8 resultados para Dryness.

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are (at least!) two remarkable things about Australia: one is that it is the driest inhabited continent on the planet and the second that it has the largest houses in the world. The relationship between these two facts serves as one way of understanding its settlement patterns and the character of its suburbs, foregrounding the desires that underpin their cultural economies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Tear meniscus height (TMH) is an indirect measurement of tear film volume. This study investigated the temporal changes in the TMH during the blink interval in the morning (8–9 am) and at the end of the day (5–6 pm) in both soft contact lens (CL) and nonlens wearers (NLW).

Methods: Fifty participants (25 CL; 25 NLW) were evaluated for their subjective symptoms, TMH, noninvasive break up time, and bulbar hyperemia at the am and pm visits on the same day. The TMH was measured at set intervals between 2 and 15 sec during the blink interval, using an optical coherence tomographer.

Results: The NLW group revealed no changes in a variety of symptoms during the day, whereas the CL group reported an increase in dryness (P=0.03) and grittiness (P=0.02) over the day. For both groups, the TMH and calculated tear meniscus volume revealed lower values immediately after the blink and increased progressively afterwards, mainly due to reflex tearing. The am tear meniscus volume values tended to be higher than the pm values for both groups, but this was not significant (NLW P=0.13; CL P=0.82). Noninvasive break up time deteriorated during the day for both groups but was only significant for the CL group (P=0.002), whereas bulbar hyperemia revealed no statistically significant change for either group.

Conclusions: Reflex tearing may play a substantial role in the TMH differences observed over the blink interval. Standardization of the time when a TMH measurement is performed will be valuable in comparing tear film clinical studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the compatibility of a new silicone hydrogel lens, asmofilcon A (with four multipurpose disinfecting solutions: OPTIFREE RepleniSH, ReNu MultiPlus, Solo-Care Aqua and MeniCare Soft). Ocular responses and subjective responses were monitored with each lens-care system combination.

Methods: The study was conducted as a prospective, bilateral, clinical trial with a single-masked investigator, and randomized cross-over design with four phases, (one for each care system). Each study phase comprised of two consecutive days of lens wear where the lenses were inserted on day 1 directly from the blister-packs and worn for over 8 hr, then inserted on day 2 after overnight disinfection with one of the study lens care systems. Twenty-five adapted soft contact lens wearers who were able to wear their habitual lenses comfortably for more than 12 hr were recruited.

Results: There were statistically significant differences in corneal staining found for all the lens-care systems when comparing the results of day 1 (from the blister pack) with day 2 (following care system use) (P < 0.05). ReNu MultiPlus solution had the highest grade for corneal staining at the 2-hr time point on day 2 which then decreased by 6 hr (P < 0.05). There was no difference between the lens care systems and the rating of subjective comfort over either of the two days. The rating of dryness and burning sensations were only slightly increased at 6 hr for all lens care systems except ReNu MultiPlus where burning was highest on insertion (P < 0.05).

Conclusion: Corneal staining observed in this study does not seem to have been related to the presence of polyhexamethylene biguanide (0.0001% wv) that was present in three of the four care systems. Only one care system (ReNu MultiPlus) demonstrated an associated level of corneal staining that was statistically significant; however, this was not considered to be of clinical relevance. These results suggest that using this novel surface-treated silicone hydrogel lens may result in less lens and lens care-related interactions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To clinically evaluate long-term users of two different contact lens care preservative systems and to investigate whether prolonged use is associated with an increase in the prevalence of dry eye.

Methods: Eighty-nine wearers of group IV hydrogel or silicone hydrogel lenses participated in this one-visit, investigator-masked study. Subjects were required to have consistently used a polyhexamethylene biguanide (PHMB) or polyquaternium-1 (PQT) based solution for 2 years. Consistent use was defined as 80% for the past 2 years and 100% for the past year. Clinical assessments included: average and comfortable wear time; overall and end-of-day comfort; signs of dryness, discomfort, burning or stinging, grittiness or scratchiness and visual changes; non-invasive and fluorescein break-up-time; pre-ocular tear film lipids, tear meniscus height, Schirmer and fluorescein clearance tests; limbal and bulbar hyperemia; palpebral roughness; corneal and conjunctival staining; lens front surface wetting; and lens film deposits.

Results: Significantly more grittiness or scratchiness was reported by subjects using a PHMB-containing system (67% vs. 44%; P = 0.02). Palpebral roughness and hyperemia were significantly greater in the PHMB group wearing group IV lenses (P = 0.01 and P = 0.05, respectively). Corneal staining was significantly higher in the PHMB users in all four peripheral sectors (P < 0.01). Nasal and temporal conjunctival staining was also significantly higher for users of PHMB-containing systems (P < 0.05). Front surface lens wettability was significantly better for group IV PQT users compared to PHMB users (P = 0.008), with 84% vs. 72%, respectively, with lenses graded by the investigator as having good or excellent wettability. Significantly higher levels of lens front surface film deposits were noted with PHMB users (P = 0.007), with 58% of group IV lenses treated with PHMB compared with 38% of group IV lenses treated with PQT showing some lens front surface film deposition. No significant differences between the two preservative system groups were noted for the range of dry eye evaluations nor the remaining clinical assessments.

Conclusions: Differences in both ocular and lens characteristic were observed between long-term users of two preservative systems used in many contact lens multi-purpose solutions. The findings from this study did not support the hypothesis that prolonged use of PHMB-containing solutions leads to dry eye. Additional studies including a larger sample size and perhaps longer use of the systems could help to further elucidate differences in clinical performance between systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. To investigate initial comfort and adaptation of currently successful low oxygen transmissibility soft lens wearers refitted with silicone hydrogel (SH) lenses for daily wear.

Methods. Fifty-five subjects were enrolled in a subject-masked 5-month clinical trial in which they wore 5 SH lenses in a randomized, crossover design. Comfort, burning, and dryness were rated on scales of 0 to 100 immediately on insertion and the time for lens settling was recorded. Symptoms were then rated at various times, using BlackBerry wireless communication devices (Research in Motion, Waterloo, Canada), during the day for 2 cycles of 2 weeks wear for each lens type.

Results. Comfort immediately on insertion varied between lens types (P=0.002). All lens types were reported by the subjects to have settled within 30 to 45 sec of insertion (P=0.14) and settled comfort was greater than comfort immediately on insertion (P<0.001). Comfort within the first hour of wear also varied between lens types (P=0.02). Comfort during the day decreased significantly for all lenses (P=0.001), but there was no difference between lenses (P=0.19) and no effect of lens age (P=0.15). The wearing times were greater with the SH lenses than the habitual lenses worn before study commencement (P=0.001). Overall performance of the lenses after 4 weeks was high, with no difference between lenses (P=0.45).

Conclusions. Initial comfort and adaptation to all SH lenses were good and no differences in the overall ratings were found between the 5 SH lenses investigated. Decreased comfort was noted later in the day with all lens types, but longer wearing times were reported with the SH lenses than previous hydroxyethyl methacrylate-based lenses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate subjective ocular comfort across the day with three silicone hydrogel daily disposables (SHDDs) in a group of adapted lens wearers. Masked subjects (asymptomatic or symptomatic of end-of-day (EOD) dryness with habitual lenses) wore three SHDDs: DAILIES TOTAL1 (DT1), Clariti 1day (C1D), or 1-DAY ACUVUE TRUEYE (AVTE), each for 3 days. On day 2, wearing time (WT) and comfort ratings after insertion, at 4, 8, and 12 hours, and at EOD were recorded. Because not all subjects wore lenses for 12 hours, comfort was analyzed across the day (up to 8 hours, 8 to 12 hours), and a new variable (“cumulative comfort” [CC]) was calculated for EOD. One hundred four subjects completed the study (51 asymptomatic, 53 symptomatic). The two groups had different WTs (mean WT, 14.0 and 12.7 hours, respectively; p < 0.001). Ocular comfort was rated higher in the asymptomatic group throughout the day (p < 0.001). One hundred four subjects wore all three SHDDs for at least 8 hours, whereas 74 (45 asymptomatic, 29 symptomatic) subjects wore them for 12 hours or longer. Comfort ratings were higher with DT1 (least square means [LSM] = 91.0) than with C1D (LSM = 86.5; p < 0.001) and AVTE (LSM = 87.7; p = 0.011) for the first 8 hours and lower with C1D compared with DT1 (p = 0.012) from 8 to 12 hours. Mean EOD (± SD) comfort with the C1D lens was 72 ± 21, lower than both DT1 (mean, 79 ± 17; p = 0.001) and AVTE (mean, 78 ± 21; p = 0.010). Mean CC was higher in the asymptomatic group (mean, 1261 ± 59) compared with that in the symptomatic group (mean, 1009 ± 58; p < 0.001) and higher for DT1 (mean, 1184 ± 258) than C1D (mean, 1094 ± 318; p = 0.002) and AVTE (mean, 1122 ± 297; p = 0.046). All three SHDDs had average WTs of 12 hours or longer for 1 day. Comfort during the first 12 hours was highest with DT1 (similar to AVTE between 8 and 12 hours) and lowest with C1D. End-of-day comfort was lowest with C1D, and CC was highest for DT1. Cumulative comfort may be a valuable new metric to assess ocular comfort during the day.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Discontinuation or “dropout” from contact lens (CL) wear continues to afflict the CL industry. This study was conducted to determine whether the advent of new CL materials and designs has impacted the dropout rate and the reasons for discontinuation. Current and lapsed CL wearers residing in Canada were recruited using Facebook to take part in an on line survey investigating CL wearing experiences during 2008 to 2010 and to establish the percentage of participants who temporarily and permanently discontinued CL wear during the period surveyed. Four thousand two hundred seven eligible surveys were received (64% female; median age 27 years). Forty percent had lapsed from lens wear for at least 4 months; however, 62% of the lapsed wearers (LWs) resumed wear. There were no differences between LWs and nonlapsed wearers (NLWs) with respect to gender; however, LWs were older, started lens wear when older, and had not worn lenses for as long as NLWs (all P<0.001). More NLWs than LWs wore silicone hydrogel CLs (49% vs. 38%, P<0.001) and more LWs than NLWs wore daily disposable lenses and hydrogel CLs (24% vs. 19% and 22% vs. 18%, respectively, P≤0.001). Primary reasons for discontinuation were discomfort (24%), dryness (20%), red eyes (7%), and expense (7%). Compliance with lens replacement was no different between LWs and NLWs (48% vs. 45%). About 23% of those surveyed had discontinued CL wear permanently. The primary reasons for dropping out continue to be discomfort and dryness. Dropout rates were lower in silicone hydrogel wearers.