11 resultados para DISSIPATIVE COLLISIONS

em Deakin Research Online - Australia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

On-site collision tests of full-scale concrete barriers are an important method to understand what happens to concrete barriers when vehicles collide with them. However, such tests require both time and money, so modeling and simulation of collisions by computer have been developed as an alternative in this research. First, spring subgrade models were developed to formulate the ground boundary of concrete barriers based on previous experiments. Then, the finite element method models were developed for both heavy trucks and concrete barriers to simulate their dynamic collision performances. Comparison of the results generated from computer simulations and on-site experiments demonstrates that the developed models can be applied to simulate the collision of heavy trucks with concrete barriers, to replicate the movement of the truck at the collision, and to investigate the performance of the concrete barriers. The developed research methodology can be widely used to support the design of new concrete barriers and the safety analysis of existing ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Real vehicle collision experiments on full-scale road safety barriers are important to determine the outcome of a vehicle versus barrier impact accident. However, such experiments require large investment of time and money. Numerical simulation has therefore been imperative as an alternative method for testing concrete barriers. In this research, spring subgrade models were first developed to simulate the ground boundary of concrete barriers. Both heavy trucks and concrete barriers were modeled using finite element methods (FEM) to simulate dynamic collision performances. Comparison of the results generated from computer simulations and on-site full-scale experiments demonstrated that the developed models could be applied to simulate the collision of heavy trucks with concrete barriers to provide the data to design new road safety barriers and analyze existing ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dissipative particle dynamics simulation is usually used to study polymer in mesoscopic space. The traditional methods are resource intensive, especially when the scale of research is large. Therefore, improving computing efficiency is a key point in this research area. Two major issues are addressed in this paper. First, the DPD methods are analysed and the most time-consuming parts are identified: conservative force, dissipative force and random force. Second, we describe how to parallelize the existing serial application in the Windows Compute Cluster Server (WCCS) platform. The results show that the parallel algorithm not only effectively shortens the computing time, but also improves the resource utilization rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the development of the simulation of particle dynamics, the traditional dissipative particle dynamics (DPD) method can not satisfy the needs of research in static or dynamic wetting phenomena. However, the Many-body DPD approach extends the ability of the traditional method to simulate the interface between solid and liquid or some other situation. In this paper, we propose a Many-body DPD program to simulate the solid-liquid interface and get satisfactory results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To investigate the risk of falls and motor vehicle collisions (MVCs) in patients with glaucoma.

METHODS. The sample comprised 48 patients with glaucoma (mean visual field mean deviation [MD] in the better eye = −3.9 dB; 5.1 dB SD) and 47 age-matched normal control subjects, who were recruited from a university-based hospital eye care clinic and are enrolled in an ongoing prospective study of risk factors for falls, risk factors for MVCs, and on-road driving performance in glaucoma. Main outcome measures at baseline were previous self-reported falls and MVCs, and police-reported MVCs. Demographic and medical data were obtained. In addition, functional independence in daily living, physical activity level and balance were assessed. Clinical vision measures included visual acuity, contrast sensitivity, standard automated perimetry, useful field of view (UFOV), and stereopsis. Analyses of falls and MVCs were adjusted to account for the possible confounding effects of demographic characteristics, medications, and visual field impairment. MVC analyses were also adjusted for kilometers driven per week.

RESULTS. There were no significant differences between patients with glaucoma and control subjects with respect to number of systemic medical conditions, body mass index, functional independence, and physical activity level (P > 0.10). At baseline, 40 (83%) patients with glaucoma and 44 (94%) control subjects were driving. Compared with control subjects, patients with glaucoma were over three times more likely to have fallen in the previous year (odds ratio [OR]adjusted = 3.71; 95% CI, 1.14–12.05), over six times more likely to have been involved in one or more MVCs in the previous 5 years (ORadjusted = 6.62; 95% CI, 1.40–31.23), and more likely to have been at fault (ORadjusted = 12.44; 95% CI, 1.08–143.99). The strongest risk factor for MVCs in patients with glaucoma was impaired UFOV selective attention (ORadjusted = 10.29; 95% CI, 1.10–96.62; for selective attention >350 ms compared with ≤350 ms).

CONCLUSIONS. There is an increased risk of falls and MVCs in patients with glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a new electrochemical detection approach towards single protein molecules (microperoxidase-11, MP-11), which are attached to the surface of graphene nanosheets. The non-covalently functionalized graphene nanosheets exhibit enhanced electroactive surface area, where amplified redox current is produced when graphene nanosheets collide with the electrode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: Accelerometer peak impact accelerations are being used to measure player physical demands in contact sports. However, their accuracy to do so has not been ascertained. PURPOSE: To compare peak-impact-acceleration data from an accelerometer contained in a wearable tracking device with a 3-dimensional motion-analysis (MA) system during tackling and bumping. METHODS: Twenty-five semielite rugby athletes wore a tracking device containing a 100-Hz triaxial accelerometer (MinimaxX S4, Catapult Innovations, Australia). A single retroreflective marker was attached to the device, with its position recorded by a 12-camera MA system during 3 physical-collision tasks (tackle bag, bump pad, and tackle drill; N = 625). The accuracy, effect size, agreement, precision, and relative errors for each comparison were obtained as measures of accelerometer validity. RESULTS: Physical-collision peak impact accelerations recorded by the accelerometer overestimated (mean bias 0.60 g) those recorded by the MA system (P < .01). Filtering the raw data at a 20-Hz cutoff improved the accelerometer's relationship with MA data (mean bias 0.01 g; P > .05). When considering the data in 9 magnitude bands, the strongest relationship with the MA system was found in the 3.0-g or less band, and the precision of the accelerometer tended to reduce as the magnitude of impact acceleration increased. Of the 3 movements performed, the tackle-bag task displayed the greatest validity with MA. CONCLUSIONS: The findings indicate that the MinimaxX S4 accelerometer can accurately measure physical-collision peak impact accelerations when data are filtered at a 20-Hz cutoff frequency. As a result, accelerometers may be useful to measure physical collisions in contact sports.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe an alternative electrochemical technique to monitor covalent bond formation in real-time using nanoparticle-electrode collisions. The method is based on recognising the redox current when MP-11 functionalised chemical reduced graphene oxide (rGO) nanosheets collide with Lomant's reagent modified gold microelectrode. This facile and highly sensitive monitoring method can be useful for investigating the fundamental of single-molecule reactions.