22 resultados para Electric field analysis

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Concentrated electric field is crucial in generation of needleless electrospinning; the electric field profile together with electric field intensity of the spinneret directly affect the needleless electrospinning performance. Understanding the electric field of different spinnerets would definitely benefit the design and optimization of needleless electrospinning. Three-dimensional (3D) finite element analysis has been used to analyze the electric field profile and electric field intensity of different spinnerets for needleless electrospinning by using the simulation software COMSOL Multiphysics 3.5a. It has been found that evolution of the spinneret of needleless electrospinning from cylinder to multiple disks and then to multiple rings results in stronger and more concentrated electric field. The analysis based on 3D simulation of the electric field could benefit further development of needleless electrospinning in which the production rate and quality of as-spun nanofibers are of great importance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose is to explore the inherent complexity of Kurt Lewin's force field theory through applied analysis of organizational case examples and related methods. The methodology applies a range of tools from the consultancy research domain, including force field analysis of complex organizational scenarios, and applies bricolage and corroboration to emerging discoveries from semi-structured interviews, author experience, critical reflection and literature survey. Findings are that linear representation of internal and external forces in organizational applications of field theory does not fully explain the paradox of inverse vectors in the forces of change. The force field is not an impermeable thing; instead, it morphs. Examples of the inverse principle and its effects are detailed and extended in this analysis. The implications of the research are that force field analysis and related change processes promoted in organizational change literature run the risk of missing key complexities. The inclusion of the inverse principle can provide enhanced, holistic understanding of the prevailing forces for change. The augmentation of the early work of Kurt Lewin, and extension of previous analyses of his legacy in the Journal of Change Management and elsewhere, provide, in this article, change analysis insights that align well with current organizational environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The behavior of Liquid N,N-dimethylformamide subjected to a wide range of externally applied electric fields (from 0.001 V/nm to 1 V/nm) has been investigated through molecular dynamics simulation. To approach the objective the AMOEBA polarizable force field was extended to include the interaction of the external electric field with atomic partial charges and the contribution to the atomic polarization. The simulation results were evaluated with quantum mechanical calculations. The results from the present force field for the liquid at normal conditions were compared with the experimental and molecular dynamics results with non-polarizable and other polarizable force fields. The uniform external electric fields of higher than 0.01 V/nm have a significant effect on the structure of the liquid, which exhibits a variation in numerous properties, including molecular polarization, local cluster structure, rotation, alignment, energetics, and bulk thermodynamic and structural properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, a spinning metal wire collector was employed to continuously collect polyacrylonitrile (PAN) nanofibers produced by a disc fiber generator and coil them around a polyethylene terephthalate (PET) yarn. The obtained composite yarns exhibited a core/shell structure (PET yarn/PAN nanofibers) with nanofibers orderly arranged on the surface of the PET yarn. The electric field analysis showed that the position of metal wire had insignificant effect on the formed electric field and high intensity electric field was formed at the disc circumferential area, which provided a constant electric field for the production of uniform nanofibers. The spinning solution, spinning speed of metal wire, and winding speed were found to play an important role in producing good quality nanofiber yarns, in terms of morphology, strength, and productivity. Pure nanofiber yarns were obtained after dissolving the core yarns in a proper solvent. This method has shown potential for the mass production of nanofiber yarns for industrial applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mass production of nanofibers is crucial in both laboratory research and industry application of nanofibers. In this study, multiple ring spinnerets have been used to generate needleless electrospinning. Multiple polymer jets were produced from the top of each ring in the spinning process, resulting in thin and uniform nanofibers. Production rate of nanofibers increased gradually with the increase of the number of rings in the spinneret. Spinning performance of multiple ring electrospinning, namely the quality and production rate of the as-spun nanofibers, was dependent on experimental parameters like applied voltage and polymer concentration. Electric field analysis of multiple ring showed that high concentrated electric field was formed on the surface of each ring. Fiber diameter together with production rate of needleless electrospinning was dependent on the strength and distribution of the electric field of the spinneret. Needleless electrospinning from multiple ring can be further applied in both laboratory research and industry where large amount of nanofibers must be employed simultaneously. © 2014 The Korean Fiber Society and Springer Science+Business Media Dordrecht.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quantification of programmed and accidental cell death provides useful end-points for the anticancer drug efficacy assessment. Cell death is, however, a stochastic process. Therefore, the opportunity to dynamically quantify individual cellular states is advantageous over the commonly employed static, end-point assays. In this work, we describe the development and application of a microfabricated, dielectrophoretic (DEP) cell immobilization platform for the realtime analysis of cancer drug-induced cytotoxicity. Microelectrode arrays were designed to generate weak electro-thermal vortices that support efficient drug mixing and rapid cell immobilization at the delta-shape regions of strong electric field formed between the opposite microelectrodes. We applied this technology to the dynamic analysis of hematopoietic tumor cells that represent a particular challenge for real-time imaging due to their dislodgement during image acquisition. The present study was designed to provide a comprehensive mechanistic rationale for accelerated cell-based assays on DEP chips using real-time labeling with cell permeability markers. In this context, we provide data on the complex behavior of viable vs dying cells in the DEP fields and probe the effects of DEP fields upon cell responses to anticancer drugs and overall bioassay performance. Results indicate that simple DEP cell immobilization technology can be readily applied for the dynamic analysis of investigational drugs in hematopoietic cancer cells. This ability is of particular importance in studying the outcome of patient derived cancer cells, when exposed to therapeutic drugs, as these cells are often rare and difficult to collect, purify and immobilize.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents design and simulation of a circular meander dipole antenna at the industrial, scientific, and medical band of 915 MHz for energy scavenging in a passive head-mountable deep brain stimulation device. The interaction of the proposed antenna with a rat body is modeled and discussed. In the antenna, the radiating layer is meandered, and a FR-4 substrate is used to limit the radius and height of the antenna to 14 mm and 1.60 mm, respectively. The resonance frequency of the designed antenna is 915 MHz and the bandwidth of 15 MHz at a return loss of -10 dB in free space. To model the interaction of the antenna with a rat body, two aspects including functional and biological are considered. The functional aspect includes input impedance, resonance frequency, gain pattern, radiation efficiency of the antenna, and the biological aspect involves electric field distribution, and SAR value. A complete rat model is used in the finite difference time domain based EM simulation software XFdtd. The simulated results demonstrate that the specific absorption rate distributions occur within the skull in the rat model, and their values are higher than the standard regulated values for the antenna receiving power of 1W.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study is to design a low-cost planar Archimedean dipole antenna for batteryless transcranial direct current stimulation devices. The antenna parameters including resonance frequency, radiation efficiency, radiation pattern, and gain are simulated using finite difference time domain based electromagnetic simulation software XFdtd. The proposed antenna is simulated with low-cost FR4 PCB substrate of thickness of 1.6 mm. The antenna is designed with half wavelength of resonant frequency and fed with a matching line. The target frequency band is the industrial, scientific and medical (ISM) band of 915 MHz which is in the simulated band width of 31 MHz (903-934MHz). Moreover, since the bio-effect of specific absorption rate by radio frequency electromagnetic wave for power harvesting is an important concern, we try to find out the safety limit. Thus a quantitative analysis of distributions of electric field and power absorption in anatomical human head model by the far field radio frequency energy received by our designed antenna has been presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents systematic studies on aligning carbon nanofillers in epoxy by external fields, either electric fields or magnetic fields, to create nanocomposites with greatly improved mechanical and electrical properties. Carbon nanofibers (CNFs) and graphene nanoplatelets (GnPs) were observed to align along the field direction in the epoxy resin. Compared to the unmodifed epoxy and those with randomly-oriented carbon nanofillers, the nanocomposites with aligned carbon nanofillers showed significantly higher fracture toughness and electrical conductivity along the direction of the external field. Compared with randomly-oriented nanofillers, aligned GnPs and CNFs produced 40% and 27% improvement in fracture energy at 1.0 wt%, bringing the total increase in fracture energy over the neat polymer to more than 10 times. Several key toughening mechanisms were identified through fractographic analysis, which was used to develop predictive models to quantify the increases in the value of GIc as a result of 1-D and 2D carbon nanofillers. The present findings suggest that aligning carbon nanofillers presents a very promising technique to create multi-scale reinforcement with greatly increased electric conductivity and fracture toughness.