to overground walking may result in inaccurate estimations of free-living walking speed and VO2. The aims of this study were to compare the validity of track- and treadmill-based calibration methods for estimating free-living level walking speed and VO2 and to explain between-method differences in accuracy of estimation.

METHODS: Fifty healthy adults [32 women and 18 men; mean (SD): 40 (13) years] walked at four pre-determined speeds on an outdoor track and a treadmill, and completed three 1-km self-paced level walks while wearing an Actigraph monitor and a mobile oxygen analyser. Speed- and VO2-to-Actigraph count individual calibration equations were computed for each calibration method. Between-method differences in calibration equation parameters, prediction errors, and relationships of walking speed with VO2 and Actigraph counts were assessed. RESULTS: The treadmill-calibration equation overestimated free-living walking speed (on average, by 0.7 km · h(-1)) and VO2 (by 4.99 ml · kg(-1) · min(-1)), while the track-calibration equation did not. This was because treadmill walking, from which the calibration equation was derived, produced lower Actigraph counts and higher VO2 for a given walking speed compared to walking on a track. The prediction error associated with the use of the treadmill-calibration method increased with free-living walking speed. This issue was not observed when using the track-calibration method. CONCLUSIONS: The proposed track-based individual accelerometer calibration method can provide accurate and unbiased estimates of free-living walking speed and VO2 from walking. The treadmill-based calibration produces calibration equations that tend to substantially overestimate both VO2 and speed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Qualitative assessment of the progress in physical rehabilitation largely depends on accurate measurement of the range of movements and other kinematic parameters. In clinical practice, wearable inertial sensors have proved to be a potential candidate for such measurements, over the traditional marker based optical systems due to cost and space considerations. The accuracy of wearable sensors have a significant dependence on the initial orientation calibration and the assumption that the sensor will not slip or move with respect to the attached limb. This article introduces a novel calibration algorithm to correct initial orientation misalignment, as well as to track and correct subsequent alignment errors progressively throughout the experiment. The theoretical assertions are validated through controlled experiments with simulated accelerometer and gyroscope measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Long-term, off-site human monitoring systems are emerging with respect to the skyrocketing expenditures engaged with rehabilitation therapies for neurological diseases. Inertial/magnetic sensor modules are well known as a worthy solution for this problem. Much attention and effort are being paid for minimizing drift problem of angular rates, yet the rest of kinematic measurements (earth’s magnetic field and gravitational orientation) are only themselves capable enough to track movements applying the theory for solving historicalWahbas Problem. Further, these solutions give a closed form solution which makes it mostly suitable for real time Mo-Cap systems. This paper examines the feasibility of some typical solutions of Wahba’s Problem named TRIAD method, Davenport’s q method, Singular Value Decomposition method and QUEST algorithm upon current inertial/magnetic sensor measurements for tracking human arm movements. Further, the theoretical assertions are compared through controlled experiments with both simulated and actual accelerometer and magnetometer measurements.