8 resultados para Cvs

em Deakin Research Online - Australia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although it is important for prospective studies, the reliability of quantitative measures of cervical muscle size on magnetic resonance imaging is not well established. The aim of the current work was to assess the long-term reliability of measurements of cervical muscle size. In addition, we examined the utility of selecting specific sub-regions of muscles at each vertebral level, averaging between sides of the body, and pooling muscles into larger groups. Axial scans from the base of skull to the third thoracic vertebra were performed in 20 healthy male subjects at baseline and 1.5 years later. We evaluated the semi-spinalis capitis, splenius capitis, spinalis cervicis, longus capitis, longus colli, levator scapulae, sternocleidomastoid, anterior scalenes and middle with posterior scalenes. Bland-Altman analysis showed all measurements to be repeatable between testing-days. Reliability was typically best when entire muscle volume was measured (co-efficients of variation (CVs): 3.3-8.1% depending on muscle). However, when the size of the muscle was assessed at specific vertebral levels, similar measurement precision was achieved (CVs: 2.7-7.6%). A median of 4-6 images were measured at the specific vertebral levels versus 18-37 images for entire muscle volume. This would represent considerable time saving. Based on the findings we also recommend measuring both sides of the body and calculating an average value. Pooling specific muscles into the deep neck flexors (CV: 3.5%) and neck extensors (CV: 2.7%) can serve to reduce variability further. The results of the current study help to establish outcome measures for interventional studies and for sample size estimation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Establishing the long-term repeatability of quantitative measures of lumbar intervertebral disc and spinal morphology is important for planning interventional studies. We aimed to examine this issue and to determine to what extent a smaller number of measurements per disc or vertebral level could be used to save operator time without compromising measurement precision. Twenty-one healthy male subjects were scanned at baseline and 1.5 years later. On sagittal MR-scans intervertebral disc cross-sectional area, anterior disc height, posterior disc height, intervertebral angle and intervertebral length were measured. The repeatability of the average value from all sagittal images or from 1, 3, 5 or 7 images centred at the spinous process was evaluated. Bland-Altman analysis showed all measurements to be repeatable between testing days. Intervertebral length was the most precise measurement (coefficients of variation [CVs] between 1.2% and 1.5%), followed by disc cross-sectional area (CVs between 2.9% and 3.6%). Variance component analysis showed that using 7 images, but not 1, 3 or 5 images, resulted in a similar level of measurement error as when measurements from all images were included.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we examine the reliability and validity (in comparison to magnetic resonance imaging; MRI) of real-time ultrasound measures of lumbar erector spinae thickness. We also consider the between-day reliability of the lumbar multifidus muscle area as measured via ultrasound. 23 male subjects aged 21-45 years were measured three times over the course of nine days by one operator. The first (L1) through to the fifth (L5) lumbar vertebral levels were measured on the left and right sides. MRI was performed on the same day as first ultrasound scanning. For between-day intra-rater reliability, intra-class correlation co-efficients (ICCs), standard error of the measurement, minimal detectable difference and co-efficients of variation (CVs) were calculated along with their 95% confidence intervals and Bland-Altman analysis was performed. On Bland-Altman analysis, erector spinae thickness and multifidus area ultrasound measures 'agreed' with equivalent MR measures, though the correlation between MR and ultrasound measures was typically poor to moderate. For both ultrasound measures, the ICCs ranged from 'moderate' to 'excellent' at individual vertebral levels, although multifidus area (CV ranged from 8 to 15%) was less reliable than erector spinae thickness (CV ranged from 6 to 10%). 'Agreement' on Bland-Altmann analysis was present between days for all ultrasound measures. Averaging between sides and between vertebral levels improved reliability. Average erector spinae thickness showed a CV of 5.5% (ICC 0.77) and average multifidus area 6.2% (ICC 0.80).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monitoring the abundances of prey is important for informing the management of threatened and endangered predators. We evaluated the usefulness of faecal counts and distance sampling for monitoring the abundances of rusa deer Rusa timorensis, feral pig Sus scrofa and water buffalo Bubalus bubalis, the three key prey of the Komodo dragon Varanus komodoensis, at 11 sites on five islands in and around Komodo National Park, eastern Indonesia. We used species-specific global detection functions and cluster sizes (i.e. multiple covariates distance sampling) to estimate densities of rusa deer and feral pig, but there were too few observations to estimate densities of water buffalo. Rusa deer densities varied from from 2.5 to 165.5 deer/km2 with coefficients of variation (CVs) of 15-105%. Feral pig densities varied from 0.0 to 25.2 pigs/km 2 with CVs of 25-106%. There was a positive relationship between estimated faecal densities and estimated population densities for both rusa deer and feral pig: the form of the relationship was non-linear for rusa deer, but there was similar support for linear and non-linear relationships for feral pig. We found that faecal counts were more useful when ungulate densities were too low to estimate densities with distance sampling. Faecal count methods were also easier for field staff to conduct than distance sampling. Because spatial and temporal variation in ungulate density is likely to influence the population dynamics of the Komodo dragon, we recommend that annual monitoring of ungulates in and around Komodo National Park be undertaken using distance sampling and faecal counts. The relationships reported here will also be useful for managers establishing monitoring programmes for feral pig, rusa deer and water buffalo elsewhere in their native and exotic ranges.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multicore processors are widely used in today's computer systems. Multicore virtualization technology provides an elastic solution to more efficiently utilize the multicore system. However, the Lock Holder Preemption (LHP) problem in the virtualized multicore systems causes significant CPU cycles wastes, which hurt virtual machine (VM) performance and reduces response latency. The system consolidates more VMs, the LHP problem becomes worse. In this paper, we propose an efficient consolidation-aware vCPU (CVS) scheduling scheme on multicore virtualization platform. Based on vCPU over-commitment rate, the CVS scheduling scheme adaptively selects one algorithm among three vCPU scheduling algorithms: co-scheduling, yield-to-head, and yield-to-tail based on the vCPU over-commitment rate because the actions of vCPU scheduling are split into many single steps such as scheduling vCPUs simultaneously or inserting one vCPU into the run-queue from the head or tail. The CVS scheme can effectively improve VM performance in the low, middle, and high VM consolidation scenarios. Using real-life parallel benchmarks, our experimental results show that the proposed CVS scheme improves the overall system performance while the optimization overhead remains low.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilization of l-ascorbic acid (⌊-AA) is a challenging task for food and pharmaceutical industries. The study was conducted to prepare monodisperse aqueous microspheres containing enhanced concentrations of ⌊-AA by using microchannel emulsification (MCE). The asymmetric straight-through microchannel (MC) array used here constitutes 11 × 104 μm microslots connected to a 10 μm circular microholes. 5-30% (w/w) ⌊-AA was added to a Milli-Q water solution containing 2% (w/w) sodium alginate and 1% (w/w) magnesium sulfate, while the continuous phase constitutes 5% (w/w) tetraglycerol condensed ricinoleate in water-saturated decane. Monodisperse aqueous microspheres with average diameters (dav) of 18.7-20.7 μm and coefficients of variation (CVs) below 6% were successfully prepared via MCE regardless of the ⌊-AA concentrations applied. The collected microspheres were physically stable in terms of their dav and CV for >10 days of storage at 40°C. The aqueous microspheres exhibited ⌊-AA encapsulation efficiency exceeding 70% during the storage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stabilizing l-ascorbic acid is a challenge for food industries. The present study aimed to formulate monodisperse food-grade water-in-oil-in-water (W/O/W) emulsions containing a high concentration of l-ascorbic acid in an inner aqueous phase using homogenization and subsequent microchannel emulsification (MCE). The microchannel (MC) array plate used here was a silicon asymmetric straight-through MC array that consists of numerous 10. μm. ×. 100. μm microslots with a 30. μm depth, each connected to a 10. μm-diameter circular MC with a 70. μm depth. Water-in-oil (W/O) emulsions contained a soybean oil solution with 4-8% (w/w) tetraglycerin condensed ricinoleic acid ester as a continuous phase and an aqueous solution with 10-30% (w/v) l-ascorbic acid, 1% (w/w) magnesium sulfate, and 1% (w/v) gelatin as an inner aqueous phase. The W/O emulsion droplets formulated using a rotor-starter homogenizer had average droplet diameters of 2.6-2.9. μm and coefficients of variation (CVs) of 13-17%. MCE was performed using a dispersed W/O emulsion phase and a 5. mM phosphate buffer containing 1% (w/w) decaglycerol monolaurate and 10-30% (w/v) D(+)-glucose as an outer aqueous phase. Monodisperse W/O/W emulsions containing W/O droplets with average diameters of 26.0-31.5. μm and CVs below 10% were successfully formulated via an asymmetric straight-through MC array at a low hydrophobic emulsifier concentration, regardless of l-ascorbic acid concentration. The W/O droplets dispersed in these monodisperse W/O/W emulsions were physically stable in variation of average diameter and CV for more than 10d of storage at 4. °C. The monodisperse W/O/W emulsions also exhibited l-ascorbic acid retention exceeding 80% during storage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study sought to encapsulate a high concentration of L-ascorbic acid, up to 30% (w/v), in the inner aqueous phase of water-in-oil-water (W/O/W) emulsions with soybean oil as the oil phase. Two-step homogenization was conducted to prepare W/O/W emulsions stabilized by a hydrophobic emulsifier and 30% (v/v) of W/O droplets stabilized by a hydrophilic emulsifier. First-step homogenization prepared W/O emulsions with an average aqueous droplet diameter of 2.0 to 3.0 μm. Second-step homogenization prepared W/O/W emulsions with an average W/O droplet diameter of 14 to 18 μm and coefficients of variation (CVs) of 18% to 25%. The results indicated that stable W/O/W emulsions containing a high concentration of L-ascorbic acid were obtained by adding gelatin and magnesium sulfate in the inner aqueous phase and glucose in both aqueous phases. L-Ascorbic acid retention in the W/O/W emulsions was 40% on day 30 and followed first-order kinetics.