12 resultados para Equivalent circuits

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Losing information causes losing power. Information is lost when the input vector cannot be uniquely recovered from the output vector of a combinational circuit. The input vector of reversible circuit can be uniquely recovered from the output vector. In this study we have emphasized on the design of reversible adder circuits that is efficient in terms of gate count, garbage outputs and quantum cost and that can be technologically mapped. It has been analyzed and demonstrated that the results of our proposed adder circuits shows better performance compared to similar type of existing designs. Technology independent equations required to evaluate these circuits have also been given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This document reports on the results and findings of a national survey of Directors (or equivalent) of Teaching and Learning Centres at Australian universities. The respondent group included 31 out of the 38 Centres invited to participate, and was a highly representative sample of the generally recognised institutional groupings in Australian higher education. While there is wide variation in the characteristics of individual Centres, the richness of which can only be appreciated by exploring the results and findings in detail, a summary of the results is provided here in the form of a description of a mythical ‘average’ Australian university Teaching and Learning Centre.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the presence of single-use airway filters, we quantified anaesthetic circuit aerobic microbial contamination rates when changed every 24 h, 48 h and 7 days. Microbiological samples were taken from the interior of 305 anaesthetic breathing circuits over a 15-month period (3197 operations). There was no significant difference in the proportion of contaminated circuits when changed every 24 h (57/105 (54%, 95% CI 45–64%)) compared with 48 h (43/100 (43%, 95% CI 33–53%, p = 0.12)) and up to 7 days (46/100 (46%, 95% CI 36–56%, p = 0.26)). Median bacterial counts were not increased at 48 h or 7 days provided circuits were routinely emptied of condensate. Annual savings for one hospital (six operating theatres) were $AU 5219 (£3079, €3654, $US 4846) and a 57% decrease in anaesthesia circuit steriliser loads associated with a yearly saving of 2760 kWh of electricity and 48 000 l of water. Our findings suggest that extended circuit use from 24 h up to 7 days does not significantly increase bacterial contamination, and is associated with labour, energy, water and financial savings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

 Development of an optimum rectenna for radio frequency energy harvesting in miniature head-mountable deep brain stimulation (DBS) devices. The designed miniature rectenna can operate a DBS device without battery for murine preclinical research. The battery-less operation of the device eliminates battery related difficulties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ionic polymers have attracted considerable attention due to their interesting sensing and actuating behavior which make them a proper choice for use in a wide range of applications including biomimetic robots and biomedical devices. The complicated electro-chemo-mechanical dynamics of ionic polymer actuators is a drawback for their applications in functional devices. Therefore, establishing a mathematical model which could effectively predict the actuators' dynamic behavior is of great interest. In this paper, a mathematical model, named equivalent dynamic thermoviscoelastic (EDT) model, based on thermal analogy and beam theory is proposed for dynamic analysis of bending-type ionic polymer actuators. Then, the developed model is extended for analyzing the performance of the actuator in finite element software. The finite element analysis of the actuator enables consideration of material and geometric nonlinearities and facilitates modeling of functional devices based on the ionic polymer actuators. The proposed modeling approach is validated using experimental data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article proposes a model to predict uniaxial and multiaxial ratcheting life by addressing the three primary parameters that influence failure life: fatigue damage, ratcheting damage and the multiaxial loading path. These three factors are addressed in the present model by (a) the stress amplitude for fatigue damage, (b) mean stress-dependent Goodman equation for ratcheting damage and (c) an inherent weight factor based on average equivalent stress to account for the multiaxial loading. The proposed model requires only two material constants which can be easily determined from uniaxial symmetric stress-controlled fatigue tests. Experimental ratcheting life data collected from the literature for 1025 and 42CrMo steel under multiaxial proportional and nonproportional constant amplitude loading ratcheting with triangular sinusoidal and trapezoidal waveform (i.e. linear, rhombic, circular, elliptical and square stress paths) have shown good agreement with the proposed model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses design and fabrication processes in the development of a wearable and flexible conductive resistive sensor. The design and development of the sensor involve the use of Sn-Ag-Cu (SAC)plated Nylon fabric, precisionfused deposition modeling(FDM) using silicone and petrolatum for etch-resistant masks using the EnvisionTEC GmbH Bioplotter, and wet etching using Chromium, Ammonium Persulphate, and Salt-Vinegar etching solutions. Preliminary testing with other mask types, development processes, and sensor design approaches for various applications are discussed.