It is an open-ended challenge to accurately detect the epileptic seizures through electroencephalogram (EEG) signals. Recently published studies have made elaborate attempts to distinguish between the normal and epileptic EEG signals by advanced nonlinear entropy methods, such as the approximate entropy, sample entropy, fuzzy entropy, and permutation entropy, etc. Most recently, a novel distribution entropy (DistEn) has been reported to have superior performance compared with the conventional entropy methods for especially short length data. We thus aimed, in the present study, to show the potential of DistEn in the analysis of epileptic EEG signals. The publicly-accessible Bonn database which consisted of normal, interictal, and ictal EEG signals was used in this study. Three different measurement protocols were set for better understanding the performance of DistEn, which are: i) calculate the DistEn of a specific EEG signal using the full recording; ii) calculate the DistEn by averaging the results for all its possible non-overlapped 5 second segments; and iii) calculate it by averaging the DistEn values for all the possible non-overlapped segments of 1 second length, respectively. Results for all three protocols indicated a statistically significantly increased DistEn for the ictal class compared with both the normal and interictal classes. Besides, the results obtained under the third protocol, which only used very short segments (1 s) of EEG recordings showed a significantly (p <; 0.05) increased DistEn for the interictal class in compassion with the normal class, whereas both analyses using relatively long EEG signals failed in tracking this difference between them, which may be due to a nonstationarity effect on entropy algorithm. The capability of discriminating between the normal and interictal EEG signals is of great clinical relevance since it may provide helpful tools for the detection of a seizure onset. Therefore, our study suggests that the DistEn analysis of EEG signals is very promising for clinical and even portable EEG monitoring.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper introduces a method to classify EEG signals using features extracted by an integration of wavelet transform and the nonparametric Wilcoxon test. Orthogonal Haar wavelet coefficients are ranked based on the Wilcoxon test’s statistics. The most prominent discriminant wavelets are assembled to form a feature set that serves as inputs to the naïve Bayes classifier. Two benchmark datasets, named Ia and Ib, downloaded from the brain–computer interface (BCI) competition II are employed for the experiments. Classification performance is evaluated using accuracy, mutual information, Gini coefficient and F-measure. Widely used classifiers, including feedforward neural network, support vector machine, k-nearest neighbours, ensemble learning Adaboost and adaptive neuro-fuzzy inference system, are also implemented for comparisons. The proposed combination of Haar wavelet features and naïve Bayes classifier considerably dominates the competitive classification approaches and outperforms the best performance on the Ia and Ib datasets reported in the BCI competition II. Application of naïve Bayes also provides a low computational cost approach that promotes the implementation of a potential real-time BCI system.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The nonlinear, noisy and outlier characteristics of electroencephalography (EEG) signals inspire the employment of fuzzy logic due to its power to handle uncertainty. This paper introduces an approach to classify motor imagery EEG signals using an interval type-2 fuzzy logic system (IT2FLS) in a combination with wavelet transformation. Wavelet coefficients are ranked based on the statistics of the receiver operating characteristic curve criterion. The most informative coefficients serve as inputs to the IT2FLS for the classification task. Two benchmark datasets, named Ia and Ib, downloaded from the brain-computer interface (BCI) competition II, are employed for the experiments. Classification performance is evaluated using accuracy, sensitivity, specificity and F-measure. Widely-used classifiers, including feedforward neural network, support vector machine, k-nearest neighbours, AdaBoost and adaptive neuro-fuzzy inference system, are also implemented for comparisons. The wavelet-IT2FLS method considerably dominates the comparable classifiers on both datasets, and outperforms the best performance on the Ia and Ib datasets reported in the BCI competition II by 1.40% and 2.27% respectively. The proposed approach yields great accuracy and requires low computational cost, which can be applied to a real-time BCI system for motor imagery data analysis.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

EEG signal is one of the most important signals for diagnosing some diseases. EEG is always recorded with an amount of noise, the more noise is recorded the less quality is the EEG signal. The included noise can represent the quality of the recorded EEG signal, this paper proposes a signal quality assessment method for EEG signal. The method generates an automated measure to detect the noise level of the recorded EEG signal. Mel-Frequency Cepstrum Coefficient is used to represent the signals. Hidden Markov Models were used to build a classification model that classifies the EEG signals based on the noise level associated with the signal. This EEG quality assessment measure will help doctors and researchers to focus on the patterns in the signal that have high signal to noise ratio and carry more information. Moreover, our model was applied on an uncontrolled environment and on controlled environment and a result comparison was applied.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Epilepsy is an electrophysiological disorder of the brain, the hallmark of which is recurrent and unprovoked seizures. Electroencephalogram (EEG) measures electrical activity of the brain that is commonly applied as a non-invasive technique for seizure detection. Although a vast number of publications have been published on intelligent algorithms to classify interictal and ictal EEG, it remains an open question whether they can be detected using short-length EEG recordings. In this study, we proposed three protocols to select 5 s EEG segment for classifying interictal and ictal EEG from normal. We used the publicly-accessible Bonn database, which consists of normal, interical, and ictal EEG signals with a length of 4097 sampling points (23.6 s) per record. In this study, we selected three segments of 868 points (5 s) length from each recordings and evaluated results for each of them separately. The well-studied irregularity measure-sample entropy (SampEn)-and a more recently proposed complexity measure-distribution entropy (DistEn)-were used as classification features. A total of 20 combinations of input parameters m and τ for the calculation of SampEn and DistEn were selected for compatibility. Results showed that SampEn was undefined for half of the used combinations of input parameters and indicated a large intra-class variance. Moreover, DistEn performed robustly for short-length EEG data indicating relative independence from input parameters and small intra-class fluctuations. In addition, it showed acceptable performance for all three classification problems (interictal EEG from normal, ictal EEG from normal, and ictal EEG from interictal) compared to SampEn, which showed better results only for distinguishing normal EEG from interictal and ictal. Both SampEn and DistEn showed good reproducibility and consistency, as evidenced by the independence of results on analysing protocol.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

An automated signal quality assessment method was proposed for the EEG signals, which will help in testing new BCI algorithms so that the testing can be made on high quality signals only. This research includes the development of novel feature extraction technique and a new clustering algorithm for EEG signals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The noninvasive brain imaging modalities have provided us an extraordinary means for monitoring the working brain. Among these modalities, Electroencephalography (EEG) is the most widely used technique for measuring the brain signals under different tasks, due to its mobility, low cost, and high temporal resolution. In this paper we investigate the use of EEG signals in brain-computer interface (BCI) systems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper introduces an approach to classify EEG signals using wavelet transform and a fuzzy standard additive model (FSAM) with tabu search learning mechanism. Wavelet coefficients are ranked based on statistics of the Wilcoxon test. The most informative coefficients are assembled to form a feature set that serves as inputs to the tabu-FSAM. Two benchmark datasets, named Ia and Ib, downloaded from the brain-computer interface (BCI) competition II are employed for the experiments. Classification performance is evaluated using accuracy, mutual information, Gini coefficient and F-measure. Widely-used classifiers, including feedforward neural network, support vector machine, k-nearest neighbours, ensemble learning Adaboost and adaptive neuro-fuzzy inference system, are also implemented for comparisons. The proposed tabu-FSAM method considerably dominates the competitive classifiers, and outperforms the best performance on the Ia and Ib datasets reported in the BCI competition II.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

 Luke's work addresses issue of robustly attenuating multi-source noise from surface EEG signals using a novel Adaptive-Multiple-Reference Least-Means-Squares filter (AMR-LMS). In practice, the filter successfully removes electrical interference and muscle noise generated during movement which contaminates EEG, allowing subjects to maintain maximum mobility throughout signal acquisition and during the use of a Brain Computer Interface.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Brain Computer Interface (BCI) is playing a very important role in human machine communications. Recent communication systems depend on the brain signals for communication. In these systems, users clearly manipulate their brain activity rather than using motor movements in order to generate signals that could be used to give commands and control any communication devices, robots or computers. In this paper, the aim was to estimate the performance of a brain computer interface (BCI) system by detecting the prosthetic motor imaginary tasks by using only a single channel of electroencephalography (EEG). The participant is asked to imagine moving his arm up or down and our system detects the movement based on the participant brain signal. Some features are extracted from the brain signal using Mel-Frequency Cepstrum Coefficient and based on these feature a Hidden Markov model is used to help in knowing if the participant imagined moving up or down. The major advantage in our method is that only one channel is needed to take the decision. Moreover, the method is online which means that it can give the decision as soon as the signal is given to the system. Hundred signals were used for testing, on average 89 % of the up down prosthetic motor imaginary tasks were detected correctly. This method can be used in many different applications such as: moving artificial prosthetic limbs and wheelchairs due to it's high speed and accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Brain Computer Interface (BCI) plays an important role in the communication between human and machines. This communication is based on the human brain signals. In these systems, users use their brain instead of the limbs or body movements to do tasks. The brain signals are analyzed and translated into commands to control any communication devices, robots or computers. In this paper, the aim was to enhance the performance of a brain computer interface (BCI) systems through better prosthetic motor imaginary tasks classification. The challenging part is to use only a single channel of electroencephalography (EEG). Arm movement imagination is the task of the user, where (s)he was asked to imagine moving his arm up or down. Our system detected the imagination based on the input brain signal. Some EEG quality features were extracted from the brain signal, and the Decision Tree was used to classify the participant's imagination based on the extracted features. Our system is online which means that it can give the decision as soon as the signal is given to the system (takes only 20 ms). Also, only one EEG channel is used for classification which reduces the complexity of the system which leads to fast performance. Hundred signals were used for testing, on average 97.4% of the up-down prosthetic motor imaginary tasks were detected correctly. This method can be used in many different applications such as: moving artificial limbs and wheelchairs due to it's high speed and accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new method for blind source separation by exploiting phase and frequency redundancy of cyclostationary signals in a complementary way. It requires a weaker separation condition than those methods which only exploit the phase diversity or the frequency diversity of the source signals. The separation criterion is to diagonalize a polynomial matrix whose coefficient matrices consist of the correlation and cyclic correlation matrices, at time delay .TAU. = 0, of multiple measurements. An algorithm is proposed to perform the blind source separation. Computer simulation results illustrate the performance of the new algorithm in comparison with the existing ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper researches seismic signals of typical vehicle targets in order to extract features and to recognize vehicle targets. As a data fusion method, the technique of artificial neural networks combined with genetic algorithm(ANNCGA) is applied for recognition of seismic signals that belong to different kinds of vehicle targets. The technique of ANNCGA and its architecture have been presented. The algorithm had been used for classification and recognition of seismic signals of vehicle targets in the outdoor environment. Through experiments, it can be proven that seismic properties of target acquired are correct, ANNCGA data fusion method is effective to solve the problem of target recognition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new approach for blind separation of unknown cyclostationary signals from instantaneous mixtures. The proposed method can perfectly separate the mixed source signals so long as they have either different cyclic frequencies or clock phases. This is a weaker condition than those required by the algorithms. The separation criterion is to diagonalize a polynomial matrix whose coefficient matrices consist of the correlation and cyclic correlation matrices, at time delay τ=0, of multiple measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new blind equalization algorithm for application to wireless communication employing MPSK signals is proposed in this paper.  Since the new cost function exploits the amplitude and phase information simultaneously, the proposed algorithm can provide a superior performance than the conventional constant modulus algorithm (CMA) which only use the amplitude knowledge in its cost function.  Theoretical analysis and numerical simulations both demonstrate that the steady-state mean square error (MSE) for the proposed algorithm is less than that of the CMA.